20 July 2023 in IEEE Transactions on Nuclear Science
Back drilling technique is useful for high-speed printed circuit board design. Currently, the stub length is measured by the destructive method that involves cutting the PCB and obtaining the results by optical imaging of the cut surface. X-ray computed laminography is an applicable technique for high-resolution imaging of plate-like object, which greatly contributes to stub nondestructive measurement. However, the inter-slice aliasing artifacts in the reconstructed images resulting from incomplete projection data make it difficult to positioning the trace layer and drilling tip. For better application to engineering, we propose to segment reconstructed slices (cross sections) of the PCB by self-training network and automatically locate key positions to measure stub length. Experiments on both simulated data and real data are carried out to verify the accuracy of the segmentation and measurement results for the proposed method. The proposed method can not only achieve nondestructive automatic rapid measurement, but obtain similar results to the state-of-art destructive method, which brings great value to via stub measurement in practical engineering applications.
1 July 2024 in Journal of X-Ray Science and Technology
BACKGROUND: The rapid development of industrialization in printed circuit board (PCB) warrants more complexity and integrity, which entails an essential procedure of PCB inspection. X-ray computed laminography (CL) enables inspection of arbitrary regions for large-sized flat objects with high resolution. PCB inspection based on CL imaging is worthy of exploration. OBJECTIVE: This work aims to extract PCB circuit layer information based on CL imaging through image segmentation technique. METHODS: In this work, an effective and applicable segmentation model for PCB CL images is established for the first time. The model comprises two components, with one integrating edge diffusion and l 0 smoothing to filter CL images with aliasing artifacts, and the other being the fuzzy energy-based active contour model driven by local pre-fitting energy to segment the filtered images. RESULT: The proposed model is able to suppress aliasing artifacts in the PCB CL images and has good performance on images of different circuit layers. CONCLUSIONS: Results of the simulation experiment reveal that the method is capable of accurate segmentation under ideal scanning condition. Testing of different PCBs and comparison of different segmentation methods authenticate the applicability and superiority of the model.
9 February 2021 in IEEE Access
Computed laminography (CL) is a nondestructive testing technique for planar objects. It has been applied in applications like printed circuit board inspection and paleontological fossils research. However, the CL system calibration is a challenging task for complex mechanical structure and many degrees of freedom. To evaluated the influence of geometric errors, a new-type microscopic CL (micro-CL) with different kinds of geometric errors was simulated. The results can guide the installation and calibration of a micro-CL scanner.
28 October 2025 in Physics in Medicine & Biology
Metal implants and other high-density objects cause significant artifacts in computed tomography (CT) images, hindering clinical diagnosis. Traditional metal artifact reduction methods often leave residual artifacts due to sinogram edges discontinuities. Supervised deep learning approaches struggle due to reliance on paired data, while unsupervised methods often lack multi-domain information. In this paper, we propose TDMAR-Net, a diffusion model-based three-domain neural network that leverages priors from projection, image, and Fourier domains for removing metal artifact and enhancing CT image quality. To enhance the model’s learning capability and gradient optimization while preventing reliance on a single data structure, we employ a two-stage training strategy that combines large-scale pretraining with masked data fine-tuning, improving both accuracy and adaptability in metal artifact removal. The specific process is to adjust the weight of the high frequency and low frequency components of the input image through the high-pass filter module in the Fourier domain, and process the image into blocks to extract the diffusion prior information. The prior information is then introduced iteratively into the sinogram and image domains to fill in the metal-induced artifacts. Our method overcomes the challenges of information sharing and complementarity across different domains, ensuring that each domain contributes effectively, thereby enhancing the precision and robustness of metal artifact elimination. Experiments show that our approach superior to existing unsupervised methods, which we have validated on both synthetic and clinical datasets.
12 December 2025 in IEEE Journal of Biomedical and Health Informatics
Sparse-view sampling in dual-energy computed tomography (DECT) significantly reduces radiation dose and increases imaging speed, yet is highly prone to artifacts. Although diffusion models have demonstrated potential in effectively handling incomplete data, most existing methods in this field focus on the image domain and lack global constraints, which consequently leads to insufficient reconstruction quality. In this study, we propose a dual-domain virtual-mask informed diffusion model for sparse-view reconstruction by leveraging the high inter-channel correlation in DECT. Specifically, the study designs a virtual mask and applies it to the high-energy and low-energy data to perform perturbation operations, thus constructing high-dimensional tensors that serve as the prior information of the diffusion model. In addition, a dual-domain collaboration strategy is adopted to integrate the information of the randomly selected high-frequency components in the wavelet domain with the information in the projection domain, for the purpose of optimizing the global structures and local details. The experimental results show that the method exhibits excellent performance on multiple datasets. Under 30-view sparse sampling conditions, VIP-DECT improves PSNR by at least 1.02 dB and enhances SSIM by 1.91%.
3 November 2026 in NDT & E International