1 August 2016 in Journal of Biomechanics
Transcatheter aortic valve implantation (TAVI) can treat symptomatic patients with calcific aortic stenosis. However, the severity and distribution of the calcification of valve leaflets can impair the TAVI efficacy. Here we tackle this issue from a biomechanical standpoint, by finite element simulation of a widely adopted balloon-expandable TAVI in three models representing the aortic root with different scenarios of calcific aortic stenosis. We developed a modeling approach realistically accounting for aortic root pressurization and complex anatomy, detailed calcification patterns, and for the actual stent deployment through balloon-expansion. Numerical results highlighted the dependency on the specific calcification pattern of the "dog-boning" of the stent. Also, local stent distortions were associated with leaflet calcifications, and led to localized gaps between the TAVI stent and the aortic tissues, with potential implications in terms of paravalvular leakage. High stresses were found on calcium deposits, which may be a risk factor for stroke; their magnitude and the extent of the affected regions substantially increased for the case of an "arc-shaped" calcification, running from commissure to commissure. Moreover, high stresses due to the interaction between the aortic wall and the leaflet calcifications were computed in the annular region, suggesting an increased risk for annular damage. Our analyses suggest a relation between the alteration of the stresses in the native anatomical components and prosthetic implant with the presence and distribution of relevant calcifications. This alteration is dependent on the patient-specific features of the calcific aortic stenosis and may be a relevant indicator of suboptimal TAVI results.
1 April 2012 in Journal of Biomechanics
6 January 2012 in European Journal of Cardio-Thoracic Surgery
GFGianfranco Beniamino Fiore
Gianfranco Beniamino Fiore
+2
In aortic valve repair, reduction and stabilization of the ventriculo-aortic junction (VAJ) is generally recommended. In this in vitro study, we compare three techniques of annuloplasty: the subcommissural annuloplasty (SCA), the internal ring (IR) and the external ring (ER) annuloplasty. Ten fresh porcine aortic valve preparations were tested in a pulsatile mock loop. Each sample was tested untreated (baseline: B). The annuloplasty techniques were then performed successively in each sample. Each technique was tested, then removed and the following technique performed. SCA was applied at 50% of interleaflet triangle height; the ER and IR were applied with a moderate reduction (15–20%) of the VAJ. Hydrodynamic, video and echographic parameters were collected. Flow rate and arterial pressure were maintained consistently between groups. Effective orifice area decreased significantly with each annuloplasty technique compared with baseline (P < 0.001). Mean transvalvular pressure drop was significantly higher in the ER and IR vs SCA (P = 0.007). Annuloplasty reduced valve opening and closing time in comparison to baseline. Echocardiography confirmed that the VAJ experienced a greater reduction with the ER and IR vs SCA. A narrowing of the lower third of the sinuses of Valsalva was observed after the ER, and subvalvular narrowing was observed after the IR. Valve coaptation increased with all annuloplasty techniques. The three annuloplasty techniques examined demonstrated differential effects on aortic valve function and root morphology. The ER and IR have greater potential to reduce VAJ diameter in comparison to SCA. The IR induced a subvalvular remodelling of the VAJ, whereas the ER induced a paravalvular remodelling.
7 February 2015 in Medical Engineering & Physics
Integration of biological samples into in vitro mock loops is fundamental to simulate real device's operating conditions. We developed an in vitro platform capable of simulating the pumping function of the heart through the external pressurization of the ventricle. The system consists of a fluid-filled chamber, in which the ventricles are housed and sealed to exclude the atria from external loads. The chamber is connected to a pump that drives the motion of the ventricular walls. The aorta is connected to a systemic impedance simulator, and the left atrium to an adjustable preload. The platform reproduced physiologic hemodynamics, i.e. aortic pressures of 120/80 mmHg with 5 L/min of cardiac output, and allowed for intracardiac endoscopy. A pilot study with a left ventricular assist device (LVAD) was also performed. The LVAD was connected to the heart to investigate aortic valve functioning at different levels of support. Results were consistent with the literature, and high speed video recordings of the aortic valve allowed for the visualization of the transition between a fully opening valve and a permanently closed configuration. In conclusion, the system showed to be an effective tool for the hemodynamic assessment of devices, the simulation of surgical or transcatheter procedures and for visualization studies.
15 December 2009 in Artificial Organs