Juhani Aakko

Juhani Aakko

Auto-generated profile, based on publicly available information

Juhani Aakko

Medaffcon Oy, Espoo, Finland

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
HKHenri Korkalainen
Henri Korkalainen
Timo LeppänenTimo Leppänen
Timo Leppänen
JAJuhani Aakko
Juhani Aakko
SNSami Nikkonen
Sami Nikkonen
SKSamu Kainulainen
Samu Kainulainen
JTJuha Toyras
Juha Toyras
The identification of sleep stages is essential in the diagnostics of sleep disorders, among which obstructive sleep apnea (OSA) is one of the most prevalent. However, manual scoring of sleep stages is time-consuming, subjective, and costly. To overcome this shortcoming, we aimed to develop an accurate deep learning approach for automatic classification of sleep stages and to study the effect of OSA severity on the classification accuracy. Overnight polysomnographic recordings from a public dataset of healthy individuals (Sleep-EDF, n = 153) and from a clinical dataset (n = 891) of patients with suspected OSA were used to develop a combined convolutional and long short-term memory neural network. On the public dataset, the model achieved sleep staging accuracy of 83.7% (κ = 0.77) with a single frontal EEG channel and 83.9% (κ = 0.78) when supplemented with EOG. For the clinical dataset, the model achieved accuracies of 82.9% (κ = 0.77) and 83.8% (κ = 0.78) with a single EEG channel and two channels (EEG+EOG), respectively. The sleep staging accuracy decreased with increasing OSA severity. The single-channel accuracy ranged from 84.5% (κ = 0.79) for individuals without OSA diagnosis to 76.5% (κ = 0.68) for patients with severe OSA. In conclusion, deep learning enables automatic sleep staging for suspected OSA patients with high accuracy and expectedly, the accuracy decreased with increasing OSA severity. Furthermore, the accuracies achieved in the public dataset were superior to previously published state-of-the-art methods. Adding an EOG channel did not significantly increase the accuracy. The automatic, single-channel-based sleep staging could enable easy, accurate, and cost-efficient integration of EEG recording into diagnostic ambulatory recordings.

24 August 2017 in Beneficial Microbes
Verified
Journal Article
Closed access
JAJ. Aakko
J. Aakko
HKH. Kumar
H. Kumar
SRS. Rautava
S. Rautava
AWA. Wise
A. Wise
CAC. Autran
C. Autran
SSS. Salminen
S. Salminen
Human milk oligosaccharides (HMOs) are structurally diverse unconjugated glycans with a composition unique to each lactating mother. While HMOs have been shown to have an impact on the development of infant gut microbiota, it is not well known if HMOs also already affect milk microbial composition. To address this question, we analysed eleven colostrum samples for HMO content by high-pressure liquid chromatography and microbiota composition by quantitative PCR. Higher total HMO concentration was associated with higher counts of Bifidobacterium spp. (ρ=0.63, P=0.036). A distinctive effect was seen when comparing different HMO groups: positive correlations were observed between sialylated HMOs and Bifidobacterium breve (ρ=0.84, P=0.001), and non-fucosylated/non-sialylated HMOs and Bifidobacterium longum group (ρ=0.65, P=0.030). In addition to associations between HMOs and bifidobacteria, positive correlations were observed between fucosylated HMOs and Akkermansia muciniphila (ρ=0.70, P=0.017), and between fucosylated/sialylated HMOs and Staphylococcus aureus (ρ=0.75, P=0.007). Our results suggest that the characterised HMOs have an effect on specific microbial groups in human milk. Both oligosaccharides and microbes provide a concise inoculum for the compositional development of the infant gut microbiota.

