Tayfun Bilgin

Tayfun Bilgin

Auto-generated profile, based on publicly available information

Tayfun Bilgin

Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Istanbul, Turkey

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2008 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
Hakan BilhanHakan Bilhan
Hakan Bilhan
TSTonguç Sulun
Tonguç Sulun
GGGonca Erkose Genc
Gonca Erkose Genc
HKHanefi Kurt
Hanefi Kurt
ZEZayre Erturan
Zayre Erturan
TBTayfun Bilgin
Tayfun Bilgin

19 September 2014 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
PTPinar Turk
Pinar Turk
OGOnur Geckili
Onur Geckili
YTYasin Turk
Yasin Turk
VGVolkan Gunay
Volkan Gunay
TBTayfun Bilgin
Tayfun Bilgin
Pinar Eren T?rk, PhD, DDS/Onur Geckili, PhD, DDS/Yasin T?rk, PhD, DDS/Volkan G?nay, PhD/Tayfun Bilgin, PhD, DDS: Purpose: To compare the retentive properties of ball and locator attachments during 5,000 insertion-separation cycles, corresponding to approximately 4.5 years of clinical use. Materials and Methods: Four dental implants (diameter, 3.8 mm; length, 12 mm) were inserted into the prepared beds of two polyethylene blocks. Twenty acrylic prosthetic components were fabricated and connected to the ball and locator abutments. Tensile force was applied to the prosthetic components until the attachments were separated from the abutments. All samples were subjected to 5,000 insertion-separation cycles. Retention forces were measured after 10, 100, 200, 300, 400, 500, 1,000, 1,500, 2,000, 3,000, 4,000, and 5,000 insertion-separation cycles. Additionally, the wear of the attachments was measured using scanning electron microscopy. Data were analyzed to determine statistical equivalence among the two different attachments using the Student t test procedure and the Mann-Whitney U test procedure (α = .05). Results: Ball attachments showed significant retention loss after 100, 200, 400, 500, 1,500, and 4,000 cycles, and the locator attachments showed significant retention loss after 100, 200, 300, 500, and 3,000 cycles as compared with the previous cycle (P < .05). Retention loss after 5,000 cycles was detected significantly more often for ball attachments than for locator attachments (P = .049). No significant difference was detected between the retention losses of the two attachment systems during the other cycles as compared with the initial retention values (P > .05). No significant difference was detected between the wear on the two attachment systems after 5,000 cycles (P > .05). Conclusion: Both attachment systems showed decreased retentive forces after 5,000 insertion-separation cycles. However, after 5,000 insertion-separation cycles, locator attachments showed better retentive properties than ball attachments.

1 December 2006 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
OGOnur Geckili
Onur Geckili
ACAltug Cilingir
Altug Cilingir
TBTayfun Bilgin
Tayfun Bilgin

1 September 2011 in Archives of Gerontology and Geriatrics
Verified
Journal Article
Closed access
OGOnur Geckili
Onur Geckili
Hakan BilhanHakan Bilhan
Hakan Bilhan
TBTayfun Bilgin
Tayfun Bilgin

1 April 2011 in Journal of Oral Implantology
Verified
Journal Article
Closed access
Hakan BilhanHakan Bilhan
Hakan Bilhan
OGOnur Geckili
Onur Geckili
TSTonguc Sulun
Tonguc Sulun
TBTayfun Bilgin
Tayfun Bilgin
The aim of this study was to evaluate the self-aligning overdenture attachment system by comparing its oral health–related quality of life (OHRQL) with a traditionally used ball attachment system. In this randomized, within-subject crossover trial, 25 edentulous subjects each received 2 mandibular implants, and were then assigned to receive either self-aligning or traditional ball attachments. After 3 months, all subjects were switched to the second attachment type. The OHRQL was evaluated for both of the treatments using the short form of the Oral Health Impact Profile (OHIP-14). A subanalysis among subjects with below-average space available for attachment placement was also performed. Wilcoxon signed-rank test was used to compare differences between groups. Scores on the OHIP-14 physical disability domain were significantly better for the self-aligning attachment system (P = .049). Among subjects with below-average attachment space, functional limitation, psychological discomfort, physical disability, psychological disability, and total OHIP-14, scores were significantly better for the self-aligning attachment system (P = .041, P = .047, P = .048, P = .026, and P = .005, respectively). The self-aligning attachment system for 2-implant–retained mandibular overdentures is equal or superior to traditional ball attachments in all domains of the OHIP-14.

24 August 2011 in Gerodontology
Verified
Journal Article
Closed access
PDF file
OGOnur Geckili
Onur Geckili
KBKivanc Bektas‐Kayhan
Kivanc Bektas‐Kayhan
PEPinar Eren
Pinar Eren
TBTayfun Bilgin
Tayfun Bilgin
MUMeral Unur
Meral Unur