2 June 2022 in PLOS Computational Biology
Pulmonary drug delivery systems rely on inhalation of drug-laden aerosols produced from aerosol generators such as inhalers, nebulizers etc. On deposition, the drug molecules diffuse in the mucus layer and are also subjected to mucociliary advection which transports the drugs away from the initial deposition site. The availability of the drug at a particular region of the lung is, thus, determined by a balance between these two phenomena. A mathematical analysis of drug deposition and retention in the lungs is developed through a coupled mathematical model of aerosol transport in air as well as drug molecule transport in the mucus layer. The mathematical model is solved computationally to identify suitable conditions for the transport of drug-laden aerosols to the deep lungs. This study identifies the conditions conducive for delivering drugs to the deep lungs which is crucial for achieving systemic drug delivery. The effect of different parameters on drug retention is also characterized for various regions of the lungs, which is important in determining the availability of the inhaled drugs at a target location. Our analysis confirms that drug delivery efficacy remains highest for aerosols in the size range of 1-5 μm. Moreover, it is observed that amount of drugs deposited in the deep lung increases by a factor of 2 when the breathing time period is doubled, with respect to normal breathing, suggesting breath control as a means to increase the efficacy of drug delivery to the deep lung. A higher efficacy also reduces the drug load required to be inhaled to produce the same health effects and hence, can help in minimizing the side effects of a drug.
20 January 2020 in Journal of Thermal Analysis and Calorimetry
1 August 2016 in Nuclear Engineering and Design
1 December 2019 in Physics of Fluids
The present study aims to develop a fundamental understanding of the complex nature of fluid flow and particle transport dynamics in the alveolar region of the lungs. The acinus has a fine-scaled structure which allows for gas exchange in the blood. We model the transport characteristics of a single alveolar duct, which represents a single unit of the fine-scale acinar structure. A straight duct, with an expanding/contracting hemispherical bulb at one end, is used as a simplified approximation of a breathing alveolus. The diffusion of respiratory gases is considered across the boundary of the hemispherical bulb in order to account for the gas exchange. The transport equations are solved numerically using an Eulerian-Eulerian approach. The transport of aerosol particles could be demarcated into transient and time-periodic regimes, each with significantly different characteristics. While diffusion is observed to be the main cause of particle transport in the transient regime, the periodic nature of advective particle motion dominates in the time-periodic regime. Surprisingly, particle transport toward the acinus is observed even in a time-periodic breathing flow due to the nonlinear advective acceleration. A reduction in the particle size is observed to substantially aid the transport of aerosols. While gas exchange and increase in breathing frequency aid aerosol transport, the increase in the rate of aerosol transfer is observed to merely lower the aerosol concentration within the duct.
1 February 2021 in International Communications in Heat and Mass Transfer
5 August 2022 in Waves in Random and Complex Media
The scope of this work is to investigate the influence of an obstruction size and its location on the buoyancy-driven convection in a concentric annulus. The inner cylinder of an annulus is maintained at higher temperature than the outer cylinder. An obstructing adiabatic block is placed in the space between the annulus. To explore the impact of the obstruction on the thermo-fluid flow structure, the block size and its position are varied. The annular region between the cylinders is assumed to be filled with air. The governing differential equations are solved numerically via the finite volume technique-based solver. The simulations are carried out for a controlling range of Rayleigh numbers (Ra = 103–105). The effect of the block size ( = 0–0.8) and its positions ( °) on the heat transfer features are extensively examined. It is observed that the heat transfer is maximum for a particular Rayleigh number, block size, and its position. There exist a critical Rayleigh number (Racr) for the enhanced heat transfer. Depending on the block size and its position and Racr, the flow structure exhibits multi-cellular formation, which dictates the heat transfer markedly. The average heat transfer rate improves markedly up to a certain block size and convection regime, after which thermal behavior deteriorates. The local heat transfer attains a peak value near the location, where multi-cells are formed. The heat transfer enhancement parameter is approximately equal to 10% for the optimum block size. The findings of this study will be very helpful for the designing of the thermal system pertaining to efficient heat exchanging devices and other technological applications. Highlights GRAPHICAL ABSTRACT