Functional near-infrared spectroscopy (fNIRS) is a noninvasive neuroimaging technique to monitor brain activity indirectly. It measures the intensity of near-infrared light diffusely scattered through cortical tissues to quantify changes in oxyhemoglobin concentration (HbO) and deoxyhemoglobin concentration (HbR) with respect to cortical regions.1–4 HbO and HbR time series can reflect changes in neurovascular coupling and hence, neuronal activity. fNIRS has been widely used in cognitive,5–9 motor skill studies,10–15 and brain–computer interface technique.16
Background. Google Glass has been used in a variety of medical settings with promising results. We explored the use and potential value of an asynchronous, near-real time protocol—which avoids transmission issues associated with real-time applications—for recording, uploading, and viewing of high-definition (HD) visual media in the emergency department (ED) to facilitate remote surgical consults. Study Design. First-responder physician assistants captured pertinent aspects of the physical examination and diagnostic imaging using Google Glass’ HD video or high-resolution photographs. This visual media were then securely uploaded to the study website. The surgical consultation then proceeded over the phone in the usual fashion and a clinical decision was made. The surgeon then accessed the study website to review the uploaded video. This was followed by a questionnaire regarding how the additional data impacted the consultation. Results. The management plan changed in 24% (11) of cases after surgeons viewed the video. Five of these plans involved decision making regarding operative intervention. Although surgeons were generally confident in their initial management plan, confidence scores increased further in 44% (20) of cases. In addition, we surveyed 276 ED patients on their opinions regarding concerning the practice of health care providers wearing and using recording devices in the ED. The survey results revealed that the majority of patients are amenable to the addition of wearable technology with video functionality to their care. Conclusions. This study demonstrates the potential value of a medically dedicated, hands-free, HD recording device with internet connectivity in facilitating remote surgical consultation.
Operating room (OR) safety has become a major concern in patient safety since the 1990s. Improvement of team communication and behavior is a popular target for safety programming at the institutional level. Despite these efforts, essential safety gaps remain in the OR and procedure rooms. A prime example is the use of energy-based devices in ORs and procedural areas. The lack of fundamental understanding of energy device function, design, and application contributes to avoidable injury and harm at a rate of approximately 1 to 2 per 1000 patients in the US. Hundreds of OR fires occur each year in the US, some causing severe injury and even death. Most of these fires are associated with the use of energy-based surgical devices.In response to this safety issue, the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) developed the Fundamental Use of Surgical Energy (FUSE) program. This program includes a standardized curriculum targeted to surgeons, other physicians, and allied health care professionals and a psychometrically designed and validated certification test. A successful FUSE certification documents acquisition of the basic knowledge needed to safely use energy-based devices in the OR. By design FUSE fills a void in the curriculum and competency assessment for surgeons and other procedural specialists in the use of energy-based devices in patients.