2 May 2025 in Journal of Associated Medical Sciences
Verified
Journal Article
Closed access
PPPuengjai Punikhom
Puengjai Punikhom
WKWoranan Kirisattayakul
Woranan Kirisattayakul
TPThawatchai Prabsattroo
Thawatchai Prabsattroo
WMWaranon Munkong
Waranon Munkong
PPPanuwat Pattum
Panuwat Pattum
VPVithit Pungkun
Vithit Pungkun
Background: Endovascular treatment using coiling embolization for intracranial aneurysms is common in interventional neuroradiology (INR). However, it is associated with high radiation exposure to both patients and medical staff. The assessment and management of radiation risk have been a concern. Objective: To evaluate patient and scatter radiation doses at INR staff working position during the coiling embolization procedure in a phantom study. Materials and methods: An anthropometric phantom from head to pelvis was placed on an angiographic table. To determine the phantom’s entrance skin dose (ESD), 19 NanoDot optically stimulated luminescence dosimeters (OSLDs) were placed on the surface of the head phantom. Moreover, 6 NanoDot OSLDs were also placed on the surface of the phantom at 3 critical organs (eyes, thyroid, ovaries). To determine the scatter radiation dose at staff working position, polyvinyl chloride pipes (150 cm height) were placed at the position of all staff, including interventional radiologist (IR), radiology resident (RR), scrubbed nurse (SN), radiologic technologist (RT), circulating nurse (CN), and nurse anesthetists (AN). The InLight® OSLDs were placed on each PVC pipe at 50, 100, and 150 cm height from the floor level. Coiling embolization was simulated following the standard procedure using a bi-plane digital subtraction angiography unit with standard radiation protective equipment. The patient doses from the radiation dose structured report (RDSR) were also recorded. Results: The highest ESDs were observed in the occipital part (1,631.56±36.97 mGy). These ESD peaks were also observed within the safety limit and produced no skin reaction. The radiation dose at the left eye was observed to be the highest value among critical organs. The highest scatter radiation dose was observed at the position of IR at 100 cm level. Among CN, AN, and RT positions, the highest dose was recorded at the RT position at the level of 150 cm. The RDSR showed that most of the patient radiation dose was received from the 2-dimension angiography. Conclusion: The distribution of radiation dose varied across different staff positions. As the key person conducting the coiling embolization procedure, the IR position received the highest radiation dose. Thus, close monitoring and development of additional radiation protection methods for this position are essential. Although the radiation dose at the back of the head was elevated, it remained within safety limits. Nevertheless, the monitoring of potential radiation effects should not be neglected.

1 January 2025 in Nuclear Technology and Radiation Protection
Verified
Journal Article
Open access
PDF file
PMPakjira Morhrasi
Pakjira Morhrasi
CJChayanit Jumpee
Chayanit Jumpee
VPVithit Pungkun
Vithit Pungkun
TDTanapol Dachiviriyakij
Tanapol Dachiviriyakij
PPPhiphat Phruksarojanakun
Phiphat Phruksarojanakun
KCKrisanat Chuamsaamarkkee
Krisanat Chuamsaamarkkee
The aim of this work was to estimate the eye lens dose equivalent at a depth of 3 mm and to evaluate the effectiveness of shielding for radiation workers in nuclear medicine using Monte Carlo simulation with the Monte Carlo N-Particle transport code, version 5. Published air kerma rate constants were used to validate the simulation code for commonly used radionuclides in nuclear medicine, including $ ^{18}\mathrm{F} $, $ ^{99m}\mathrm{Tc} $, and $ ^{131}\mathrm{I} $. Eye lens dose rates with commercially available syringe shields and vial shields were simulated using the Monte Carlo N-Particle code with the Posture, Individual, and Medical Application Laboratory phantom. Shielded and unshielded eye lens dose rates based on commercially available source data were simulated for common radionuclides at various distances. The maximum number of procedures was also estimated based on the eye lens dose limit recommended by the International Commission on Radiological Protection publication 118. The simulated dose rates may be used to evaluate radiation safety considerations for workers in nuclear medicine. Appropriate shielding and eye lens monitoring are particularly recommended for positron-emitting $ ^{18}\mathrm{F} $ and high-activity $ ^{131}\mathrm{I} $ procedures.