Colonic self-expandable metallic stent (SEMS) placement enables preoperative total colonoscopy (TCS) in patients with obstructive colorectal cancer. Following SEMS placement, it is possible to assess the presence or absence of synchronous proximal colon cancers and perform preoperative endoscopic resection (ER) for neoplastic lesions proximal to the primary lesion. The objective of this study was to determine the usefulness and safety of preoperative TCS and ER after SEMS placement in patients with obstructive colorectal cancer. From April 2016 to March 2022, we enrolled 100 patients with obstructive colorectal cancer who underwent SEMS placement, including 86 patients who underwent preoperative TCS after SEMS placement. Complications associated with preoperative TCS and ER after SEMS placement and the characteristics of the neoplastic lesions were assessed. The success rate of SEMS placement as bridge-to-surgery was 98.0%; six patients had associated complications. Preoperative TCS was performed 8 (range: 1–30) days after SEMS placement. Four patients had synchronous advanced cancers. Nine non-advanced synchronous cancers, 116 adenomas, and 18 sessile-serrated lesions were treated by preoperative TCS and ER after SEMS placement. No procedure-related complications, namely stent migration, bleeding, and perforation were observed. Forty-five patients underwent follow-up TCS 1 year after surgery. Only one patient with submucosal invasive cancer required a second surgery. Preoperative TCS and ER after SEMS placement was performed with no complications. This approach allows preoperative evaluation of the entire colon and the treatment of precancerous lesions. (240 words)
A 43-year-old man with rheumatic arthritis was admitted to our hospital for symptoms of cough, left chest pain, and left elbow pain, and further examination revealed an elevated level of C-reactive protein. On day 2 after admission, he underwent esophagogastroduodenoscopy. On the morning of day 7, he developed a high fever of 39.7°C, several hours after bronchoscopy. On day 13, he underwent colonoscopy. Five minutes after the colonoscopy, he developed a high fever of 39.9°C, accompanied by stridor, indicating a decrease in arterial oxygen saturation level. An intradermal test for peracetic acid which was used for cleaning flexible endoscopy was positive. We suspect that he suffered from an allergic reaction to peracetic acid following the flexible endoscopy. This is the first case reported on suspicious allergic reaction to peracetic acid following a flexible endoscopy procedure.
Background/Aims: Patients with acute cholecystitis (AC) after metallic stent (MS) placement for malignant biliary obstruction (MBO) have a high surgical risk. We performed percutaneous transhepatic gallbladder aspiration (PTGBA) as the first treatment for AC. We aimed to identify the risk factors for AC after MS placement and the poor response factors of PTGBA.Methods: We enrolled 401 patients who underwent MS placement for MBO between April 2011 and March 2020. The incidence of AC was 10.7%. Of these 43 patients, 37 underwent PTGBA as the first treatment. The patients’ responses to PTGBA were divided into good and poor response groups.Results: There were 20 patients in good response group and 17 patients in poor response group. Risk factors for cholecystitis after MS placement included cystic duct obstruction (p<0.001) and covered MS (p<0.001). Cystic duct obstruction (p=0.003) and uncovered MS (p=0.011) demonstrated significantly poor responses to PTGBA. Cystic duct obstruction is a risk factor for cholecystitis and poor response factor for PTGBA, whereas covered MS is a risk factor for cholecystitis and an uncovered MS is a poor response factor of PTGBA for cholecystitis.Conclusions: The onset and poor response factors of AC after MS placement were different between covered and uncovered MS. PTGBA can be a viable option for AC after MS placement, especially in patients with covered MS.
Although a large‐caliber endoscope (LCE) is indispensable for through‐the‐scope placement of a self‐expandable metallic stent (SEMS) in patients with malignant colonic obstruction (MCO), inaccessibility of the target obstructing lesion (TOL) by the endoscope is a significant cause of unsuccessful procedures. We herein present a novel salvage procedure when the TOL is not directly accessible by an LCE in conditions such as coexisting peritoneal carcinomatosis involving the colon. The salvage procedure, termed over‐the‐catheter endoscope replacement (OCER), starts with an ultraslim endoscope suitable for deep insertion beyond a tortuous colon for traversing a guidewire through the TOL. The ultraslim endoscope is then withdrawn and replaced by an LCE through the following steps. An endoscopic retrograde cholangiopancreatography catheter is preloaded in the LCE, the catheter alone is passed over the guidewire already traversed through the TOL, and the LCE is navigated over the catheter as far as possible toward the TOL to deliver the SEMS delivery system in a standard through‐the‐scope manner or further in an over‐the‐wire manner even if LCE insertion is incomplete. Among the 165 patients with MCO who underwent stenting during our study period, OCER led to successful procedures in all nine patients whose TOLs were initially inaccessible because of colon‐involving peritoneal carcinomatosis. By utilizing the functions of distinctive endoscopes in a unique and complementary way, OCER can be a practical salvage option for challenging cases of MCO that are highly prone to unsuccessful palliation by conventional SEMS placement.
14 January 2021 in Scandinavian Journal of Gastroenterology
Cold forceps polypectomy (CFP) is an effective treatment for diminutive colorectal polyps. However, polyps occasionally recur, and there is no consensus on their long-term clinical management. Ther...