11 November 2010 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JSJürgen Schurr
Jürgen Schurr
HMHarald Moser
Harald Moser
KPKlaus Pierz
Klaus Pierz
GRGünther Ramm
Günther Ramm
BKBryan P. Kibble
Bryan P. Kibble
This paper reports on the thermal Johnson-Nyquist noise of the quantum Hall and longitudinal resistances, which were measured both without an applied current and with an externally applied alternating or direct current. The results verify expected behavior and give interesting insights into the quantum Hall effect. They also demonstrate that ac measuring techniques commonly used in impedance metrology can take noise as a signal, reliably measuring tiny effects with a resolution of 10 pV.

1 March 2009 in MAPAN
Verified
Journal Article
Closed access
PDF file
EMEnrico Mohns
Enrico Mohns
GRGünther Ramm
Günther Ramm
WIW. G. Kürten Ihlenfeld
W. G. Kürten Ihlenfeld
LPLuis Palafox
Luis Palafox
HMHarald Moser
Harald Moser

17 April 2015 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MBMarc Florian Beug
Marc Florian Beug
HMHarald Moser
Harald Moser
This paper describes the development of a compact n/8 inductive voltage divider (IVD) for the use in the frequency range between 1 and 100 kHz and voltages up to 5 V. The development includes a number of additional inductive components for the bootstrap calibration setup such as a supply transformer which ensures the galvanic isolation of the calibration setup, a calibration transformer, and a detection transformer. The desired frequency and uncertainty range requires a two-stage IVD design with coaxial windings, a triaxial differential branch, and voltage controlled shields to minimize capacitive stray currents. The bootstrap calibration setup follows a special coaxial-by-design scheme, which guarantees nearly identical currents in inner and outer conductors of the coaxial connections without use of any chokes. The calibration of the IVD yielded in-phase and quadrature IVD corrections within 6 · 10 -6 and 1 · 10 -6 both with uncertainties (k = 2) below 1 · 10 -6 at 100 kHz.

1 July 2012
Verified
Conference Paper
Closed access
MBM. Florian Beug
M. Florian Beug
HMHarald Moser
Harald Moser
GRGunther Ramm
Gunther Ramm
This article presents a newly at PTB developed dynamic bridge standard for frequency dependent calibration of strain gauge and piezo-resistive bridge amplifiers. The bridge standard operates in a ratiometric mode by picking up the dc bridge supply voltage which is provided by the bridge amplifier under calibration. The sinusoidal or arbitrary calibration signal, the output voltage of the bridge standard, is generated by multiplying digital-to-analogue converters in combination with a resistive voltage divider. Additionally a reference signal is provided for phase calibration. The bridge standard provides the ability of static and dynamic strain gauge bridge amplifier amplitude and phase calibration in the frequency range from up to 10 kHz. The provided frequency range covers a wide range of industrial measurements of dynamic mechanical quantities such as dynamic force, torque, and pressure.

1 June 2004
Verified
Conference Paper
Closed access
GRGiinther Ramm
Giinther Ramm
HMHarald Moser
Harald Moser
A new method for the simultaneous determination of the dissipation factor of capacitors and of the time constant of resistors by a multi-frequency method is presented. This method is based on the measurement of impedance ratios at two or more frequencies. A bridge is set up with a programmable two-channel ac voltage source and the impedances to be compared. The impedance ratios are determined by synchronous sampling procedures and application of discrete Fourier transform. In a first experiment, a high-grade gas-filled 1-nF standard capacitor was compared with a stable 1-MOmega ac resistor at frequencies between 40 Hz and 660 Hz. The estimated standard uncertainties (k = 1) are 0.7 times 10 -6 for the dissipation factor of the capacitor and 0.6 ns for the time constant of the ac resistor

12 March 2007 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GRGnther Ramm
Gnther Ramm
HMHarald Moser
Harald Moser
RVReinhold Vollmert
Reinhold Vollmert
This paper describes the setup and calibration of inductive bridge standards which realize selected voltage ratios—in particular, ratios between 0.1 and 1.3—at frequencies of a few tens of hertz with uncertainties from $1 \cdot 10^{-8}$ to $2 \cdot 10^{-8}\ (k = 2)$. With these bridge standards, ac thermometry bridges can be calibrated with the lowest possible uncertainties either manually or using computer control.