Shawn K. Kelly

Shawn K. Kelly

Auto-generated profile, based on publicly available information

Shawn K. Kelly

VA Pittsburgh Healthcare System

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 1997 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SBS.B. Baumann
S.B. Baumann
DWD.R. Wozny
D.R. Wozny
SKS.K. Kelly
S.K. Kelly
FMF.M. Meno
F.M. Meno
The electrical conductivity of human cerebrospinal fluid (CSF) from seven patients was measured at both room temperature (25 degrees C) and body temperature (37 degrees C). Across the frequency range of 10 Hz-10 kHz, room temperature conductivity was 1.45 S/m, but body temperature conductivity was 1.79 S/m, approximately 23% higher. Modelers of electrical sources in the human brain have underestimated human CSF conductivity by as much as 44% for nearly two decades, and this should be corrected to increase the accuracy of source localization models.

1 December 2003 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
JRJoseph Rizzo
Joseph Rizzo
JWJohn Wyatt
John Wyatt
JLJohn Loewenstein
John Loewenstein
SKShawn Kelly
Shawn Kelly
DSDoug Shire
Doug Shire
Purpose. This work is part of a feasibility assessment of a retinal prosthesis as a means to restore vision to patients with blindness caused by retinitis pigmentosa. The primary goal was to assess the concordance of the form of induced perception and the pattern of electrical stimulation of the retina, and the reproducibility of the responses. methods. Five volunteers with severe retinitis pigmentosa and one with normal vision were studied. A companion paper in this issue provides details on demographics, visual function, surgical methods, general stimulation strategy, and data analysis. Volunteers were awake during surgery while a 10-μm-thick, microfabricated electrode array was placed on the retina. The array was connected to extraocular current sources that delivered charges to 50-, 100-, and 400-μm-diameter electrodes. Negative control trials were randomly included. Perceptual quality was judged by the similarity between the form of stimulation and perception (i.e., accuracy) and the reproducibility of responses. results. Only 1 of 40 control tests yielded a false-positive result. On average, volunteers 3, 5, and 6 reported percepts that matched the stimulation pattern 48% and 32% of the time for single- and multiple-electrode trials, respectively. Two-point discrimination in the best cases may have been achieved in two blind subjects using (center-to-center) electrode separation of 600 and 1960 μm. Reproducibility was achieved 66% of the time in the blind subjects. By comparison, in the normal-sighted subject, perceptual form was reported accurately 57% of the time, with 82% reproducibility, and two-point discrimination may have been achieved in one trial with 620-μm electrode spacing and in two trials each with 1860- and 2480-μm electrode spacing. In subjects 5 and 6, perceptual size was inconsistently related to the charge, although relatively large differences in charge (median: 0.55 microcoulombs [μC]) between two trials produced differently sized percepts. Longer stimuli did not produce rounder percepts. conclusions. Single percepts induced by single-electrode stimulation were relatively small, but the form of percepts, especially after multielectrode stimulation, often did not match the stimulation pattern, even in a normal-sighted volunteer. Reproducible percepts were more easily generated than those that matched the stimulation pattern.

1 December 2003 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
JRJoseph Rizzo
Joseph Rizzo
JWJohn Wyatt
John Wyatt
JLJohn Loewenstein
John Loewenstein
SKShawn Kelly
Shawn Kelly
DSDoug Shire
Doug Shire
Purpose. To report methods for performing epiretinal electrical stimulation with microfabricated electrode arrays and determining perceptual thresholds on awake human volunteers during acute surgical trials. methods. Four hypotheses were tested: (1) epiretinal stimulation can be performed during acute experiments without obviously damaging the retina or degrading vision or the health of the eye; (2) perception can be obtained 50% of the time in blind patients with charge densities below published safety limits; (3) the minimal charge needed to induce perception would be higher in patients with more severe retinal degeneration; and (4) threshold charge would be lower at shorter stimulus durations. Five subjects with severe blindness from retinitis pigmentosa and one with normal vision (who underwent enucleation of the eye because of orbital cancer) were studied. Electrical stimulation of the retina was performed on awake volunteers by placing a single 250-μm diameter handheld needle electrode or a 10-μm thick microfabricated array of iridium oxide electrodes (400-, 100-, or 50-μm diameter) on the retina. Current sources outside the eye delivered charge to the electrodes. Assessment of damage was made by observing the clinical appearance of the eyes, comparing pre- and postoperative visual acuity, obtaining retinal histology in one case, and comparing perceptual thresholds with published safety limits. results. No clinically visible damage to the eye or loss of vision occurred. Even at sites removed from stimulation, histology revealed swollen photoreceptor inner and outer segments, which were believed to be nonspecific findings. Percepts could not be reliably elicited with 50-μm diameter electrodes using safe charges in one blind patient. With the two larger electrodes, only the normal-sighted patient had thresholds at charge densities below 0.25 and 1.0 millicoulombs (mC)/cm2 for 400- and 100-μm diameter electrodes, respectively, which is one seemingly reasonable estimate of safety derived from the product of charge per phase and charge density per phase. In blind patients, thresholds always exceeded these levels, although most were close to these limits in patient 6. The range of charge density thresholds with the 400-μm electrode in blind patients was 0.28 to 2.8 mC/cm2. The normal-sighted patient had a threshold of 0.08 mC/cm2 with a 400-μm electrode, roughly one quarter of the lowest threshold in the blind patients. Strength–duration curves obtained in two blind patients revealed the lowest threshold charge at the 0.25- or 1.0-ms stimulus duration. conclusions. Threshold charge densities in severely blind patients were substantially higher than that in a normal-sighted patient. Charge densities in blind patients always exceeded one seemingly reasonable estimate of safe stimulation. The potential adversity of long-term stimulation of the retina by a prosthesis has yet to be determined.

