Anoop Karthika

Anoop Karthika

Auto-generated profile, based on publicly available information

Anoop Karthika

Department of Pharmaceutical Analysis, JSS College of Pharmacy JSS Academy of Higher Education and Research Ooty Tamil Nadu India

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2022 in Journal of Food Measurement and Characterization
Verified
Journal Article
Closed access
PDF file
AKAnoop Karthika
Anoop Karthika
KGKowmudi Gullapalli
Kowmudi Gullapalli
NKNagappan Krishnaveni
Nagappan Krishnaveni
ARAnilakumar Kandangath Raghavan
Anilakumar Kandangath Raghavan
RPRamalingam Peraman
Ramalingam Peraman

1 February 2022 in Current Pharmaceutical Analysis
Verified
Journal Article
Closed access
PDF file
KRKarthik Rajendran
Karthik Rajendran
KAKarthika Anoop
Karthika Anoop
KNKrishnaveni Nagappan
Krishnaveni Nagappan
GSGenguchetti Mohan Sekar
Genguchetti Mohan Sekar
SRSankham Devendran Rajendran
Sankham Devendran Rajendran
Background: Extensive therapeutic drug monitoring needs an analytical method for efficient and sensitive quantification of analytes of interest in clinical pharmacology. Objective: A rapid, robust, sensitive and simple UPLC-MS/MS method to quantify Methsuximide (Ms) and N-desmethyl methsuximide/Normesuximide (MsMET) in human plasma was optimized, developed, and validated for application in a pharmacokinetic study. Method: Reverse phased chromatography was performed using Zorbax SB-C18, 4.6 x 75 mm., 3.5 μm as stationary phase, methanol and 0.1% formic acid (60:40 v/v) as mobile phase which was delivered isocratically at a flow rate of 0.9 mL/min. The sample injection volume was 5 μL. Mass spectrometric quantification of the analytes was performed using positive electrospray ionization as mass interface along with multiple reaction monitoring (MRM) as acquisition mode. Results: The selected mass transition ions for analyte, metabolite and its respective internal standards are as follows, precursor ion (m/z) and product ion (m/z): Ms (204.06 and 119.02), MsMET (190.05 and 119.82), Ms internal standard (MsIS) (209.17 and 124.02), and MsMET internal standard (MsMETIS) (195.09 and 124.16), respectively. The current method was found to be linear for Ms (60.720-6043.800 ng/mL) and MsMET (60.389 - 6010.800 ng/mL) with r2 values not less than 0.999. The mean recoveries of all analytes ranged between 71.37 and 86.38 percentage. Conclusion: This method was validated in accordance with USFDA’s bioanalytical guidelines. Conclusion: This method was validated in accordance with USFDA’s bioanalytical guidelines. This method could be applied for a routine analysis of Ms and MsMET in clinical pharmacological practice.

15 April 2026 in Journal of Food Science and Technology
Verified
Journal Article
Closed access
AKAnoop Karthika
Anoop Karthika
KGKowmudi Gullapalli
Kowmudi Gullapalli
RVRashmi Venkatesh
Rashmi Venkatesh
SMSai Varshini Magham
Sai Varshini Magham
KNKrishnaveni Nagappan
Krishnaveni Nagappan
ARAnilakumar Kandangath Raghavan
Anilakumar Kandangath Raghavan

3 May 2025 in Biomedical Chromatography
Verified
Journal Article
Closed access
GKGullapalli Kowmudi
Gullapalli Kowmudi
KAKarthika Anoop
Karthika Anoop
MVMagham Sai Varshini
Magham Sai Varshini
KNKrishnaveni Nagappan
Krishnaveni Nagappan
SKSreenath Konanki
Sreenath Konanki
PKPraveen T. Krishnamurthy
Praveen T. Krishnamurthy