1 November 2020 in Journal of Structural Engineering
This paper presents the results of an experimental study that was conducted to investigate the postfire seismic behavior of reinforced concrete columns. Five full-scale, flexure-critical code-complying (e.g., ACI 318-14) cast-in-place reinforced concrete columns were tested to failure under a constant axial load and reversed cyclic lateral displacements after being exposed to an ISO-834 standard fire for 30, 60, and 90 min. Other than the effects of the duration of the fire exposure, the effects of the thickness of the concrete cover (25 and 40 mm) on the structural performance was also investigated for the short fire exposure duration (30 min). The responses of the columns were analyzed in terms of lateral load-displacement relationships, ductility, stiffness, energy dissipation capacities, and residual displacements. The test results indicated that the fire exposure reduced the lateral load capacity of the columns, whereas the deformability capabilities were found to be satisfactory in terms of a structural response. It was also observed that the thickness of the concrete cover had only a slight influence on the postfire seismic behavior of the columns. Furthermore, a numerical study was conducted to predict the load-displacement response of the fire exposed columns. The comparison of the experimentally and numerically obtained load-displacement relationships indicated that the principles of structural mechanics usually applied to conventional columns are also valid for the columns exposed to fire.
13 May 2026 in Bulletin of Earthquake Engineering
Past destructive earthquakes have highlighted the vulnerability of substandard reinforced concrete (RC) buildings that do not comply with seismic design codes. To ensure safety of the occupants and mitigate the losses, these buildings should be urgently retrofitted or rebuilt. This study evaluates conventional retrofitting techniques (integration of new shear walls, and RC jacketing of existing columns), and innovative techniques (fiber-reinforced polymer confinement, and RC thin jacketing with FRP confinement of existing RC columns) in enhancing seismic performance and reducing potential losses. For this purpose, an existing RC moment frame building representing the common characteristics of substandard RC frame buildings in Türkiye was considered. After performing seismic assessment of the building and demonstrating its unsatisfactory performance, retrofit designs were made to satisfy the target seismic performance limit (life safety). A series of nonlinear structural analyses were performed in accordance with the incremental dynamic analysis technique for both the as-built and the retrofitted states. The typical characteristics of substandard buildings (i.e., low strength concrete, lack of confinement, tendency of longitudinal bars to buckle, etc.) were considered during the numerical modelling. Fragilities were generated for immediate occupancy , life safety , and collapse prevention limit states. As the ground motion intensity measure, the Peak Ground Acceleration (PGA) and Peak Ground Velocity (PGV) were utilized. Furthermore, cost-benefit analyses were conducted to assess the relative effectiveness of alternative retrofitting techniques in terms of mitigating potential losses. All retrofitting strategies were found to become economically beneficial within a short time horizon, ranging between 3 and 7 years.