16 December 2019 in Engineering Reports
The increase in population especially in third world countries demands taller, more flexible, and lighter buildings. Most of these countries are subjected to a high risk of earthquakes, which requires more control of building seismic response. However, several techniques exist to minimize the vibrations induced by an earthquake shock. This paper will discuss the effectiveness of using friction dampers as a passive dissipative device and proposes some design optimization of the number and position of dampers in the building. Friction dampers offer a supplemental damping in conjunction with appropriate stiffness, offering an innovative and attractive solution for the seismic response control of tall structures in risky areas. The originality of this work is in the detailed seismic study of an asymmetric reinforced concrete (RC) building, located in a risky seismic zone and using real earthquake seismic waves. The seismic response of this dissipative structural method is compared with the response of the conventional method (shear wall system) for the high rise building. To accomplish this objective, a nonlinear modal time history analysis using the El Centro earthquake record for a 40‐storey RC high rise building, is performed with four different damper type formats using ETABS software. To illustrate the response improvement by dampers, storey accelerations, storey displacements, base shear forces, and storey drifts are compared with a conventional fixed base system (shear wall system) for the same building. Results show that using an optimum position and number of dampers, a tall building can remain operational during a seism.
15 April 2019 in Physical Review E
Roots provide basic functions to plants such as water and nutrient uptake and anchoring in soil. The growth and development of root systems contribute to colonizing the surrounding soil and optimizing the access to resources. It is generally known that the variability of plant root architecture results from the combination of genetic, physiological, and environmental factors, in particular soil mechanical resistance. However, this last factor has never been investigated at the soil grain scale for roots. In this paper, we are interested in the effect of the disordered texture of granular soils on the evolution of forces experienced by the root cap during its growth. We introduce a numerical model in which the root is modeled as a flexible self-elongating tube that probes a soil composed of solid particles. By means of extensive simulations, we show that the forces exerted on the root cap reflect interparticle force chains. Our simulations also show that the mean force declines exponentially with root flexibility, the highest force corresponding to the soil hardness. Furthermore, we find that this functional dependence is characterized by a single dimensionless parameter that combines granular structure and root bending stiffness. This finding will be useful to further address the biological issues of mechanosensing and thigmomorphogenesis in plant roots.
1 January 2021 in Structural Durability & Health Monitoring
Seismic earthquakes are a real danger for the construction evolution of high rise buildings. The rate of earthquakes around the world is noteworthy in a wide range of construction areas. In this study, we present the dynamic behavior of a high-rise RC building with dynamic isolators (lead-rubber-bearing), in comparison with a traditional shear wall system of the same building. Seismic isolation has been introduced in building construction to increase the structural stability and to protect the non-structural components against the damaging effects of an earthquake. In order to clarify the influence of incorporating lead rubber bearing isolators in the seismic response and in reducing seismic damages; a comparative study is performed between a fixed base system (shear wall system) and an isolated base system (Lead Rubber Bearing) on an irregular high rise reinforced concrete (RC) building located in Beirut consisting of 48 storeys almost asymmetric orthogonally. For this purpose, a non-linear analysis of a real earthquake acceleration record (EI Centro seismic signal) is conducted, so that the mode shapes, the damping ratio and the natural frequencies of the two models are obtained using ETABS software. The results prove a substantial elongation of the building period, as well as a reduction in the building displacement, the roof acceleration, the inter-storey drift ratio and the base shear force of isolated building relative to fixed-base building. This study proves that this technology is applicable to high rise buildings with acceptable results.
30 June 2017 in EPJ Web of Conferences
EPJ Web of Conferences, open-access proceedings in physics and astronomy