Objectives: This article aims to provide a comprehensive overview of peri‐implant mucositis, covering its etiology, risk factors, clinical features, diagnosis, and available treatment modalities. Methods: A comprehensive electronic and manual search was performed on electronic databases. Studies with focus on peri‐implant mucositis were included and reviewed comprehensively. Based on the latest evidence, decisional workflows and clinical recommendations were proposed. Results: The review highlights the multifactorial etiology of peri‐implant mucositis, primarily driven by bacterial biofilm accumulation. Key risk factors identified include poor oral hygiene, smoking, uncontrolled diabetes, and local factors such as implant surface characteristics and prosthesis design. Diagnostic criteria are based on the presence of clinical signs (inflammation, redness, swelling, and bleeding on probing (BoP)) and the absence of radiographic bone changes. Nonsurgical treatments, including mechanical debridement and photodynamic therapy (PDT), have shown effectiveness in managing the condition. However, the efficacy of adjunctive therapies remains inconclusive. Regular maintenance and optimal oral hygiene are critical in preventing and managing peri‐implant mucositis. Conclusion: Peri‐implant mucositis remains a prevalent condition in implant dentistry, with nonsurgical treatment strategies showing promising outcomes in disease management. Further research is needed to establish the long‐term effectiveness of adjunctive therapies and optimize preventive strategies for maintaining peri‐implant health.
Ultrasound (US) reveals details for diagnosing soft- and hard-tissue dimensions around teeth, implants, and the edentulous ridge, not seen in 2D radiographs. Co-registering free-hand US scans with other 3D modalities presents reliability challenges. This study first aims to develop and validate a registration method to longitudinally reproduce US images of the jawbone on a simulator. In addition, it also evaluates the degree of the anatomical match in humans between US images acquired by the proposed registration method and the commonly used freehand acquisitions in comparison to cone beam computed tomography (CBCT) and intra-oral optical scan (IOS), used as references. A previously introduced ultrasound phantom was employed as a CBCT-US hybrid, suitable for training and technique development of US guides in edentulous ridges. After establishing feasibility in the phantom, the methodology was validated in a cohort of 24 human subjects (26 cases). Soft tissues were delineated on US and IOS, and hard tissues on US and CBCT. US accuracy and repeatability from both guided and freehand scans (non-guided) was assessed as the average distance between US and the references. Guided US images resembled the references more closely than freehand (non-guided) scans. Notably, delineation of soft and hard tissues was significantly more accurate when employing guides. In the phantom, guided scans exhibited an absolute mean deviation of 81.8 µm for gingiva and 90.4 µm for bone, whereas non-guided scans showed deviations of 150.4 µm and 177.2 µm, respectively. Similarly, in vivo, guided US outperformed non-guided US, with gingiva deviations of 125 µm and 196 µm, and bone deviations of 354 µm and 554 µm, respectively. By using a registration method, guided US scans improved repeatability and accuracy of mapping hard and soft tissue of the edentulous ridge when compared to non-guided scans. This guided US imaging method could lay the foundation for longitudinal evaluation of tissue behavior and dimensional changes with improved accuracy.
The two‐implant‐supported mandibular overdenture is considered a reliable treatment option to restore masticatory function. Digital planning has been shown to improve the precision and accuracy of the surgical procedure. The outcomes are indeed pertinent to the ideal three‐dimentional positioning of the implant placement. Recently, the uses of cone‐beam computed tomography (CBCT) and intraoral scan have improved greatly the workflow of digital planning; however, the sophisticated technology caused confusion among clinicians. The purpose of this case series was to exhibit the efficacy of a bone‐supported guide in applying simultaneous implant placement and bone reduction, solely based on CBCT data. The bone reduction can therefore be determined accordingly, by adding windows to the guide, allowing the clinician to decide the amount of bone reduction as well as the location for implant placement. This novel surgical guide would not only fit properly on the bone but also provide the benefits of less‐invasive surgery and the opportunity to place implants parallel. The digital workflow described not only simplifies the fabrication process but also yields predictable surgical outcomes.
Trauma in the face region has a very varied etiology and can be associated with several important structures. Isolated fractures in the orbit region correspond to about 4 to 16% of all facial fractures and this incidence increases to 30 to 55% if we take into account fractures that expand to extraorbital regions. The present clinical report aims to describe the case of a male patient, 21-years-old, victim of a motorcycle accident with facial trauma and traumatic brain injury due to frontal collision. Clinical and imaging examinations showed multiple fractures in the face with herniation of brain mass to the orbital region and consequent extrusion of the eyeball. Surgical procedures were performed to reduce and fix fractures and multidisciplinary treatment aimed at preserving vision and brain integrity. Thus, the surgical approach and the multidisciplinary treatment led to an excellent prognosis attested by the one-year postoperative period.