Antonio Menditto

Antonio Menditto

Auto-generated profile, based on publicly available information

Antonio Menditto

Department of Food Safety and Veterinary Public Health, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Roma, Italy

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2006 in Accreditation and Quality Assurance
Verified
Journal Article
Closed access
PDF file
AMAntonio Menditto
Antonio Menditto
MPMarina Patriarca
Marina Patriarca
BMBertil Magnusson
Bertil Magnusson

15 April 2009 in Journal of Chromatography B
Verified
Journal Article
Closed access
ASAntonella Semeraro
Antonella Semeraro
IAIlaria Altieri
Ilaria Altieri
MPMarina Patriarca
Marina Patriarca
AMAntonio Menditto
Antonio Menditto

1 November 2002 in Clinical Chemistry
Verified
Journal Article
Open access
PDF file
ATAndrew Taylor
Andrew Taylor
JAJurgen Angerer
Jurgen Angerer
FCFrancoise Claeys
Francoise Claeys
JKJesper Kristiansen
Jesper Kristiansen
OMOlav Mazarrasa
Olav Mazarrasa
CWCas Weykamp
Cas Weykamp
Background: The different scoring methods used by eight European External Quality Assessment Schemes (EQASs) for occupational and environmental laboratory medicine were compared to develop suitable quality specifications as a step toward harmonization. Methods: Real results for blood lead and serum aluminum assays, reported by participants in Italian and United Kingdom EQASs, were evaluated according to individual scheme scoring criteria. The same results were then used to produce z scores using scheme-based between-laboratory SDs as the estimate of variability to determine whether simple performance-derived quality specifications produced better agreement among schemes. Results: The schemes gave conflicting assessments of participants’ performance, and participants judged to be successful by one scheme could be defined as performing inadequately by another. An approach proposed by Kenny et al. (Scand J Clin Lab Invest 1999;59:585), which uses clinical inputs to set targets for analytical imprecision, bias, and total error allowable, was then used to elaborate quality specifications. Conclusions: We suggest that the CLIA ′88 recommendations for blood lead (± 40 μg/L or ± 10% of the target concentration, whichever is the greater) could be used as a quality specification, although a revision to ± 30 μg/L or ± 10% is recommended. For serum aluminum, a suitable quality specification of ± 5 μg/L or ± 20% of the target concentration, whichever is the greater, is suggested. These specifications may be used to compare laboratory performance across schemes.