Abhijit Dasgupta

Abhijit Dasgupta

Auto-generated profile, based on publicly available information

Abhijit Dasgupta

School of Electrical Engineering, KIIT University, Bhubaneswar

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2015 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
JNJ. Nanda
J. Nanda
sreedhar Madichettysreedhar Madichetty
sreedhar Madichetty
ADAbhijit Dasgupta
Abhijit Dasgupta

17 November 2015 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
sreedhar Madichettysreedhar Madichetty
sreedhar Madichetty
ADAbhijit Dasgupta
Abhijit Dasgupta
SMSambeet Mishra
Sambeet Mishra
CPChinmoy Kumar Panigrahi
Chinmoy Kumar Panigrahi
GBGhouse Basha
Ghouse Basha
In a modular multilevel converter (MMC), the second and other even-order harmonics in the circulating currents are mainly due to the fluctuations in the capacitor voltages in the sub modules of the MMC. The increased circulating currents affect the system performance and threatens the safety operation of power devices. To mitigate the circulating currents, this article puts forward the application of an advanced repetitive controller with alternate phase opposition and disposition pulse-width modulation technique. The proposed controller was operated in tandem with a proportional integral controller for better results of circulating current harmonic suppression and then the stability analysis was analyzed by the Popov criteria. This method is very simple to implement and suitable for multiple harmonic mitigation. Computer simulations and experimental results on a prototype shows that the proposed controller is effective and easy to implement for MMCs.

1 March 2017 in Energy Procedia
Verified
Journal Article
Open access
PNPrabhash Nanda
Prabhash Nanda
CPC.K. Panigrahi
C.K. Panigrahi
ADAbhijit Dasgupta
Abhijit Dasgupta

1 December 2014 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
sreedhar Madichettysreedhar Madichetty
sreedhar Madichetty
ADAbhijit Dasgupta
Abhijit Dasgupta
SMSambeet Mishra
Sambeet Mishra
The multilevel converter has been brought into limelight in this study; however, particular attention has been provided to the form and function of modular multilevel converter (MMC) with new controller to mitigate the circulating currents and harmonics present in the system. Till date, research in this field is very limited with circulating currents and harmonics as the major problem. The stability analysis of proposed controller has been derived and analysed with its experimental results. The system is examined before and after application of controller and results is analysed. This article effectively addresses the problem with prototype of 1 KVA implementation and attempts to make a detailed analysis with their functions in comprehensive manner with HVDC application under different conditions. Also, the applicability of zero voltage switching at turn on, zero current transition at turn off has been verified experimentally. Computer simulations and experiment on a 50 Hz power supply show that the new controller is effective and easy to implement for modular multilevel inverters.

1 April 2017
Verified
Conference Paper
Closed access
SAShobha Agarwal
Shobha Agarwal
ASAleena Swetapadma
Aleena Swetapadma
CPChinmoy Panigrahi
Chinmoy Panigrahi
ADAbhijit Dasgupta
Abhijit Dasgupta
Line commutated converter based high voltage transmission line fault current rises instantly due to the absence of inductance as which is present in ac. In dc currents there is no natural current zero so interruption of current is difficult and therefore the focus of the paper is to identify the fault in less time so that trip command can be initiated to the dc breaker. The dc lines are economical for long length so at far end distance fault identification is essential. The converter control in dc transmission lines control the power and provides synchronous interconnection between two ac systems. The discrete Fourier transform is used to extract the dc current at rectifier end of the dc transmission line and the processed current is compared with the threshold value to identify the fault. The factors considering the effect of fault location and fault resistance are considered for the accuracy, reliability and selectivity.

21 February 2014 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Closed access
sreedhar Madichettysreedhar Madichetty
sreedhar Madichetty
ADAbhijit Dasgupta
Abhijit Dasgupta
Modular Multilevel Converters Part-I: A Review on Topologies, Modulation, Modeling and Control Schemes