9 August 2007 in Physical Review A
We demonstrate an experiment for remote preparation of arbitrary photon polarization states. With local operations, polarization measurement, and one way classical communication, any states lying on and inside the Poincaré sphere can be remotely prepared. For arbitrary pure states, the efficiency is 100% with a communication cost of one entanglement bit and two classical bits. For mixed states, polarization insensitive measurement is introduced and the classical communication cost is one bit. Spontaneous parametric down-conversion (SPDC) is employed as an entanglement source. The remotely prepared qubits are estimated via quantum tomography process and fidelity between the experimentally prepared state and the expected state is considered to test the data. We achieve remote preparation of 13 states with fidelities all above 0.994.
23 March 2012 in Physical Review A
We have measured the absolute frequency of a clock transition at the 10 level with a single, trapped, laser-cooled Ca ion in a miniature Paul trap. In our measurement, an optical frequency comb is referenced to a hydrogen maser, which is calibrated to the SI second through the Global Positioning System (GPS). By analyzing the experimental data obtained within 32 days of a total averaging time 2 10 s, the absolute frequency of the Ca 4 –3 clock transition is measured as 411 042 129 776 393.0 (1.6) Hz with a fractional uncertainty of 3.9 10.
21 November 2011 in Physical Review A
Progress on the evaluation of systematic frequency shifts is described in the development of the optical frequency standard based on single-trapped 40Ca+ with a ``clock'' transition at 729~nm. The overall systematic uncertainty of the 4s 2S1/2-3d 2D5/2 clock resonance has been characterized to be 7.8 \ifmmode\times\else\texttimes\fi{} 10$-${}16. This uncertainty is at a level similar to the Cs fountain primary standard, while the potential stability for the 40Ca+ clock exceeds that of Cs.
1 October 2008 in Optics Communications
31 March 2017 in Physical Review A
A feedback control method for producing an equidistant ion string in a surface-electrode ion trap has been experimentally demonstrated. This method features three advantages: (i) The optimal voltage can be constrained within the specified reachable range. (ii) The height of trapped ions from the trap surface can be maintained at the same value when strings with different number of ions or with different ion spacings are to be trapped. (iii) This method is resistant to a stray electric field near the trap. By this method, the asymmetry of the ion string caused by a stray field is minimized. The robustness of trapping a variable number of ions at the same potential and the dependency of the axial frequency on the number of ions are also investigated experimentally. This work would be a practical method to create a linear ion string with a large number of ions and may find applications in large-scale quantum computing, quantum simulation, and phase transition studies utilizing homogeneous ion strings.
24 October 2016 in Science China Physics, Mechanics & Astronomy