Frédéric Boisson

Frédéric Boisson

Auto-generated profile, based on publicly available information

Frédéric Boisson

Institut Pluridisciplinaire Hubert Curien, Universit de Strasbourg, Strasbourg, France

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2016 in Nuclear Medicine and Biology
Verified
Journal Article
Closed access
PMPatrice Marchand
Patrice Marchand
AOAli Ouadi
Ali Ouadi
MPMichel Pellicioli
Michel Pellicioli
JSJacky Schuler
Jacky Schuler
PLPatrice Laquerriere
Patrice Laquerriere
DBDavid Brasse
David Brasse

31 May 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
AHA. Hourlier
A. Hourlier
FBF. Boisson
F. Boisson
DBDavid Brasse
David Brasse
Positrons are widely used in molecular imaging through the Positron Emission Tomography (PET) imaging technique. However PET only reconstruct the distribution of the positron emitting radioisotopes, and because the β+ isotopes are linked to a vector molecule, the distribution of β+ isotopes is correlated to the distribution of a given biological function. Positron-electron annihilation can transit through a meta-stable called positronium, which can exist in two spin states: the single state -parapositronium -and the triplet state -orthopositronium. The orthopositronium lifetime (τoPs), formation probabilities and decay modes are sensitive to the physical and chemical state of the neighboring medium and could therefore provide information on the tissues themselves during a PET acquisition. However, traditional PET only relies on the detection of the two annihilation photons, therefore the lifetime and annihilation higher multiplicity annihilations are not accessible to such PET paradigm. This review will present some of the use cases of positronium as a specific signature for event selection in astrophysics and particle physics, and as a probe for the microscopic state of materials and tissues. These usages of positronium highlight the interest for positronium for diagnostic in medical science, the projects for using positronium in upcoming PET tomographs are then presented.

1 September 2015 in NeuroImage
Verified
Journal Article
Closed access
ARAnthonin Reilhac
Anthonin Reilhac
ACArnaud Charil
Arnaud Charil
CWCatriona Wimberley
Catriona Wimberley
GAGeorgios Angelis
Georgios Angelis
HHHasar Hamze
Hasar Hamze
MGMarie-Claude Gregoire
Marie-Claude Gregoire

29 July 2022 in Molecules
Verified
Journal Article
Open access
PDF file
ALAdrien Latgé
Adrien Latgé
FBFrédéric Boisson
Frédéric Boisson
AOAli Ouadi
Ali Ouadi
GAGerlinde Averous
Gerlinde Averous
LTlionel thomas
lionel thomas
DBDavid Brasse
David Brasse
64CuCl2 is an economic radiotracer for oncologic PET investigations. In the present study, we characterized the uptake of 64CuCl2 in vivo by µPET/CT in an allograft 4T1-related mouse model (BALB/c) of advanced breast cancer. 18F-FDG was used as a comparator. Twenty-two animals were imaged 7–9 days following 4T1-cell implantation inside mammary glands. Dynamic 64CuCl2 µPET/CT acquisition or iterative static images up to 8 h p.i. were performed. Animal biodistribution and tumor uptake were first evaluated in vivo by µPET analysis and then assessed on tissue specimens. Concerning 18F-FDG µPET, a static acquisition was performed at 15 min and 60 min p.i. Tumor 64CuCl2 accumulation increased from 5 min to 4 h p.i., reaching a maximum value of 5.0 ± 0.20 %ID/g. Liver, brain, and muscle 64CuCl2 accumulation was stable over time. The tumor-to-muscle ratio remained stable from 1 to 8 h p.i., ranging from 3.0 to 3.7. Ex vivo data were consistent with in vivo estimations. The 18F-FDG tumor accumulation was 8.82 ± 1.03 %ID/g, and the tumor-to-muscle ratio was 4.54 ± 1.11. 64CuCl2 PET/CT provides good characterization of the 4T1-related breast cancer model and allows for exploration of non-glycolytic cellular pathways potentially of interest for theragnostic strategies.

5 July 2024 in Molecules
Verified
Journal Article
Open access
PDF file
TMTimothé Maujean
Timothé Maujean
SRSridevi Ramanoudjame
Sridevi Ramanoudjame
SRStéphanie Riché
Stéphanie Riché
CGClothilde Le Guen
Clothilde Le Guen
FBFrédéric Boisson
Frédéric Boisson
PMPatrice Marchand
Patrice Marchand
Radiolabeled peptides are valuable tools for diagnosis or therapies; they are often radiofluorinated using an indirect approach based on an F-18 prosthetic group. Herein, we are reporting our results on the F-18 radiolabeling of three peptides using two different methods based on click reactions. The first one used the well-known CuAAC reaction, and the second one is based on our recently reported hetero-Diels–Alder (HDA) using a dithioesters (thia-Diels–Alder) reaction. Both methods have been automated, and the 18F-peptides were obtained in similar yields and synthesis time (37–39% decay corrected yields by both methods in 120–140 min). However, to obtain similar yields, the CuAAC needs a large amount of copper along with many additives, while the HDA is a catalyst and metal-free reaction necessitating only an appropriate ratio of water/ethanol. The HDA can therefore be considered as a minimalist method offering easy access to fluorine-18 labeled peptides and making it a valuable additional tool for the indirect and site-specific labeling of peptides or biomolecules.

1 March 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
FBF Boisson
F Boisson
VBV Bekaert
V Bekaert
DBD Brasse
D Brasse
Nowadays, Single Photon imaging has become an essential part of molecular imaging and nuclear medicine. Whether to establish a diagnosis or in the therapeutic monitoring, this modality presents performance that continues to improve. For over 50 years, several collimators have been proposed. Mainly governed by collimation parameters, the resolution-sensitivity trade-off is the factor determining the collimator the most suitable for an intended study. One alternative to the common approaches is the rotating slat collimator (RSC). In the present study, we are aiming at developing a preclinical system equipped with a RSC dedicated to mice and rats imaging, which requires both high sensitivity and spatial resolution. We investigated the resolution-sensitivity trade-offs obtained by varying different collimation parameters: (i) the slats height (H), and (ii) the gap between two consecutive slats (g), considering different intrinsic spatial resolutions. One system matrix was generated for each set of collimation parameters (H,g). Spatial resolutions, Signal-to-Noise Ratio (SNR) and sensitivity obtained for all the set of collimation parameters (H,g) were measured in the 2D projections reconstructed with ML-EM. According to our results, 20 mm high slats and a 1 mm gap were chosen as a good RSC candidate for a preclinical detection module. This collimator will ensure a sensitivity greater than 0.2% and a system spatial resolution below 1 mm, considering an intrinsic spatial resolution below 0.8 mm.