Fuat Akpinar

Fuat Akpinar

Auto-generated profile, based on publicly available information

Fuat Akpinar

Department of Orthopaedics and Traumatology, Istanbul Medeniyet University, Göztepe Prof. Dr. Süleyman Yalçın City Hospital, Istanbul, Türkiye

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2003 in Acta Orthopaedica
Verified
Journal Article
Open access
FAFuat Akpınar
Fuat Akpınar
AAAtıf Aydınlıoglu
Atıf Aydınlıoglu
NTNihat Tosun
Nihat Tosun
ÍTÍbrahim Tuncay
Íbrahim Tuncay
Intramedullary ulnar nailing may be technically difficult. We used various methods and measurements to determine the ideal nail entry point and the shape, length, diameter and curvature of the medullary canal in 44 human cadaver ulnas. We found that the ideal nail entry point was, on average, 7 mm proximal and 3 mm lateral to the most prominent area of the olecranon. A nail of 3 mm diameter could easily be inserted through a hole at the proximal-lateral side of the most prominent part of the olecranon, but only 20% of all nails could be easily inserted through a hole in the middle of the olecranon. We found that correct selection of a nail of proper length and diameter, as well as an ideal nail entry point on the olecranon are essential to successful nailing.

22 June 2006 in Clinical Anatomy
Verified
Journal Article
Closed access
PDF file
ADAli Dogan
Ali Dogan
MUMustafa Uslu
Mustafa Uslu
AAAtif Aydinlioglu
Atif Aydinlioglu
MHMustafa Harman
Mustafa Harman
FAFuat Akpinar
Fuat Akpinar

6 January 2019 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
TETunay Erden
Tunay Erden
MKMehmet Kapicioglu
Mehmet Kapicioglu
ADAbdullah Demirtas
Abdullah Demirtas
KBKerem Bilsel
Kerem Bilsel
FAFuat Akpinar
Fuat Akpinar
HKHacer Kuduz
Hacer Kuduz
Objective: The aim of this study was to compare the biomechanical resistance to rotational and axial forces of a conventional locking nail with a newly designed intramedullary humeral nail developed for humeral shaft fractures with a secure locking mechanism through the distal part of the nail. Methods: InSafeLOCK humeral nail system (group 1, TST, Istanbul, Turkey) and Expert humeral nail system (group 2, DePuy Synthes, Bettlach, Switzerland) of the same size (9 300 mm) were examined. In total, 24 fourth-generation humerus sawbones were used in the experiment. Osteotomy was performed at the humerus shaft, and a defect was created by removing 1 cm of bone. After pre-loading 5000 cycles at a frequency of 2 Hz and a force of 50e250 N for axial loading and 5000 torsion torques between 0.5 Nm and 6.5 Nm at a 2 Hz frequency for torsional loading, the failure load values of each load were recorded. Distal interlocking was performed with an endopin in group 1, while a double cortex screw was used in group 2. Results: All samples successfully passed the cyclic loading. The initial and final stiffness values were similar between the groups after axial loading (p ¼ 0.873 and p ¼ 0.522, respectively). The mean axial failure load values in groups 1 and 2 were 2627 ± 164 N and 7141 ± 1491 N, respectively. A significant difference was found in the axial failure load values (p ¼ 0.004). Significant differences were observed between the initial and final torsional stiffness between the two groups (p ¼ 0.004 and p ¼ 0.004, respectively). No significant difference was found in the failure load values after torsional loading (11791 ± 2055 N.mm and 16997 ± 5440 N.mm) (p ¼ 0.055). Conclusion: These results provide a biomechanical demonstration of the adequate stability of both nails after axial and rotational loading. The reliability of the newly developed InSafeLOCK humeral nail system, which does not require fluoroscopic control and an additional incision for distal locking, supports its use in the clinic.

27 December 2013 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
GSGursel Saka
Gursel Saka
NSNecdet Saglam
Necdet Saglam
TKTuhan Kurtulmus
Tuhan Kurtulmus
UBUgur Bakir
Ugur Bakir
CACem Coskun Avci
Cem Coskun Avci
AAAkgun Alsaran
Akgun Alsaran

1 March 2023 in Journal of Orthopaedic Science
Verified
Journal Article
Closed access
EOErhan Okay
Erhan Okay
KUKadir Ulu
Kadir Ulu
FDFerhat Demir
Ferhat Demir
TSTarık Sari
Tarık Sari
SISamir Ilgaroğlu
Samir Ilgaroğlu
KOKorhan Ozkan
Korhan Ozkan

1 January 2012 in Turkish Journal of Trauma and Emergency Surgery
Verified
Journal Article
Closed access
FKFatih Kucukdurmaz
Fatih Kucukdurmaz
FAFuat Akpinar
Fuat Akpinar
GSGursel Saka
Gursel Saka
NSNecdet Saglam
Necdet Saglam
CACihan Aci
Cihan Aci
The surgical treatment of fractures of the tibia includes reamed and unreamed options. Reamed nails have mechanical advantages but they significantly harm the endosteal circulation. Unreamed nails spare the endosteal circulation, but provide a less stable fixation. In both systems, immediate full weight-bearing is not possible due to instability related to distal interlocking (DI). Further, DI is responsible for the majority of the fluoroscopy requirement and a significant loss of surgical time. In our study, we present the clinical results of a new intramedullary (IM) nail and system, which allows stable fixation with an unreamed technique that permits immediate full weight-bearing, with a minimum fluoroscopy requirement for DI. Fifty tibia fractures (49 patients) operated using our new IM system between 2008 and 2010 were evaluated retrospectively. They were allowed full weight-bearing the day after surgery. The patients were followed at least 10 months postoperatively. Mean fluoroscopy time was 18 seconds (min: 10, max: 30) for DI. Mean union time was 9 weeks (min: 6, max: 12). There was no neurovascular injury, deep infection, malunion, delayed union, or nonunion. We demonstrated that our newly developed IM nail and new DI system may be an option to solve the stability problems sourced from the DI screw. It also significantly decreases the requirement of fluoroscopy.