V. O. Karpunin

V. O. Karpunin

Auto-generated profile, based on publicly available information

V. O. Karpunin

Gammamed-Soft, Ltd

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
Verified
Journal Article
Open access
PDF file
VKV.O. Karpunin
V.O. Karpunin
DOD.G. Orlov
D.G. Orlov
The authors propose the method that is intended for automating patient treatment technological process in a proton therapy center and based on a decision support system. The developed information system provides the implementation of the proton therapy protocols. The technological process of the proton therapy is strictly regulated. It includes not only the process of therapy itself (irradiation of the patient), but also the preliminary stages of treatment, as well as the stages following the irradiation process. Proton therapy centers use information systems, such as radiological and hospital information systems (oncology information systems), that provide information support for separate stages. At the moment, there is no system that controls the entire technological process in a proton therapy center. The proposed system ensures that the operator complies with the protocol of the treatment’s stage and supports the entire technological process of the proton therapy. The system sets the schedule of stages, order and possibility of their parallel implementation, determines the conditions for allowing the start of the stage, provides the subsystems with the protocol of the stage and necessary data of protocol to manage the stage by the operator, and also records the results of the completed stage. The system is built on the “client-server” technology. The server has a software part (that implements the concept the server) and a database. For each operator workstation that manages the stage, the client software of the system is additionally installed. The paper describes an approach to creating a decision support system for the personnel of a proton therapy center. Such a system provides the correct implementation and sequence of the proton therapy stages. The system has been included in the project of the Research Proton Therapy Center for Ophthalmic Oncology at Saint Petersburg Nuclear Physics Institute of National Research Center “Kurchatov Institute”. The necessary information is transmitted from the system to the proton therapy center equipment via radiological and hospital information systems using standard protocols. It allows the solution to serve as a part of any automated control system of a radiation therapy center (not only for proton therapy).

19 October 2026 in Russian journal of neurosurgery
Verified
Journal Article
Open access
PDF file
DZDmitry Zakondyrin
Dmitry Zakondyrin
VKV. O. Karpunin
V. O. Karpunin
DDDaria Dolotova
Daria Dolotova
SDSergey Dydykin
Sergey Dydykin
YVYu. L. Vasyliev
Yu. L. Vasyliev
ВКВ. В. Крылов
В. В. Крылов
Background. Navigation systems today have become an integral part of most neurosurgical interventions, including those on the spine. Aim. Development of a methodology for laboratory testing of the accuracy of navigation systems during surgical interventions on the spine and its evaluation for the domestic optical frameless navigation system “Multitrack”. Materials and methods. Using enbalmed human specimens, a posterior approach to the cervical, thoracic and lumbar spine was simulated. In each part of the spine, titanium miniscrews were implanted in the area of anatomical structures (target points) that were most significant when performing neurosurgical interventions on the spine. Next, a series of experimental measurements of navigation accuracy were performed to determine the system error in the axial and sagittal planes. Results. The average registration error was 0.3 [0.21; 0.43] mm. Statistical analysis showed the absence of a linear correlation between the magnitude of the registration error and the error in hitting the target points, both in the axial (r = 0.125; 95 % confidence interval 0.016–0.242; р = 0.03) and sagittal (r = 0.113; 95 % confidence interval –0.003…0.222; р = 0.051) planes. The average error in hitting the target points was 0.7 [0.4; 1.0] mm in the axial plane and 0.6 [0.3; 1.0] mm – in the sagittal. Conclusion. In a series of experiments, the Multitrack navigation system demonstrated accuracy sufficient to perform most vertebrological surgical interventions.

9 July 2025 in Russian Journal of Operative Surgery and Clinical Anatomy
Verified
Journal Article
Closed access
OKOleg Ivanovich Kit
Oleg Ivanovich Kit
DZDmitry Zakondyrin
Dmitry Zakondyrin
AGA.A. Grin
A.A. Grin
ERE.E. Rostorguev
E.E. Rostorguev
SDSergey Dydykin
Sergey Dydykin
ILIrina Lakman
Irina Lakman
Background. The use of a combination of surgical decompression of the spinal cord and stabilization of the spine with subsequent conformal radiation therapy of tumor remnants in the treatment of patients with metastatic vertebral tumors makes it relevant to calculate and visualize the volume of a partially removed metastatic vertebral tumor without intraoperative X-ray computed tomography (CT). Objective. The purpose of the study was to evaluate the algorithm for calculating the volume of the cytoreductively removed part of the body of the vertebra affected by the tumor using optical navigation. Material and methods. On 6 human cadavers, a typical posterior approach and navigated resection of the vertebral body from a posterolateral transpedicular approach at several levels were simulated. A total of 15 patients underwent palliative surgical treatment for metastatic tumors of the spine, including decompressive and stabilizing intervention using a navigation system. During the anatomical experiment, the volume of the cavity after removal of a part of the vertebral body was calculated using a navigation system. Then, the volumes of the resected part of the vertebra, calculated during the anatomical experiment or during the surgical intervention, were compared with the results calculated later using the CT neuroimaging data. Results. When analyzing the data from the laboratory and clinical phases of the experiment, it was found that the calculated indicators of the volume of the removed part of the vertebral bodies at different levels, calculated on the basis of intraoperative measurements and according to the results of control CT, do not differ statistically significantly. Conclusion. The navigation system under the conditions of experimental interventions in biological models and in the surgical treatment of patients with metastatic spinal involvement showed high accuracy of software algorithms in calculating the volume of cytoreduction of tumor tissue.

16 November 2025 in Russian Neurosurgical Journal named after Professor A. L. Polenov
Verified
Journal Article
Open access
PDF file
OKOleg Ivanovich Kit
Oleg Ivanovich Kit
DZDmitry Zakondyrin
Dmitry Zakondyrin
AGA. A. Green
A. A. Green
ERE. E. Rostorguev
E. E. Rostorguev
YVYuriy Vasil'ev
Yuriy Vasil'ev
VKV. O. Karpunin
V. O. Karpunin
INTRODUCTION. Occipitospondylodesis or craniovertebral fixation is a common technology for surgical treatment of various pathological processes in the area of the first and second cervical vertebrae, leading to instability of the craniovertebral joint. AIM . Analysis of the possibilities of using computer navigation in performing occipitospondylodesis with screw fixation of cervical vertebrae in tumor pathology. MATERIALS AND METHODS. On 3 frozen head-neck human specimens the insertion of screws of C1–C4 vertebrae was simulated. From the posterior approach 6 patients with metastatic lesions of C1-C2 vertebrae were operated with the implementation of screw occipitospondylodesis. RESULTS. In patients with tumors of the upper cervical vertebrae, implantation of screws at the C1–C2 level was not relevant during occipitospondylodesis. Using only preoperative CT data for vertebral registration required registration of each vertebra. In cadaveric material, when installing screws in the lateral masses of the vertebrae, the use of computer navigation was not required, in contrast to the installation of pedicle screws. In 2 patients operated on using the free-hand technique, asymptomatic malpositions of 2 (12.5 %) screws in the lateral masses were detected; when using computer navigation, no malpositions of screws in the lateral masses and pedicles were detected. CONCLUSION . The use of computer navigation during occipitospondylodesis surgery in patients with craniovertebral tumors and the lack of extensive experience in screw fixation in the cervical spine is justified both for transpedicular fixation and for installing screws in the lateral masses of subaxial vertebrae, as it allows avoiding asymptomatic malpositions.