9 December 2020 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
HKHenri Korkalainen
Henri Korkalainen
Timo LeppänenTimo Leppänen
Timo Leppänen
BDBrett Duce
Brett Duce
SKSamu Kainulainen
Samu Kainulainen
JAJuhani Aakko
Juhani Aakko
JTJuha Toyras
Juha Toyras
Traditional sleep staging with non-overlapping 30-second epochs overlooks multiple sleep-wake transitions. We aimed to overcome this by analyzing the sleep architecture in more detail with deep learning methods and hypothesized that the traditional sleep staging underestimates the sleep fragmentation of obstructive sleep apnea (OSA) patients. To test this hypothesis, we applied deep learning-based sleep staging to identify sleep stages with the traditional approach and by using overlapping 30-second epochs with 15-, 5-, 1-, or 0.5-second epoch-to-epoch duration. A dataset of 446 patients referred for polysomnography due to OSA suspicion was used to assess differences in the sleep architecture between OSA severity groups. The amount of wakefulness increased while REM and N3 decreased in severe OSA with shorter epoch-to-epoch duration. In other OSA severity groups, the amount of wake and N1 decreased while N3 increased. With the traditional 30-second epoch-to-epoch duration, only small differences in sleep continuity were observed between the OSA severity groups. With 1-second epoch-to-epoch duration, the hazard ratio illustrating the risk of fragmented sleep was 1.14 (p = 0.39) for mild OSA, 1.59 (p <; 0.01) for moderate OSA, and 4.13 (p <; 0.01) for severe OSA. With shorter epoch-to-epoch durations, total sleep time and sleep efficiency increased in the non-OSA group and decreased in severe OSA. In conclusion, more detailed sleep analysis emphasizes the highly fragmented sleep architecture in severe OSA patients which can be underestimated with traditional sleep staging. The results highlight the need for a more detailed analysis of sleep architecture when assessing sleep disorders.

17 February 2022 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
NWNing Wang
Ning Wang
VLVladislav Lysenkov
Vladislav Lysenkov
KOKatri Orte
Katri Orte
VKVeli Kairisto
Veli Kairisto
JAJuhani Aakko
Juhani Aakko
LELaura L. Elo
Laura L. Elo
Insertions and deletions (indels) in human genomes are associated with a wide range of phenotypes, including various clinical disorders. High-throughput, next generation sequencing (NGS) technologies enable the detection of short genetic variants, such as single nucleotide variants (SNVs) and indels. However, the variant calling accuracy for indels remains considerably lower than for SNVs. Here we present a comparative study of the performance of variant calling tools for indel calling, evaluated with a wide repertoire of NGS datasets. While there is no single optimal tool to suit all circumstances, our results demonstrate that the choice of variant calling tool greatly impacts the precision and recall of indel calling. Furthermore, to reliably detect indels, it is essential to choose NGS technologies that offer a long read length and high coverage coupled with specific variant calling tools.

9 October 2022 in Clinical and Translational Allergy
Verified
Journal Article
Open access
STSanna Toppila-Salmi
Sanna Toppila-Salmi
JHJenni Hällfors
Jenni Hällfors
JAJuhani Aakko
Juhani Aakko
BMBettina Mannerstrom
Bettina Mannerstrom
KNKaisa Nieminen
Kaisa Nieminen
LLLauri Lehtimäki
Lauri Lehtimäki
Background: Chronic rhinosinusitis with nasal polyps (CRSwNP) is commonly associated with asthma. Treatment of CRSwNP includes intranasal and systemic corticosteroids, with non‐responsive patients commonly considered for endoscopic sinus surgery (ESS). This nationwide register‐based study evaluated the incidence, prevalence, and treatment burden of CRSwNP in Finland, and their association with the presence and severity of comorbid asthma.Methods: Electronic health records of patients diagnosed with CRSwNP between 1.1.2012 and 31.12.2018 in Finnish specialty and primary care were included in the study. The patients were divided into subgroups based on presence, severity, and control of asthma: no asthma, mild to moderate asthma, severe controlled asthma, and severe uncontrolled asthma. A mean cumulative count of ESS was calculated over time per subgroup.Results: The prevalence of CRSwNP increased from 602.2 to 856.7 patients per 100,000 population between years 2012 and 2019 (p < 0.001). A total of 18,563 patients (59.9% male) had incident CRSwNP between 2012 and 2019, with 27% having asthma, 6% having severe asthma, and 1.5% having severe uncontrolled asthma. In the no asthma, severe controlled asthma, and severe uncontrolled asthma subgroups, systemic corticosteroids were used by 54.1%, 94.9% and 99.3% (p < 0.001), respectively, while the ESS count 3 years post diagnosis was 0.49, 0.68 and 0.80, respectively.Conclusions: The prevalence of CRSwNP showed a significant increase in the recent decade in Finland. Comorbid asthma, and in particular severe asthma, increased the probability of receiving systemic corticosteroids and undergoing ESS. Thus, improved management of CRSwNP in patients with comorbid asthma is urgently needed.

29 April 2014 in Journal of Applied Microbiology
Verified
Journal Article
Closed access
PDF file
JAJ. Aakko
J. Aakko
BSBorja Sanchez
Borja Sanchez
MGMiguel Gueimonde
Miguel Gueimonde
SSS. Salminen
S. Salminen