Mohammad Reza Mahmoudi

Mohammad Reza Mahmoudi

Auto-generated profile, based on publicly available information

Mohammad Reza Mahmoudi

Statistics Department, Faculty of Science, Fasa University, Fasa, Iran

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AAAli Reza Abbasi
Ali Reza Abbasi
MMMohammad Reza Mahmoudi
Mohammad Reza Mahmoudi
MAMohammad Mehdi Arefi
Mohammad Mehdi Arefi
Monitoring of winding faults is of great significance for the assessment of the transformer maintenance status. In this study, the time series analysis is combined with frequency response analysis (FRA) for better interpretation and analysis of FRA results. Here, healthy baseline residual data are modeled using the time series analysis for faults detection of the transformer winding. Different statistical software, such as R 4.0.2 and ITSM2000, are used to analyze measured data. To detect the transformer’s winding faults, various analyses, such as the autocorrelation and partial autocorrelation functions plot, the Box–Pierce test, the Ljung–Box test, the McLeod–Li test, the turning points test, the Wallis and Moore phase–frequency test, and the Jarque–Bera test, and the order of minimum corrected Akaike’s information criteria are used. The simulation results show that the suggested method is able to classify and discriminate mechanical and electrical faults of the transformer’s winding with good accuracy.

3 February 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
AHAbdoallah Hosseini
Abdoallah Hosseini
AAAli Abbasi
Ali Abbasi
AAAli Reza Abbasi
Ali Reza Abbasi
MMMohammad Reza Mahmoudi
Mohammad Reza Mahmoudi
Power transformers serve as critical components in electrical transmission networks, continuously exposed to severe electromechanical stresses that lead to winding faults including Axial Displacement (AD), Radial Deformation (RD), and inter-disk Short Circuit (SC). Early detection of these faults is crucial for preventing catastrophic failures and ensuring grid reliability. While Frequency Response Analysis (FRA) has gained global acceptance as a sensitive diagnostic tool, its primary challenge lies in the subjective interpretation of complex frequency responses. This paper presents an automated, quantitative framework that leverages two parallel visualization methodologies: Principal Component Analysis (PCA) for optimal feature compression and noise reduction within hybrid amplitude-phase feature space, and Fuzzy Clustering Analysis (FCA) for managing uncertainties in transitional and combined fault conditions. The proposed approach implements a structured two-stage identification process: initially distinguishing healthy from faulty states, followed by specific fault classification. Experimental validation on a 1 MVA transformer under various fault severity levels demonstrates outstanding performance, with PCA and FCA achieving accuracies of 98.9% and 99.0%, respectively. The dual visualization system independently presents results from both methods, significantly reducing dependency on specialized expertise and enabling clearer, more objective interpretation. This research represents a significant step toward standardizing FRA interpretation and offers a practical, reliable solution for transformer condition assessment in industrial applications.