Rachel Rubino

Rachel Rubino

Auto-generated profile, based on publicly available information

Rachel Rubino

Cold spring harbor laboratory, cold spring harbor, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2022 in Nature Neuroscience
Verified
Journal Article
Closed access
PDF file
AFAlessandro Furlan
Alessandro Furlan
ACAlberto Corona
Alberto Corona
SBSara Boyle
Sara Boyle
RSRadhashree Sharma
Radhashree Sharma
RRRachel Rubino
Rachel Rubino
BLBo Li
Bo Li

16 March 2020
Verified
Conference Paper
Closed access
PDF file
LYLauren Yates
Lauren Yates
LCLaura Connolly
Laura Connolly
AJAmoon Jamzad
Amoon Jamzad
MAMark Asselin
Mark Asselin
RRRachel Rubino
Rachel Rubino
GFGabor Fichtinger
Gabor Fichtinger
PURPOSE: Raman spectroscopy is an optical imaging technique used to characterize tissue via molecular analysis. The use of Raman spectroscopy for real-time intraoperative tissue classification requires fast analysis with minimal human intervention. In order to have accurate predictions and classifications, a large and reliable database of tissue classifications with spectra results is required. We have developed a system that can be used to generate an efficient scanning path for robotic scanning of tissues using Raman spectroscopy. METHODS: A camera mounted to a robotic controller is used to take an image of a tissue slide. The corners of the tissue slides within the sample image are identified, and the size of the slide is calculated. The image is cropped to fit the size of the slide and the image is manipulated to identify the tissue contour. A grid set to fit around the size of the tissue is calculated and a grid scanning pattern is generated. A masked image of the tissue contour is used to create a scanning pattern containing only the tissue. The tissue scanning pattern points are transformed to the robot controller coordinate system and used for robotic tissue scanning. The pattern is validated using spectroscopic scans of the tissue sample. The run time of the tissue scan pattern is compared to a region of interest scanning pattern encapsulating the tissue using the robotic controller. RESULTS: The average scanning time for the tissue scanning pattern compared to region of interest scanning reduced by 4 minutes and 58 seconds. CONCLUSION: This method reduced the number of points used for automated robotic scanning, and can be used to reduce scanning time and unusable data points to improve data collection efficiency.