Wolfgang Wuest

Wolfgang Wuest

Auto-generated profile, based on publicly available information

Wolfgang Wuest

Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2016 in European Radiology
Verified
Journal Article
Closed access
PDF file
WWWolfgang Wuest
Wolfgang Wuest
MMMatthias May
Matthias May
MSMarc Saake
Marc Saake
MBMichael Brand
Michael Brand
MUMichael Uder
Michael Uder
MLMichael Lell
Michael Lell

16 January 2017 in Neuroradiology
Verified
Journal Article
Closed access
PDF file
MMMatthias S May
Matthias S May
MBMichael Brand
Michael Brand
MLMichael M Lell
Michael M Lell
MSMartin Sedlmair
Martin Sedlmair
TAThomas Allmendinger
Thomas Allmendinger
WWWolfgang Wuest
Wolfgang Wuest

13 August 2015 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
WWW. Wuest
W. Wuest
MMM.S. May
M.S. May
MBM. Brand
M. Brand
NBN. Bayerl
N. Bayerl
AKA. Krauss
A. Krauss
MLM. Lell
M. Lell
BACKGROUND AND PURPOSE: Metal artifacts from dental fillings and other devices degrade image quality and may compromise the detection and evaluation of lesions in the oral cavity and oropharynx by CT. The aim of this study was to evaluate the effect of iterative metal artifact reduction on CT of the oral cavity and oropharynx. MATERIALS AND METHODS: Data from 50 consecutive patients with metal artifacts from dental hardware were reconstructed with standard filtered back-projection, linear interpolation metal artifact reduction (LIMAR), and iterative metal artifact reduction. The image quality of sections that contained metal was analyzed for the severity of artifacts and diagnostic value. RESULTS: A total of 455 sections (mean ± standard deviation, 9.1 ± 4.1 sections per patient) contained metal and were evaluated with each reconstruction method. Sections without metal were not affected by the algorithms and demonstrated image quality identical to each other. Of these sections, 38% were considered nondiagnostic with filtered back-projection, 31% with LIMAR, and only 7% with iterative metal artifact reduction. Thirty-three percent of the sections had poor image quality with filtered back-projection, 46% with LIMAR, and 10% with iterative metal artifact reduction. Thirteen percent of the sections with filtered back-projection, 17% with LIMAR, and 22% with iterative metal artifact reduction were of moderate image quality, 16% of the sections with filtered back-projection, 5% with LIMAR, and 30% with iterative metal artifact reduction were of good image quality, and 1% of the sections with LIMAR and 31% with iterative metal artifact reduction were of excellent image quality. CONCLUSIONS: Iterative metal artifact reduction yields the highest image quality in comparison with filtered back-projection and linear interpolation metal artifact reduction in patients with metal hardware in the head and neck area.

18 October 2018 in European Radiology
Verified
Journal Article
Closed access
PDF file
MMMatthias Stefan May
Matthias Stefan May
MWMarco Wiesmueller
Marco Wiesmueller
RHRafael Heiss
Rafael Heiss
MBMichael Brand
Michael Brand
JBJoscha Bruegel
Joscha Bruegel
WWWolfgang Wuest
Wolfgang Wuest

1 September 2018
Verified
Journal Article
Closed access
RHRafael Heiss
Rafael Heiss
THThilo Hotfiel
Thilo Hotfiel
MKMarion Kellermann
Marion Kellermann
Matthias MayMatthias May
Matthias May
WWWolfgang Wuest
Wolfgang Wuest
MHMatthias Hammon
Matthias Hammon

28 November 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
JKJonas Kiefer
Jonas Kiefer
MKMarkus Kopp
Markus Kopp
TRTheresa Ruettinger
Theresa Ruettinger
RHRafael Heiss
Rafael Heiss
WWWolfgang Wuest
Wolfgang Wuest
Matthias MayMatthias May
Matthias May
Intracranial hemorrhages require an immediate diagnosis to optimize patient management and outcomes, and CT is the modality of choice in the emergency setting. We aimed to evaluate the performance of the first scanner-integrated artificial intelligence algorithm to detect brain hemorrhages in a routine clinical setting. This retrospective study includes 435 consecutive non-contrast head CT scans. Automatic brain hemorrhage detection was calculated as a separate reconstruction job in all cases. The radiological report (RR) was always conducted by a radiology resident and finalized by a senior radiologist. Additionally, a team of two radiologists reviewed the datasets retrospectively, taking additional information like the clinical record, course, and final diagnosis into account. This consensus reading served as a reference. Statistics were carried out for diagnostic accuracy. Brain hemorrhage detection was executed successfully in 432/435 (99%) of patient cases. The AI algorithm and reference standard were consistent in 392 (90.7%) cases. One false-negative case was identified within the 52 positive cases. However, 39 positive detections turned out to be false positives. The diagnostic performance was calculated as a sensitivity of 98.1%, specificity of 89.7%, positive predictive value of 56.7%, and negative predictive value (NPV) of 99.7%. The execution of scanner-integrated AI detection of brain hemorrhages is feasible and robust. The diagnostic accuracy has a high specificity and a very high negative predictive value and sensitivity. However, many false-positive findings resulted in a relatively moderate positive predictive value.