Tetiana Kulko

Tetiana Kulko

Auto-generated profile, based on publicly available information

Tetiana Kulko

Національний університет «Чернігівська політехніка», Україна

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2023 in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
Verified
Journal Article
Open access
PDF file
VBVadim Bodunov
Vadim Bodunov
OGOleksandr Gai
Oleksandr Gai
TKTetiana Kulko
Tetiana Kulko
APAnatoliy Prystupa
Anatoliy Prystupa
Незважаючи на стрімкий розвиток рівня автоматизації електричних мереж, впровадження систем інтелектуальних мереж Smart Grid, залишається потреба у використанні окрім приладного обліку також розрахункових методів, зокрема для оцінки технологічних витрат електроенергії. Особливо актуальне застосування розрахункових методів в розподільних електричних мережах середньої та низької напруги. Основною причиною є економічна недоцільність автоматизованого обліку параметрів режиму на всіх ділянках та вузлах розподільних мереж. В той же час необхідне врахування впливу добової та сезонної нерівномірності графіків навантажень. Одним із методів наближеного розрахунку навантажувальної складової технологічних витрат електроенергії є метод за тривалістю максимальних втрат, аналізу якого присвячена дана робота. В ній проведено порівняльний аналіз існуючих емпіричних залежностей для оцінки тривалості максимальних втрат та визначено межі їх використання. За допомогою характерних графіків навантаження трансформаторних підстанцій 110-35/10 кВ та 10/0,4 кВ, що живлять комунально-побутове та сільськогосподарське виробниче та змішане (виробниче і комунально-побутове) устаткування споживачів, було обґрунтовано допустимість  використання емпіричних залежностей для різних діапазонів таких параметрів, як нормоване значення тривалості використання максимального навантаження, коефіцієнт форми графіка навантаження та коефіцієнт максимуму. З’ясовано, що жодна із емпіричних залежностей не забезпечує допустимої точності при оцінці тривалості максимальних втрат для графіків, які мають значну нерівномірність, що є характерним для сезонних сільськогосподарських підприємств або для джерел негарантованої генерації. Таким чином, існує потреба в додаткових дослідженнях та розробці емпіричної залежності для оцінки тривалості максимальних втрат для графіків навантаження (генерації) із значною нерівномірністю. 


14 January 2026 in TECHNICAL SCIENCES AND TECHNOLOGIES
Verified
Journal Article
Open access
PDF file
APAnatolii Prystupa
Anatolii Prystupa
YYYevhenii Yatchenko
Yevhenii Yatchenko
ARAnatolii Revko
Anatolii Revko
TKTetiana Kulko
Tetiana Kulko
АПАнатолій Приступа
Анатолій Приступа
ЄЯЄвгеній Ятченко
Євгеній Ятченко
Multicopter unmanned aerial vehicles (UAVs) are widely used in both civilian and military applications, including aerial photography, power line monitoring, cargo delivery, agriculture, and combat operations. The reliability and efficiency of their power supply systems are critical for safe operation. Battery failures during flight, such as unexpected discharge or overheating, can lead to emergency landings, loss of the vehicle, or even fire and explosion hazards. Standard battery management systems (BMS) used in commercial multicopters are limited to basic protection functions and do not provide accurate residual capacity estimation, remaining flight time prediction, or battery degradation tracking. A separate category includes UAVs operating without built-in BMS, which is typical for FPV drones and tactical unmanned systems where weight minimization and prevention of sudden power cutoff are critical factors. Therefore, the development of an effective power supply parameter monitoring system is a relevant scientific and technical task. Existing monitoring solutions are typically limited to measuring the total battery current and voltage, without providing per-channel analysis of individual motor power circuits. This approach does not allow early detection of anomalies in individual drive systems, load imbalance between motors, or degradation of specific power circuit components. The problem is particularly acute for UAVs operating under extreme conditions: low or high ambient temperatures, significant load fluctuations, and batteries with varying degrees of wear. The research objective is to develop and substantiate the hardware architecture of a power circuit parameter monitoring system for a multicopter drone that provides current and voltage measurement in individual motor channels with integration into the existing control system based on the NVIDIA Jetson Nano single-board computer and the Pixhawk 6C flight controller. Achieving this objective will enable early detection of anomalies in individual power circuits, improve flight safety, and extend battery service life through informed energy management. A modular monitoring system architecture consisting of two main subsystems has been proposed: a power circuit parameter measurement subsystem and a data acquisition and processing subsystem. ACS758 Hall effect current sensors have been selected for motor current measurement, providing galvanic isolation, no power losses in the power circuit, and a measurement range of up to 50 A. For precision voltage measurement, INA226 integrated circuits with 16-bit ADC resolution and ±0.1% accuracy have been chosen, supporting up to 16 devices on a single I2C bus. An I2C bus organization scheme with unique addressing of five devices (four INA226 modules and an ADS1115 ADC) has been developed, enabling per-channel monitoring of four motor power circuits. Integration with the Pixhawk 6C flight controller is provided via the MAVLink protocol through a USB-UART interface with an HW-597 logic level converter. A comparative analysis of the selected components against alternative solutions has been performed, and system limitations including I2C bus constraints, measurement channel errors, electromagnetic interference effects, and scalability considerations have been discussed. The developed hardware architecture represents a novel approach to per-channel power monitoring in multicopter UAVs, addressing the gap between basic BMS functionality and the requirements of advanced diagnostics. The proposed system provides current and voltage measurement in each motor channel, enabling determination of instantaneous power consumption and load balance monitoring between motors. Unlike typical solutions limited to total battery current measurement, per-channel monitoring creates prerequisites for early detection of anomalies in individual drone components. The practical significance lies in the ability to detect motor or ESC degradation at an early stage, prevent in-flight failures, and optimize battery usage patterns — directly fulfilling the stated research objective of improving flight safety and extending battery life. Future research directions include the development of algorithmic support for estimating state of charge (SoC) and state of health (SoH) of the battery based on per-channel monitoring data, as well as experimental studies of the proposed system accuracy and reliability under real flight conditions.