1 August 2016 in Nuclear Medicine and Biology
31 May 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Positrons are widely used in molecular imaging through the Positron Emission Tomography (PET) imaging technique. However PET only reconstruct the distribution of the positron emitting radioisotopes, and because the β+ isotopes are linked to a vector molecule, the distribution of β+ isotopes is correlated to the distribution of a given biological function. Positron-electron annihilation can transit through a meta-stable called positronium, which can exist in two spin states: the single state -parapositronium -and the triplet state -orthopositronium. The orthopositronium lifetime (τoPs), formation probabilities and decay modes are sensitive to the physical and chemical state of the neighboring medium and could therefore provide information on the tissues themselves during a PET acquisition. However, traditional PET only relies on the detection of the two annihilation photons, therefore the lifetime and annihilation higher multiplicity annihilations are not accessible to such PET paradigm. This review will present some of the use cases of positronium as a specific signature for event selection in astrophysics and particle physics, and as a probe for the microscopic state of materials and tissues. These usages of positronium highlight the interest for positronium for diagnostic in medical science, the projects for using positronium in upcoming PET tomographs are then presented.
1 September 2015 in NeuroImage
1 March 2016 in Physics in Medicine & Biology
Nowadays, Single Photon imaging has become an essential part of molecular imaging and nuclear medicine. Whether to establish a diagnosis or in the therapeutic monitoring, this modality presents performance that continues to improve. For over 50 years, several collimators have been proposed. Mainly governed by collimation parameters, the resolution-sensitivity trade-off is the factor determining the collimator the most suitable for an intended study. One alternative to the common approaches is the rotating slat collimator (RSC). In the present study, we are aiming at developing a preclinical system equipped with a RSC dedicated to mice and rats imaging, which requires both high sensitivity and spatial resolution. We investigated the resolution-sensitivity trade-offs obtained by varying different collimation parameters: (i) the slats height (H), and (ii) the gap between two consecutive slats (g), considering different intrinsic spatial resolutions. One system matrix was generated for each set of collimation parameters (H,g). Spatial resolutions, Signal-to-Noise Ratio (SNR) and sensitivity obtained for all the set of collimation parameters (H,g) were measured in the 2D projections reconstructed with ML-EM. According to our results, 20 mm high slats and a 1 mm gap were chosen as a good RSC candidate for a preclinical detection module. This collimator will ensure a sensitivity greater than 0.2% and a system spatial resolution below 1 mm, considering an intrinsic spatial resolution below 0.8 mm.