Z. Bouza

Z. Bouza

Auto-generated profile, based on publicly available information

Z. Bouza

Advanced Research Center for Nanolithography, Science Park 106, 1098 XG Amsterdam, The Netherlands

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2021 in Journal of Physics D: Applied Physics
Verified
Journal Article
Open access
PDF file
RSR Schupp
R Schupp
LBL Behnke
L Behnke
ZBZ Bouza
Z Bouza
ZMZ Mazzotta
Z Mazzotta
YMY Mostafa
Y Mostafa
OVO O Versolato
O O Versolato
The emission properties of tin plasmas, produced by the irradiation of preformed liquid tin targets by several-ns-long 2 µm-wavelength laser pulses, are studied in the extreme ultraviolet (EUV) regime. In a two-pulse scheme, a pre-pulse laser is first used to deform tin microdroplets into thin, extended disks before the main (2 µm) pulse creates the EUV-emitting plasma. Irradiating 30- to 300 µm-diameter targets with 2 µm laser pulses, we find that the efficiency in creating EUV light around 13.5 nm follows the fraction of laser light that overlaps with the target. Next, the effects of a change in 2 µm drive laser intensity (0.6–1.8 × 1011 W cm−2) and pulse duration (3.7–7.4 ns) are studied. It is found that the angular dependence of the emission of light within a 2% bandwidth around 13.5 nm and within the backward 2π hemisphere around the incoming laser beam is almost independent of intensity and duration of the 2 µm drive laser. With increasing target diameter, the emission in this 2% bandwidth becomes increasingly anisotropic, with a greater fraction of light being emitted into the hemisphere of the incoming laser beam. For direct comparison, a similar set of experiments is performed with a 1 µm-wavelength drive laser. Emission spectra, recorded in a 5.5–25.5 nm wavelength range, show significant self-absorption of light around 13.5 nm in the 1 µm case, while in the 2 µm case only an opacity-related broadening of the spectral feature at 13.5 nm is observed. This work demonstrates the enhanced capabilities and performance of 2 µm-driven plasmas produced from disk targets when compared to 1 µm-driven plasmas, providing strong motivation for the use of 2 µm lasers as drive lasers in future high-power sources of EUV light.

31 March 2021 in Physical Review Research
Verified
Journal Article
Open access
PDF file
RSR. Schupp
R. Schupp
LBL. Behnke
L. Behnke
John SheilJohn Sheil
John Sheil
ZBZ. Bouza
Z. Bouza
MBM. Bayraktar
M. Bayraktar
OVO. O. Versolato
O. O. Versolato
Experimental spectroscopic studies are presented, in a 5.5–25.5 nm extreme-ultraviolet (EUV) wavelength range, of the light emitted from plasma produced by the irradiation of tin microdroplets by 5-ns-pulsed, 2−μm-wavelength laser light. Emission spectra are compared to those obtained from plasma driven by 1−μm-wavelength laser light over a range of laser intensities spanning approximately (0.3–5)×1011W/cm2, under otherwise identical conditions. Over this range of drive laser intensities, we find that similar spectra and underlying plasma charge state distributions are obtained when keeping the ratio of 1- to 2−μm laser intensities fixed at a value of 2.1(6), which is in good agreement with ralef-2d radiation-hydrodynamic simulations. Our experimental findings, supported by the simulations, indicate an approximately inversely proportional scaling ∼λ−1 of the relevant plasma electron density, and of the aforementioned required drive laser intensities, with drive laser wavelength λ. This scaling also extends to the optical depth that is captured in the observed changes in spectra over a range of droplet diameters spanning 16–51 μm at a constant laser intensity that maximizes the emission in a 2% bandwidth around 13.5nm relative to the total spectral energy, the bandwidth relevant for EUV lithography. The significant improvement of the spectral performance of the 2−μm- versus 1−μm driven plasma provides strong motivation for the development of high-power, high-energy near-infrared lasers to enable the development of more efficient and powerful sources of EUV light.

12 August 2020 in Journal of Physics B: Atomic, Molecular and Optical Physics
Verified
Journal Article
Open access
ZBZ Bouza
Z Bouza
JSJ Scheers
J Scheers
ARA Ryabtsev
A Ryabtsev
RSR Schupp
R Schupp
LBL Behnke
L Behnke
OVO O Versolato
O O Versolato
Emission spectra from multiply-charged Sn5+–Sn10+ ions are recorded from an electron beam ion trap (EBIT) and from laser-produced plasma (LPP) in the extreme ultraviolet range relevant for nanolithographic applications. Features in the wavelength regime between 12.6 and 20.8 nm are studied. Using the Cowan code, emission line features of the charge-state-resolved Sn ion spectra obtained from the EBIT are identified. Emission features from tin LPP either from a liquid micro-droplet or planar solid target are subsequently identified and assigned to specific charge states using the EBIT data. For the planar solid tin target, the 4d–5p transitions of Sn8+–Sn10+ ions are shown to dominate the long-wavelength part of the measured spectrum and transitions of type 4d–4f + 4p–4d are visible in absorption. For the droplet target case, a clear increase in the charge state distribution with increasing laser intensity is observed. This qualitatively demonstrates the potential of using long-wavelength out-of-band emission features to probe the charge states contributing to the strong unresolved transition array at 13.5 nm relevant for nanolithography.

1 December 2021 in AIP Advances
Verified
Journal Article
Open access
PDF file
ZBZ. Bouza
Z. Bouza
JBJ. Byers
J. Byers
JSJ. Scheers
J. Scheers
RSR. Schupp
R. Schupp
YMY. Mostafa
Y. Mostafa
OVO. O. Versolato
O. O. Versolato
We present a calibrated spectrum in the 5.5–265.5 nm range from a microdroplet-tin Nd:YAG-laser-produced plasma under conditions relevant for the production of extreme ultraviolet (EUV) light at 13.5 nm for nanolithography. The plasma emission spectrum obtained using a custom-built transmission grating spectrometer results from a careful calibration of a series of filters enabling measurements free of any higher diffraction orders. Specifically, Zr, Si, and Al thin-foil filters and bulk LiF, MgF2, and UV fused silica filters are employed. A further filter using four SiC mirrors is used to record the otherwise inaccessible 40–100 nm range. The resulting corrected and concatenated spectra are shown to accurately match in their respective overlap regions. The possibility to measure spectra over this broad range enables the optimization of current and future sources of EUV light for nanolithography by providing the diagnostics required for minimizing the emission of unwanted wavelength bands.

27 January 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
YMY. Mostafa
Y. Mostafa
LBL. Behnke
L. Behnke
DED. J. Engels
D. J. Engels
ZBZ. Bouza
Z. Bouza
John SheilJohn Sheil
John Sheil
OVO. O. Versolato
O. O. Versolato