Yue Yin

Yue Yin

Auto-generated profile, based on publicly available information

Yue Yin


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in Physics of Fluids
Verified
Journal Article
Open access
PDF file
SPShidong Peng
Shidong Peng
JLJing Li
Jing Li
YYYue Yin
Yue Yin
WJWen Jian
Wen Jian
SFSi Fu
Si Fu
JLJiaxin Lu
Jiaxin Lu
The environmentally friendly insulating gas CF3I is a promising replacement for SF6 due to its excellent insulation and arc extinguishing performance. In the arc chamber of high-voltage circuit breakers filled with CF3I/CO2, the near-electrode sheath dominates the current transfer process between contact and arc column during arc formation, which has a significant effect on the transition from glow to arc discharge. The 30%CF3I/70%CO2 was taken as the research object in this research, and a more perfect fluid model was established considering the influence of diffusion current. The arc formation process between the contacts at the preliminary stage of circuit breaker interruption was conducted. The results show that the arc formation process can be divided into three stages: glow discharge, abnormal glow discharge, and arc discharge. As the arc formation process proceeds, the thickness of the near-cathode sheath decreases gradually. When the arc reaches stability with the current density 8×106–1.6×107A·m−2, the thickness of the near-cathode sheath is 7 μm, the steep voltage fall near the cathode sheath is generated within 7 μm away from the cathode surface, and this voltage fall almost does not change with the current density. CF3I− is the dominant negative ion between the contacts, which indicates that CF3I has excellent electron adsorption performance and is beneficial to arc deionization. The computational results of this work were compared with the existing experimental ones, which shows that the model used in this work is accurate enough. Finally, suggestions for model optimization and future work are given.

1 January 2025 in Physics of Plasmas
Verified
Journal Article
Open access
JLJing Li
Jing Li
YYYue Yin
Yue Yin
SPShidong Peng
Shidong Peng
SLShuxin Liu
Shuxin Liu
YFYue Fu
Yue Fu
LYLongbin Yu
Longbin Yu
Self-excited DC air circuit breaker (SE-DCCB) is widely used in urban rail transit and ship propulsion due to its excellent stability and reliability. However, the arc re-strike and small current breaking failure sometimes occur in SE-DCCB. An experimental platform of self-excited breaking was built in this work, based on which the arc root evolution during small current breaking in SE-DCCB was recorded by a high-speed camera. The magneto-hydro-dynamic model was coupled with the time-varying and non-uniformly distributed magnetic field model to investigate small current breaking in SE-DCCB, and the temperature, current density, and magnetic force of the arc were analyzed. The results show that the insufficient magnetic force of the self-excited coil and the arc root stagnation caused by the airflow vortices are the main reasons for arc re-strike, which results in the small current breaking failure in SE-DCCB. Increasing the coil turns can only reduce the arc duration; however, arc root stagnation remained unresolved. Based on the simulation results, the magnetic field in the arc chamber was reconstructed. The self-excited coil and permanent magnet was implemented to strengthen the magnetic force acting on the arc root during the last stage of small current breaking in the SE-DCCB. This approach mitigated arc root stagnation and reduced the risk of arc re-strike. This work presents reasons and influencing factors of small current breaking failure in SE-DCCB. By reconstructing the magnetic field, the small current breaking capability of SE-DCCB has been enhanced, and this work offers guidance for the optimal design of such devices.