Commutation failure is one of the common faults in the line commutated converter high voltage direct current (LCC-HVDC) transmission system, which will lead to a transient voltage disturbance with the characteristic of "decrease first and then increase" at the feed end. Such a transient voltage may cause severe dynamic responses on the wind generator adjacent to the converter station, resulting in the tripping of large-scale wind turbines and even cascading failure. By analyzing the principle of the transient voltage, this paper investigates the response mechanism of doubly-fed induction generator (DFIG), involving the variation of electrical parameters and fault ride through (FRT) ability. Further verifications through simulations and experiments prove that under the disturbance of commutation failure, DFIG may suffer greater transient shocks compared to a single sag or swell disturbance event. Finally, some suggestions are put forward to mitigate the transient voltage and improve the transient response of DFIG.
22 April 2022 in IEEE Transactions on Power Delivery
Commutation failures (CFs) including repetitive CFs (RCFs) are frequently occurring faults in line commutated converter based high voltage direct current (LCC-HVDC) systems. Consequently, sending end system will suffer transient voltage disturbances (TVD) with a characteristic of “first reduce then rise and may repeat”. Due to the complex interaction process of TVD, the electromagnetic process behind this phenomenon cannot be easily explained, which imposes great challenges on the development of mitigation strategies. Given this, this paper provides a deep insight into the mechanism and the impact factors of the TVD caused by CFs and RCFs. The numerical relationship between the transmitting power and the TVD is derived. Research results revealed that the transient process after fault can be segmented into five stages. In each stage, the control interactions among HVDC controllers and power interactions at the PCC are analyzed. Besides, we discussed the TVD under RCFs in detail. Several indices are further proposed to facilitate the characterization of the TVD, and main control loops of HVDC that have impacts on the characteristics of TVD are thereby studied. Finally, the mathematical relationship between wind farm power and the TVD is derived to quantify the impact of wind farms on the TVD.
19 January 2024 in IEEE Transactions on Power Delivery
This letter presents a new phenomenon that the integration of voltage source converter based high voltage direct current (VSC-HVDC) can increase the risk of commutation failure (CF) of line-commutated converter based HVDC (LCC-HVDC) caused by sending end AC faults, and reveals the underlying mechanism. It is found that VSC-HVDC accelerates the recovery of the active power of LCC-HVDC after fault clearance in a hybrid multi-infeed HVDC. This leads to a phase shift of the commutation voltage and high DC current in the LCC inverter, which is the inherent reason for the increased risk of CF under severe faults. And the DC impulse current is the direct reason for the increased risk of CF under moderate faults.
31 December 2020 in IEEE Transactions on Power Delivery
The increased penetration of wind power has made its low voltage ride through (LVRT) capability more crucial than ever. Currently, the LVRT performance of wind generators is verified using experimental voltage sags with different magnitudes and durations. The actual fault, however, also causes the phase angle jump (PAJ) of the grid voltage. In this paper, the impact of PAJ on the LVRT capability of doubly fed inductor generator (DFIG) under three-phase fault is analyzed. To achieve this, detailed analytical calculations and experimental verifications are conducted. The results demonstrate that the PAJ imposes more challenges on the LVRT by intensifying the rotor overcurrent through the natural stator flux. As a result, DFIGs that have passed the existing LVRT test may still fail to comply with the grid code requirements in practice. To tackle this issue, an improved test procedure is recommended. The new procedure considers the impedance angle of the target system as an additional test condition, thus can reveal the LVRT performance of DFIG under the potential PAJ.
21 June 2021 in IEEE Transactions on Applied Superconductivity
To improve the low voltage ride through (LVRT) capability of the doubly fed induction generator (DFIG), a series-connected current source converter (CSC) based superconducting magnetic energy storage (SMES) device is proposed. Based on the controllable current source characteristic of the SMES and the electromagnetic principle of the transformer, the device will behave as a dynamic impedance to suppress the overcurrent during the voltage sag period. Simulation results based on MATLAB further verify its good current limiting performance.
1 January 2020 in CSEE Journal of Power and Energy Systems