Lahouari Cheded

Lahouari Cheded

Auto-generated profile, based on publicly available information

Lahouari Cheded

Independent Researcher and Consultant, Life SMIEEE, UK

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2020 in IEEE Access
Verified
Journal Article
Open access
MVMati-Ur-Rasool Ashraf Virk
Mati-Ur-Rasool Ashraf Virk
MMMuhammad Faizan Mysorewala
Muhammad Faizan Mysorewala
LCLahouari Cheded
Lahouari Cheded
IAIbrahim Mohamed Ali
Ibrahim Mohamed Ali
Wireless sensor networks (WSN) provide a powerful solution to the task of monitoring the operational conditions of buried and non-buried pipes of different lengths and materials. Due to the limited energy stored in the sensor nodes, the use of low-power vibration sensors becomes the preferred choice. However, the monitoring of vibrations for leak detection in wall-mounted pipelines, and the associated complexities are not adequately dealt with in the literature. This article offers to fill this gap by presenting a feasibility study of leak detection in wall-mounted water pipelines through vibrations measurements using low-power accelerometers. The work is divided into two steps: Firstly, a careful analysis is performed to understand the effect of various fittings such as clamps, bends, and leaks of various sizes, on the vibrations produced. Then this knowledge is used to find the best locations for placement of nodes in order to efficiently detect leaks of various sizes. This analysis revealed two important facts: (a) difficulty in detecting medium-size leaks as their vibrations and those from the no-leak condition are very indistinguishable, (b) vibrations measured away from the leak are of a small benefit to the leak detection process. Consequently, 3 different learning models are applied, all fed with information from multiple nodes, in order to reliably detect leaks and classify their size. Comparing the performances of these models shows that the Support Vector Machine (SVM)-based model gives the best results, in that for the worst case of medium-size leaks and with the use of one sensor, the worst accuracies for leak detection and leak size classification have remarkably been improved from being respectively 51% and 36% with one sensor, to being 88% and 93%, respectively, with only a moderate increase in the number of sensors to four.

1 October 2021 in Process Safety and Environmental Protection
Verified
Journal Article
Closed access
LCLahouari Cheded
Lahouari Cheded
RDRajamani Doraiswami
Rajamani Doraiswami

1 May 2011 in Digital Signal Processing
Verified
Journal Article
Closed access
MOMusa U. Otaru
Musa U. Otaru
AZAzzedine Zerguine
Azzedine Zerguine
LCLahouari Cheded
Lahouari Cheded

6 December 2014 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
YSYasir A. Siddiqui
Yasir A. Siddiqui
ASAbdul-Wahid Abdul-Aziz Saif
Abdul-Wahid Abdul-Aziz Saif
LCLahouari Cheded
Lahouari Cheded
MEMoustafa Elshafei
Moustafa Elshafei
ARAbdur Rahim
Abdur Rahim

2 March 2018 in IET Control Theory & Applications
Verified
Journal Article
Open access
PDF file
RDRajamani Doraiswami
Rajamani Doraiswami
LCLahouari Cheded
Lahouari Cheded
A novel direct identification using the residual model of Kalman filter (KF) is proposed for multiple‐input and multiple‐output Box–Jenkins model of the system formed of the signal and disturbance models using the residual model relating the input and output of the system without any a priori knowledge of the statistics of the disturbance and measurement noise corrupting the output. To avoid a non‐linear optimisation, the auto‐regressive and moving average (MA) residual model is approximated by a high‐order MA model, so that the unknown parameters of the KF enter the residual model linearly. A key property of the KF is established, namely that the transfer matrix of the signal model is the matrix fraction description (MFD) model relating the residual and the system input and output. A two‐stage identification method is developed here. In stage 1, a high‐order KF of the system is identified using the robust, and computationally efficient least‐squares method to capture completely both the signal and disturbance models. In stage 2, the KF for the signal is derived using the balanced model reduction technique. The signal model is derived using the key MFD property. The performance of the proposed scheme is successfully evaluated on both simulated and physical systems.

15 November 2017 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
NSNajam Us Saqib
Najam Us Saqib
MMMuhammad Faizan Mysorewala
Muhammad Faizan Mysorewala
LCLahouari Cheded
Lahouari Cheded
In this paper, we propose a novel monitoring strategy for a wireless sensor networks (WSNs)-based water pipeline network. Our strategy uses a multi-pronged approach to reduce energy consumption based on the use of two types of vibration sensors and pressure sensors, all having different energy levels, and a hierarchical adaptive sampling mechanism to determine the sampling frequency. The sampling rate of the sensors is adjusted according to the bandwidth of the vibration signal being monitored by using a wavelet-based adaptive thresholding scheme that calculates the new sampling frequency for the following cycle. In this multimodal sensing scheme, the duty-cycling approach is used for all sensors to reduce the sampling instances, such that the high-energy, high-precision (HE-HP) vibration sensors have low duty cycles, and the low-energy, low-precision (LE-LP) vibration sensors have high duty cycles. The low duty-cycling (HE-HP) vibration sensor adjusts the sampling frequency of the high duty-cycling (LE-LP) vibration sensor. The simulated test bed considered here consists of a water pipeline network which uses pressure and vibration sensors, with the latter having different energy consumptions and precision levels, at various locations in the network. This is all the more useful for energy conservation for extended monitoring. It is shown that by using the novel features of our proposed scheme, a significant reduction in energy consumption is achieved and the leak is effectively detected by the sensor node that is closest to it. Finally, both the total energy consumed by monitoring as well as the time to detect the leak by a WSN node are computed, and show the superiority of our proposed hierarchical adaptive sampling algorithm over a non-adaptive sampling approach.