Jenna L. Rickus

Jenna L. Rickus

Auto-generated profile, based on publicly available information

Jenna L. Rickus

Purdue Univ. (United States)

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2011 in Nanotechnology
Verified
Journal Article
Closed access
JSJin Shi
Jin Shi
Jonathan ClaussenJonathan Claussen
Jonathan Claussen
Eric McLamoreEric McLamore
Eric McLamore
AHAeraj Ul Haque
Aeraj Ul Haque
DJDavid Jaroch
David Jaroch
D. Marshall PorterfieldD. Marshall Porterfield
D. Marshall Porterfield
This work addresses the comparison of different strategies for improving biosensor performance using nanomaterials. Glucose biosensors based on commonly applied enzyme immobilization approaches, including sol-gel encapsulation approaches and glutaraldehyde cross-linking strategies, were studied in the presence and absence of multi-walled carbon nanotubes (MWNTs). Although direct comparison of design parameters such as linear range and sensitivity is intuitive, this comparison alone is not an accurate indicator of biosensor efficacy, due to the wide range of electrodes and nanomaterials available for use in current biosensor designs. We proposed a comparative protocol which considers both the active area available for transduction following nanomaterial deposition and the sensitivity. Based on the protocol, when no nanomaterials were involved, TEOS/GOx biosensors exhibited the highest efficacy, followed by BSA/GA/GOx and TMOS/GOx biosensors. A novel biosensor containing carboxylated MWNTs modified with glucose oxidase and an overlying TMOS layer demonstrated optimum efficacy in terms of enhanced current density (18.3 ± 0.5 µA mM(-1) cm(-2)), linear range (0.0037-12 mM), detection limit (3.7 µM), coefficient of variation (2%), response time (less than 8 s), and stability/selectivity/reproducibility. H(2)O(2) response tests demonstrated that the most possible reason for the performance enhancement was an increased enzyme loading. This design is an excellent platform for versatile biosensing applications.


26 April 2011 in ACS Nano
Verified
Journal Article
Closed access
TCTae-Gon Cha
Tae-Gon Cha
BBBenjamin A. Baker
Benjamin A. Baker
MSM. Dane Sauffer
M. Dane Sauffer
JSJanette Salgado
Janette Salgado
DJDavid Jaroch
David Jaroch
Jong Hyun ChoiJong Hyun Choi
Jong Hyun Choi

1 October 2015 in Tissue Engineering Part A
Verified
Journal Article
Closed access
MHMarisol Herrera-Perez
Marisol Herrera-Perez
SVSherry Voytik-Harbin
Sherry Voytik-Harbin
JRJenna L. Rickus
Jenna L. Rickus
Diffuse infiltration across brain tissue is a hallmark of glioblastoma and the main cause of unsuccessful total resection that leads to tumor reappearance. A subpopulation termed glioblastoma stem cells (GSCs) has been directly related to aggressive invasion; nonetheless, their migratory characteristics and regulation by the microenvironment are still unknown. Here, we developed a composite matrix of hyaluronan structurally supported by a collagen-oligomer fibril network to simulate the brain-tumor extracellular matrix composition. Matrigel-coated microfibers were embedded within the matrix to create a tunable dual-niche microenvironment that resembles the vascular network of the brain. This model was compared with the most commonly used in vitro three-dimensional (3D) culture formats, Matrigel and collagen type-I monomer matrices, to study how the mechanical and compositional properties of the extracellular matrix (ECM) alter the migration characteristics of GSC neurospheres. The migration mode, distance, velocity, and morphology of the GSCs were monitored over a 72-hour period. The cells altered their migration mode depending on the matrix composition, showing migration by expansive growth in Matrigel matrices, multicellular extension along rigid interfaces (as Matrigel-glass and coated microfibers) and mesenchymal single-cell migration in collagen matrices. Velocity and distance of migration within each composition varied according to matrix mechanical properties. In the dual niche system, the presence of hyaluronan reduced velocity and number of migratory cells; however, cells that came in contact with the pseudo-vessels exhibited collective migration by extensive strand and reached higher velocities than cells migrating individually across the 3D matrix. Our results show that GSCs adopt varied migration mechanisms to invade multiple ECM microenvironments and the migration characteristics exhibited are highly influenced by the matrix physical properties. Moreover, GSC neurospheres exhibit concomitant single and collective migration as a function of the microenvironment topography in order to reach the most productive migration strategy.

20 September 2007 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
SJSabrina S. Jedlicka
Sabrina S. Jedlicka
JRJenna L. Rickus
Jenna L. Rickus
DZDmitry Y. Zemlyanov
Dmitry Y. Zemlyanov

27 August 2009 in Biomacromolecules
Verified
Journal Article
Closed access
TSThomas R. Stratton
Thomas R. Stratton
JRJenna L. Rickus
Jenna L. Rickus
JYJeffrey P. Youngblood
Jeffrey P. Youngblood