1 December 2022 in Radiology
Fractional intracellular volume–derived Vascular, Extracellular, and Restricted Diffusion for Cytometry in Tumor analysis of multiparametric MRI findings resulted in better classification of clinic... Background In men suspected of having prostate cancer (PCa), up to 50% of men with positive multiparametric MRI (mpMRI) findings (Prostate Imaging Reporting and Data System [PI-RADS] or Likert scor...
17 December 2018 in European Radiology
Objectives Volume of necrosis in Wilms tumour is informative of chemotherapy response. Contrast-enhanced T1-weighted MRI (T1w) provides a measure of necrosis using gadolinium. This study aimed to develop a non-invasive method of identifying non-enhancing (necrotic) tissue in Wilms tumour. Methods In this single centre, retrospective study, post-chemotherapy MRI data from 34 Wilms tumour patients were reviewed (March 2012–March 2017). Cases with multiple b value diffusion-weighted imaging (DWI) and T1w imaging pre- and post-gadolinium were included. Fractional T1 enhancement maps were generated from the gadolinium T1w data. Multiple linear regression determined whether fitted parameters from a mono-exponential model (ADC) and bi-exponential model (IVIM – intravoxel incoherent motion) (D, D*, f) could predict fractional T1 enhancement in Wilms tumours, using normalised pre-gadolinium T1w (T1wnorm) signal as an additional predictor. Measured and predicted fractional enhancement values were compared using the Bland-Altman plot. An optimum threshold for separating necrotic and viable tissue using fractional T1 enhancement was established using ROC. Results ADC and D (diffusion coefficient) provided the strongest predictors of fractional T1 enhancement in tumour tissue (p < 0.001). Using the ADC-T1wnorm model (adjusted R2 = 0.4), little bias (mean difference = − 0.093, 95% confidence interval = [− 0.52, 0.34]) was shown between predicted and measured values of fractional enhancement and analysed via the Bland-Altman plot. The optimal threshold for differentiating viable and necrotic tissue was 33% fractional T1 enhancement (based on measured values, AUC = 0.93; sensitivity = 85%; specificity = 90%). Conclusions Combining ADC and T1w imaging predicts enhancement in Wilms tumours and reliably identifies and measures necrotic tissue without gadolinium. Key Points • Alternative method to identify necrotic tissue in Wilms tumour without using contrast agents but rather using diffusion and T 1 weighted MRI. • A method is presented to visualise and quantify necrotic tissue in Wilms tumour without contrast. • The proposed method has the potential to reduce costs and burden to Wilms tumour patients who undergo longitudinal follow-up imaging as contrast agents are not used.
16 March 2023 in European Journal of Radiology
VERDICT (Vascular, Extracellular, Restricted Diffusion for Cytometry in Tumours) MRI is a multi b-value, variable diffusion time DWI sequence that allows generation of ADC maps from different b-value and diffusion time combinations. The aim was to assess precision of prostate ADC measurements from varying b-value combinations using VERDICT and determine which protocol provides the most repeatable ADC. Forty-one men (median age: 67.7 years) from a prior prospective VERDICT study (April 2016-October 2017) were analysed retrospectively. Men who were suspected of prostate cancer and scanned twice using VERDICT were included. ADC maps were formed using 5b-value combinations and the within-subject standard deviations (wSD) were calculated per ADC map. Three anatomical locations were analysed per subject: normal TZ (transition zone), normal PZ (peripheral zone), and index lesions. Repeated measures ANOVAs showed which b-value range had the lowest wSD, Spearman correlation and generalized linear model regression analysis determined whether wSD was related to ADC magnitude and ROI size. The mean lesion ADC for b0b1500 had the lowest wSD in most zones (0.18-0.58x10-4 mm2/s). The wSD was unaffected by ADC magnitude (Lesion: p = 0.064, TZ: p = 0.368, PZ: p = 0.072) and lesion Likert score (p = 0.95). wSD showed a decrease with ROI size pooled over zones (p = 0.019, adjusted regression coefficient = -1.6x10-3, larger ROIs for TZ versus PZ versus lesions). ADC maps formed with a maximum b-value of 500 s/mm2 had the largest wSDs (1.90-10.24x10-4 mm2/s). ADC maps generated from b0b1500 have better repeatability in normal TZ, normal PZ, and index lesions.
8 March 2022 in British Journal of Radiology
Objective: To develop a phantom system which can be integrated with an automated injection system, eliminating the experimental variability that arises with manual injection; for the purposes of pulse sequence testing and metric derivation in hyperpolarised 13C-MR. Methods: The custom dynamic phantom was machined from Ultem and filled with a nicotinamide adenine dinucleotide and lactate dehydrogenase mixture dissolved in phosphate buffered saline. Hyperpolarised [1-13C]-pyruvate was then injected into the phantom (n = 8) via an automated syringe pump and the conversion of pyruvate to lactate monitored through a 13C imaging sequence. Results: The phantom showed low coefficient of variation for the lactate to pyruvate peak signal heights (11.6%) and dynamic area-under curve ratios (11.0%). The variance for the lactate dehydrogenase enzyme rate constant (kP) was also seen to be low at 15.6%. Conclusion: The dynamic phantom demonstrates high reproducibility for quantification of 13C-hyperpolarised MR-derived metrics. Establishing such a phantom is needed to facilitate development of hyperpolarsed 13C-MR pulse sequenced; and moreover, to enable multisite hyperpolarised 13C-MR clinical trials where assessment of metric variability across sites is critical. Advances in knowledge: The dynamic phantom developed during the course of this study will be a useful tool in testing new pulse sequences and standardisation in future hyperpolarised work.
2 July 2020 in Magnetic Resonance Materials in Physics, Biology and Medicine
Objective: ADC (Apparent Diffusion Coefficient) derived from Diffusion-Weighted Imaging (DWI) has shown promise as a non-invasive quantitative imaging biomarker in Wilms’ tumours. However, many non-Gaussian models could be applied to DWI. This study aimed to compare the suitability of four diffusion models (mono exponential, IVIM [Intravoxel Incoherent Motion], stretched exponential, and kurtosis) in Wilms’ tumours and the unaffected contralateral kidneys. Materials and methods: DWI data were retrospectively reviewed (110 Wilms’ tumours and 75 normal kidney datasets). The goodness of fit for each model was measured voxel-wise using Akaike Information Criteria (AIC). Mean AIC was calculated for each tumour volume (or contralateral normal kidney tissue). One-way ANOVAs with Greenhouse–Geisser correction and post hoc tests using the Bonferroni correction evaluated significant differences between AIC values; the lowest AIC indicating the optimum model. Results: IVIM and stretched exponential provided the best fits to the Wilms’ tumour DWI data. IVIM provided the best fit for the normal kidney data. Mono exponential was the least appropriate fitting method for both Wilms’ tumour and normal kidney data. Discussion: The diffusion weighted signal in Wilms’ tumours and normal kidney tissue does not exhibit a mono-exponential decay and is better described by non-Gaussian models of diffusion.