Chuanming Yin

Chuanming Yin

Auto-generated profile, based on publicly available information

Chuanming Yin

School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CYChuanming Yin
Chuanming Yin
XZXiangyang Zhou
Xiangyang Zhou
WWWeiqian Wang
Weiqian Wang
XXXiaoxuan Xie
Xiaoxuan Xie
ZLZihao Lyu
Zihao Lyu
ZLZhanchao Liu
Zhanchao Liu
This paper proposes a novel approach to optimize the heating coil of atomic sensors, which can reduce the impact of heating process on performance. The atomic sensors utilize vapor cells to measure physical quantities by monitoring the precession state of alkali metal atoms, which are influenced by the magnetic field. Achieving a sufficient signal strength requires a high temperature to achieve the desired alkali metal atom density. However, the commonly used electric heating method introduces magnetic interference from the heating current. Therefore, this paper proposes an optimal design scheme in three-dimensional space to mitigate the magnetic field generated by the heating coil in the atomic sensors. By designing vertical and planar structures, the influence of the magnetic field generated during the heating process on alkali metal atoms can be significantly decreased. Firstly, the number of layers in the vertical structure is designed, and a three-layer optimal solution is proposed. Secondly, the planar structure optimization is designed by using the sparrow search algorithm to generate a minimum spatial magnetic field by the heating coil with the same length. The simulation results show that the proposed design coil reduces the magnetic field from 803.44 pT/mA to 160.72 pT/mA at a distance of 2 mm from the coil, a significant improvement over the 2 N configuration. Experimental results confirm that the magnetic field generated by the three-layer vertical structure is smaller than that of other multilayer structure, and the magnetic field generated by the optimized coil is smaller than 2 N coil.

20 November 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WWWeiqian Wang
Weiqian Wang
XZXiangyang Zhou
Xiangyang Zhou
FZFengwen Zhao
Fengwen Zhao
XXXiaoxuan Xie
Xiaoxuan Xie
YLYunyang Lian
Yunyang Lian
CYChuanming Yin
Chuanming Yin
To reduce the influence of remanence and interference on magnetocardiogram (MCG) measurements, an approach to designing nonuniform field coils (NUFCs) considering ferromagnetic coupling effects is proposed. First, a magnetic field analytical model considering the coupling effects between the magnetically shielded cylinder (MSC) and coils is established based on the distribution of the magnetic vector potential combined with the image method (IM). Subsequently, using the target field method (TFM), the NUFCs are designed inversely according to the distribution of remanence and interference, by which the problem that existing uniform field coils (UFCs) are difficult to compensate for nonuniform magnetic fields is solved. Furthermore, to improve the performance of the NUFCs, the adaptive inertia weight particle swarm optimization (PSO) method is introduced for optimizing the regularization parameters. Finally, finite-element simulations and experiments are carried out to verify the proposed method. The results from the experiments demonstrate that the remanence within the measurement area is reduced from 60 to below 10 nT by designed NUFCs, while magnetic field interference is effectively suppressed from 37 to 11 pT. These results prove the effectiveness of the designed NUFCs in enhancing the magnetic field performance of MCG devices.

15 July 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WCWenpeng Chen
Wenpeng Chen
JLJianli Li
Jianli Li
Xuelei WangXuelei Wang
Xuelei Wang
CYChuanming Yin
Chuanming Yin
AZAo Zhang
Ao Zhang
JZJunjie Zhang
Junjie Zhang
The uniform magnetic field coils within the magnetic shielding layer find numerous applications, particularly in miniature NMRG sensors. However, the target magnetic field generated by the designed coils is inevitably distorted due to the adjacent ferromagnetic material that attracts the magnetic field. To address this issue, a novel image method based on uniqueness principle is proposed, which takes into account the coupling effect between the magnetic shielding box (MSB) and the coils. The particle swarm optimization (PSO) algorithm is employed to assist the novel image method in designing highly uniform axial magnetic field coils within a compact MSB. The validity and uniformity of the designed coils are verified by the finite element method (FEM), demonstrating the maximum relative uniformity error of magnetic flux density Bz is 2.6×10−4 compared to the original point. Moreover, two classic configurations of uniform magnetic field coils, the Helmholtz coils and the 9449 coils, are introduced to compare the uniformity with the designed coils. Finally, the designed scheme was measured both within and without MSB and the experimental results indicated that the relative uniformity error of Bz was in good agreement with the reference values. These findings further substantiate the applicability of the proposed method to miniature atomic sensors that require generating a highly uniform magnetic field within the MSB.

17 July 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
CYChuanming Yin
Chuanming Yin
XZXiangyang Zhou
Xiangyang Zhou
WWWeiqian Wang
Weiqian Wang
BLBowen Liu
Bowen Liu
ZLZihao Lyu
Zihao Lyu
XXXiaoxuan Xie
Xiaoxuan Xie
Atomic sensors used for high-sensitivity magnetic-field and inertial measurements are susceptible to thermal disturbances, which cause temperature fluctuations, optical-depth variations, and sensitivity degradation. This paper proposes a disturbance-aware temperature compensation method that integrates multi-point temperature measurements, a gray-box thermal network model, and long short-term memory network-based deep deterministic policy gradient control. By using this method, the disturbance rejection ability under time-varying thermal conditions is enhanced, helping improve sensitivity stability during disturbance recovery. To validate the effectiveness of the proposed method, experiments were conducted. Compared with the tested PID and Fuzzy PID methods, the peak temperature deviation and the peak-to-peak optical depth deviation of the proposed method are reduced by up to 44.7% and 63.0%, respectively, indicating that the influence of thermal disturbances on the measured sensor response is reduced under the tested conditions.

12 June 2026 in Optics Express
Verified
Journal Article
Closed access
CYChuanming Yin
Chuanming Yin
XZXiangyang Zhou
Xiangyang Zhou
WWWeiqian Wang
Weiqian Wang
ZLZhen Li
Zhen Li
BLBowen Liu
Bowen Liu
XXXiaoxuan Xie
Xiaoxuan Xie
This paper presents a pump-light-based in-situ temperature measurement method for nuclear magnetic resonance (NMR) vapor cells under oblique optical incidence. To miniaturize the NMR sensor, a thin vapor cell is employed, in which both the orthogonal pump and probe light are introduced obliquely through one surface of the vapor cell. A model is developed to relate pump-light absorption to Rb atomic density, thereby enabling inference of the vapor cell temperature. The model includes polarization distortion, polarization-dependent window transmission attenuation, effective optical path length, and the coupling between optical absorption and atomic polarization. Experimental results show that the proposed method achieves the lowest RMSE of 0.179 K and reduces it by at least 68.2% compared with several commonly used fitting methods, enabling accurate in-situ temperature measurement in miniaturized NMR sensors under obliquely incident pumping.