1 February 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Epoxy resin is widely used as electrical insulation material and its electrical degradation is significantly influenced by ionic conduction. However, the theoretical understanding of ionic transfer in epoxy is limited. In this study, sodium ion (Na+) and chloride ion (Cl-) mobility in epoxy resin are computed using molecular dynamics (MD) simulation, and their electric field dependence and temperature dependence are discussed. The calculated ionic mobility is consistent with the experimental results. The ionic mobility and its Arrhenius activation energy of Cl-are respectively larger and smaller than those of Na+. The MD results also suggest that the effect of free volume on ionic conduction is small. To further analyze the ion transport mechanism, the interaction energy between the ion and surrounding epoxy molecules when the ion is at a stable “trap” site and a “barrier” site for ion is calculated. The results show that the potential barrier for ion transportation in epoxy resin is smaller for Cl-than Na+, and hence Cl-ion mobility is larger than Na+. Furthermore, the effect of water in epoxy on ionic mobility is computed. The computed ionic mobility is larger for the water-containing system. This is because hydration inhibits the bonding between the ions and epoxy molecules. A comparison is also conducted between the MD computed mobility and the mobility calculated by classical ionic conduction theory. This study reveals the relationship between the microscopic interactions of the ion and surrounding molecules and the macroscopic ionic mobility in epoxy.
1 January 2008 in Doboku Gakkai Ronbunshuu D
16 June 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Dry air is promising as an alternative insulation medium for SF6 gas in high voltage equipment. Since its dielectric strength is about one-third of that of SF6 gas, one of the most effective ways to apply dry air to high voltage gas-insulated switchgears (GIS) is to further increase gas pressure. In this paper, impulse breakdown strength of dry air at high pressure under quasi-uniform electric field is measured. Furthermore, the probability distribution of breakdown voltage is predicted using Volume-Time theory in consideration of initial electron generation probability in gas gap and field electron emission from an electrode. Predicted distribution of breakdown voltage by Volume-Time theory is in line with the experimental results.
11 May 2023 in Journal of Physics D: Applied Physics
Polymer nanocomposites (PNCs) exhibit excellent electrical properties owing to charge trapping provided by nanofillers. However, the role of nanofillers in trap formation at the microscopic level is poorly understood. In this study, we propose a method to determine the charge trap depth of nanofillers in PNCs using x-ray photoelectron spectroscopy (XPS) measurements and first-principles calculations. The low-density polyethylene (PE)/TiO2 nanocomposite is selected as the measurement target as it was previously reported the charges are trapped by TiO2 loading to PE. We observe TiO2 can serve as a trap for holes, and the trap depth is determined to be 0.9 eV. Furthermore, the computed charge trap depth calculated by G 0 W 0 calculation, which reproduce the experimental band gap, is comparable to the XPS result, which strongly supports the validity of our method. In addition, owing to the quantitative evaluation of the electronic structure, it was shown that the charge trap depth of the nanofiller can be controlled by tuning the surface dipole with surface modification of the nanofiller. The approach proposed in this study to determine the charge trap depth of nanofillers provides the prospect of designing PNCs with desirable properties from the atomic or molecular level.
11 September 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Since charge injection from metals into insulating polymers leads to electrical degradation and failure of various electrical devices, it is essential to clarify the band alignment at the metal/insulating polymer interface. However, the electronic structure at the metal/insulating polymer interface has not been studied experimentally. In this contribution, band alignments at the Au/polytetrafluoroethylene (PTFE) and Au/polypropylene (PP) interfaces were determined by first principles calculations using density functional theory (DFT) and X-ray photoelectron spectroscopy (XPS) measurements. The calculated electronic properties on Au/PP interface are in agreement with the experimental results, indicating that the vacuum level shift at the interface is slight (below 0.3 eV). On the other hand, in the case of PTFE, even though the computed vacuum level shift for an ideal interface was small (-0.1 eV), the experimental results indicated that the vacuum level shift can be more than 1.7 eV. The results suggest that, in actual systems, the vacuum level shift may be caused by the impurities or defects at the interface. Our work has led us to conclude that the band alignment of the metal/polymer interface depends not only on the combination of material species but also on the way the contact is formed between them.
6 November 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Charge injection from a metal into a dielectric polymer is one of the key factors responsible for the degradation of polymers. The charge injection barrier (the band alignment) at the metal/dielectric interface is considered to be an important factor for charge injection. In this study, to understand how the band alignment is determined, the interfaces between the Au electrodes and polymers are studied at an atomic level with the combination of X-ray photoelectron spectroscopy measurements and first-principles calculations. Various polymers with different polarity and saturation, such as polyethylene (PE), polystyrene (PS), and polyimide (PI), are used for this purpose. The results indicated that the energy level shift at the Au/polymer interfaces is almost negligible. It is also suggested that, in some cases, chemisorption at the interface can increase (decrease) the electron (hole) injection barrier by more than 1 eV.