Martin Villiger

Martin Villiger

Auto-generated profile, based on publicly available information

Martin Villiger

Laboratoire d’Optique Biomédicale, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2010 in Optics Letters
Verified
Journal Article
Closed access
PDF file
MVMartin Villiger
Martin Villiger
CPChristophe Pache
Christophe Pache
TLTheo Lasser
Theo Lasser
Dark-field illumination is known to enhance scattering contrast in optical microscopy. We combined this concept with Fourier domain optical coherence microscopy (OCM). The detection and illumination paths are decoupled, and only the scattered light originating from the sample generates the tomogram signal, whereas any specular reflection is highly suppressed. We analyze and discuss this dark-field OCM concept and present its superior imaging quality on live cell samples.

22 September 2010 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
MVMartin Villiger
Martin Villiger
TLTheo Lasser
Theo Lasser
In this work we present a model for image formation in optical coherence microscopy. In the spectral domain detection, each wavenumber has a specific coherent transfer function that samples a different part of the object’s spatial frequency spectrum. The reconstruction of the tomogram is usually accurate only in a short depth of field. Using numerical simulations based on the developed model, we identified two distinct mechanisms that influence the signal of out-of-focus sample information. Besides the lateral blurring induced through defocusing, an additional axial envelope contributing equally to the signal degradation was found.

30 May 2009 in Diabetologia
Verified
Journal Article
Closed access
PDF file
MVM. Villiger
M. Villiger
JGJ. Goulley
J. Goulley
MFM. Friedrich
M. Friedrich
AGA. Grapin-Botton
A. Grapin-Botton
PMP. Meda
P. Meda
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb

11 February 2010
Verified
Conference Paper
Closed access
TSTilman Schmoll
Tilman Schmoll
ASAmardeep S. G. Singh
Amardeep S. G. Singh
KFKarine Frily
Karine Frily
CBCedric Blatter
Cedric Blatter
MVMartin Villiger
Martin Villiger
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
We developed a high speed Doppler tomography system together with flow extraction algorithms that provide a flexible tool to assess retinal perfusion. The aim of the present study is to stimulate perfusion by flickering with light of adjustable color and to measure changes depending on light frequency and flicker location. We observed relative changes in arterial flow velocity during flicker stimulation up to 50%. We found in arteries close to the optic nerve head the highest flicker response at a frequency of 8Hz. We believe that a multimodal functional imaging concept is of high value for an accurate and early diagnosis and understanding of retinal pathologies and pathogenesis.