Tunga Salthammer

Tunga Salthammer

Auto-generated profile, based on publicly available information

Tunga Salthammer

Department of Material Analysis and Indoor Chemistry Fraunhofer WKI 38108 Braunschweig Germany

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2010 in Chemical Reviews
Verified
Journal Article
Open access
TSTunga Salthammer
Tunga Salthammer
SMSibel Mentese
Sibel Mentese
RMRainer Marutzky
Rainer Marutzky

31 January 2013 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
TSTunga Salthammer
Tunga Salthammer

1 October 2018 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
ASAlexandra Schieweck
Alexandra Schieweck
EUErik Uhde
Erik Uhde
TSTunga Salthammer
Tunga Salthammer
LSLea C. Salthammer
Lea C. Salthammer
LMLidia Morawska
Lidia Morawska
Prashant KumarPrashant Kumar
Prashant Kumar

1 March 2019 in Building and Environment
Verified
Journal Article
Open access
TSTunga Salthammer
Tunga Salthammer

13 August 2018 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
TSTunga Salthammer
Tunga Salthammer
YZYinping Zhang
Yinping Zhang
Jinhan MoJinhan Mo
Jinhan Mo
Holger KochHolger Koch
Holger Koch
CWCharles J. Weschler
Charles J. Weschler

1 October 2018 in Environment International
Verified
Journal Article
Open access
Heidi SalonenHeidi Salonen
Heidi Salonen
TSTunga Salthammer
Tunga Salthammer
LMLidia Morawska
Lidia Morawska
Although it is recognized that ozone causes acute and chronic health effects and that even trace amounts of ozone are potentially deleterious to human health, information about global and local exposures to ozone in different indoor environments is limited. To synthesize the existing knowledge, this review analyzes the magnitude of and the trends in global and local exposure to ozone in schools and offices and the factors controlling the exposures. In conducting the literature review, Web of Science, SCOPUS, Google Scholar, and PubMed were searched using 38 search terms and their combinations to identify manuscripts, reports, and directives published between 1973 and 2018. The search was then extended to the reference lists of relevant articles. The calculated median concentration of ozone both in school (8.50 μg/m3) and office (9.04 μg/m3) settings was well below the WHO guideline value of 100 μg/m3 as a maximum 8 h mean concentration. However, a large range of average concentrations of ozone was reported, from 0.8-114 μg/m3 and from 0 to 96.8 μg/m3 for school and office environments, respectively, indicating situations where the WHO values are exceeded. Outdoor ozone penetrating into the indoor environment is the main source of indoor ozone, with median I/O ratios of 0.21 and 0.29 in school and office environments, respectively. The absence of major indoor ozone sources and ozone sinks, including gas-phase reactions and deposition, are the reasons for lower indoor than outdoor ozone concentrations. However, there are indoor sources of ozone that are of significance in certain indoor environments, including printers, photocopiers, and many other devices and appliances designed for indoor use (e.g., air cleaners), that release ozone either intentionally or unintentionally. Due to significantly elevated outdoor ozone concentrations during summer, summer indoor concentrations are typically elevated. In addition, the age of a building and various housing aspects (carpeting, air conditioning, window fans, and window openings) have been significantly associated with indoor ozone levels. The existing means for reducing ozone and ozone reaction products in school and office settings are as follows: 1) reduce penetration of outdoor ozone indoors by filtering ozone from the supply air; 2) limit the use of printers, photocopiers, and other devices and appliances that emit ozone indoors; 3) limit gas-phase reactions by limiting the use of materials and products (e.g. cleaning chemicals) the emissions of which react with ozone.