Anna-Maria Shiarli

Anna-Maria Shiarli

Auto-generated profile, based on publicly available information

Anna-Maria Shiarli

Institute of Cancer Research and The Royal Marsden NHS Foundation Trust

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
BEBjörn Eiben
Björn Eiben
JBJenny Bertholet
Jenny Bertholet
HTHuong Elena Tran
Huong Elena Tran
AWAndreas Wetscherek
Andreas Wetscherek
ASAnna-Maria Shiarli
Anna-Maria Shiarli
JMJamie R McClelland
Jamie R McClelland
Objective. Respiratory motion of lung tumours and adjacent structures is challenging for radiotherapy. Online MR-imaging cannot currently provide real-time volumetric information of the moving patient anatomy, therefore limiting precise dose delivery, delivered dose reconstruction, and downstream adaptation methods. Approach. We tailor a respiratory motion modelling framework towards an MR-Linac workflow to estimate the time-resolved 4D motion from real-time data. We develop a multi-slice acquisition scheme which acquires thick, overlapping 2D motion-slices in different locations and orientations, interleaved with 2D surrogate-slices from a fixed location. The framework fits a motion model directly to the input data without the need for sorting or binning to account for inter- and intra-cycle variation of the breathing motion. The framework alternates between model fitting and motion-compensated super-resolution image reconstruction to recover a high-quality motion-free image and a motion model. The fitted model can then estimate the 4D motion from 2D surrogate-slices. The framework is applied to four simulated anthropomorphic datasets and evaluated against known ground truth anatomy and motion. Clinical applicability is demonstrated by applying our framework to eight datasets acquired on an MR-Linac from four lung cancer patients. Main results. The framework accurately reconstructs high-quality motion-compensated 3D images with 2 mm 3 isotropic voxels. For the simulated case with the largest target motion, the motion model achieved a mean deformation field error of 1.13 mm. For the patient cases residual error registrations estimate the model error to be 1.07 mm (1.64 mm), 0.91 mm (1.32 mm), and 0.88 mm (1.33 mm) in superior-inferior, anterior-posterior, and left-right directions respectively for the building (application) data. Significance. The motion modelling framework estimates the patient motion with high accuracy and accurately reconstructs the anatomy. The image acquisition scheme can be flexibly integrated into an MR-Linac workflow whilst maintaining the capability of online motion-management strategies based on cine imaging such as target tracking and/or gating.

1 June 2021 in Lung Cancer
Verified
Journal Article
Closed access
JCJoyce Cheng
Joyce Cheng
MPMinal Padden-Modi
Minal Padden-Modi
RKRachel Kirby
Rachel Kirby
NTNicola Twyman
Nicola Twyman
ASAnna-Maria Shiarli
Anna-Maria Shiarli
KJKamalram Thippu Jayaprakash
Kamalram Thippu Jayaprakash