28 April 2009 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
DSDouglas Shire
Douglas Shire
SKShawn K. Kelly
Shawn K. Kelly
JCJinghua Chen
Jinghua Chen
PDPatrick Doyle
Patrick Doyle
MGMarcus D. Gingerich
Marcus D. Gingerich
JRJoseph F. Rizzo
Joseph F. Rizzo
A wirelessly operated, minimally invasive retinal prosthesis was developed for preclinical chronic implantation studies in Yucatan minipig models. The implant conforms to the outer wall of the eye and drives a microfabricated polyimide stimulating electrode array with sputtered iridium oxide electrodes. This array is implanted in the subretinal space using a specially designed ab externo surgical technique that fixes the bulk of the prosthesis to the outer surface of the sclera. The implanted device is fabricated on a host polyimide flexible circuit. It consists of a 15-channel stimulator chip, secondary power and data receiving coils, and discrete power supply components. The completed device is encapsulated in poly(dimethylsiloxane) except for the reference/counter electrode and the thin electrode array. In vitro testing was performed to verify the performance of the system in biological saline using a custom RF transmitter circuit and primary coils. Stimulation patterns as well as pulse strength, duration, and frequency were programmed wirelessly using custom software and a graphical user interface. Wireless operation of the retinal implant has been verified both in vitro and in vivo in three pigs for more than seven months, the latter by measuring stimulus artifacts on the eye surface using contact lens electrodes.

22 August 2011 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SKShawn K. Kelly
Shawn K. Kelly
DSDouglas Shire
Douglas Shire
JCJinghua Chen
Jinghua Chen
PDPatrick Doyle
Patrick Doyle
MGMarcus Gingerich
Marcus Gingerich
JRJoseph Rizzo
Joseph Rizzo
A miniaturized, hermetically encased, wirelessly operated retinal prosthesis has been developed for preclinical studies in the Yucatan minipig, and includes several design improvements over our previously reported device. The prosthesis attaches conformally to the outside of the eye and electrically drives a microfabricated thin-film polyimide array of sputtered iridium oxide film electrodes. This array is implanted into the subretinal space using a customized ab externo surgical technique. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip and discrete circuit components. Feedthroughs in the case connect the stimulator chip to secondary power and data receiving coils on the eye and to the electrode array under the retina. Long-term in vitro pulse testing of the electrodes projected a lifetime consistent with typical devices in industry. The final assembly was tested in vitro to verify wireless operation of the system in physiological saline using a custom RF transmitter and primary coils. Stimulation pulse strength, duration, and frequency were programmed wirelessly from a Peripheral Component Interconnect eXtensions for Instrumentation (PXI) computer. Operation of the retinal implant has been verified in two pigs for up to five and a half months by detecting stimulus artifacts generated by the implanted device.

24 January 2011 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
SKShawn K. Kelly
Shawn K. Kelly
JWJohn L. Wyatt
John L. Wyatt
This paper presents a power-efficient neural stimulator integrated circuit, designed to take advantage of our understanding of iridium-oxide electrode impedance. It efficiently creates a programmable set of voltage supplies directly from a secondary power telemetry coil, then switches the target electrode sequentially through the voltage steps. This sequence of voltages mimics the voltage of the electrode under the constant current drive, resulting in approximately constant current without the voltage drop of the more commonly used linear current source. This method sacrifices some precision, but drastically reduces the series losses seen in traditional current sources and attains power savings of 53%-66% compared to these designs. The proof-of-concept circuit consumes 125 μW per electrode and was fabricated in a 1.5-μm CMOS process, in a die area of 4.76 mm2.