Michael Lell

Michael Lell

Auto-generated profile, based on publicly available information

Michael Lell

Klinikum Nürnberg

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2023 in Investigative Radiology
Verified
Journal Article
Open access
MLMichael Lell
Michael Lell
MKMarc Kachelrieß
Marc Kachelrieß
Computed tomography (CT) dramatically improved the capabilities of diagnostic and interventional radiology. Starting in the early 1970s, this imaging modality is still evolving, although tremendous improvements in scan speed, volume coverage, spatial and soft tissue resolution, as well as dose reduction have been achieved. Tube current modulation, automated exposure control, anatomy-based tube voltage (kV) selection, advanced x-ray beam filtration, and iterative image reconstruction techniques improved image quality and decreased radiation exposure. Cardiac imaging triggered the demand for high temporal resolution, volume acquisition, and high pitch modes with electrocardiogram synchronization. Plaque imaging in cardiac CT as well as lung and bone imaging demand for high spatial resolution. Today, we see a transition of photon-counting detectors from experimental and research prototype setups into commercially available systems integrated in patient care. Moreover, with respect to CT technology and CT image formation, artificial intelligence is increasingly used in patient positioning, protocol adjustment, and image reconstruction, but also in image preprocessing or postprocessing. The aim of this article is to give an overview of the technical specifications of up-to-date available whole-body and dedicated CT systems, as well as hardware and software innovations for CT systems in the near future.

13 August 2015 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
WWW. Wuest
W. Wuest
MMM.S. May
M.S. May
MBM. Brand
M. Brand
NBN. Bayerl
N. Bayerl
AKA. Krauss
A. Krauss
MLM. Lell
M. Lell
BACKGROUND AND PURPOSE: Metal artifacts from dental fillings and other devices degrade image quality and may compromise the detection and evaluation of lesions in the oral cavity and oropharynx by CT. The aim of this study was to evaluate the effect of iterative metal artifact reduction on CT of the oral cavity and oropharynx. MATERIALS AND METHODS: Data from 50 consecutive patients with metal artifacts from dental hardware were reconstructed with standard filtered back-projection, linear interpolation metal artifact reduction (LIMAR), and iterative metal artifact reduction. The image quality of sections that contained metal was analyzed for the severity of artifacts and diagnostic value. RESULTS: A total of 455 sections (mean ± standard deviation, 9.1 ± 4.1 sections per patient) contained metal and were evaluated with each reconstruction method. Sections without metal were not affected by the algorithms and demonstrated image quality identical to each other. Of these sections, 38% were considered nondiagnostic with filtered back-projection, 31% with LIMAR, and only 7% with iterative metal artifact reduction. Thirty-three percent of the sections had poor image quality with filtered back-projection, 46% with LIMAR, and 10% with iterative metal artifact reduction. Thirteen percent of the sections with filtered back-projection, 17% with LIMAR, and 22% with iterative metal artifact reduction were of moderate image quality, 16% of the sections with filtered back-projection, 5% with LIMAR, and 30% with iterative metal artifact reduction were of good image quality, and 1% of the sections with LIMAR and 31% with iterative metal artifact reduction were of excellent image quality. CONCLUSIONS: Iterative metal artifact reduction yields the highest image quality in comparison with filtered back-projection and linear interpolation metal artifact reduction in patients with metal hardware in the head and neck area.

1 October 2016 in Academic Radiology
Verified
Journal Article
Closed access
FSFrank Schaller
Frank Schaller
MSMartin Sedlmair
Martin Sedlmair
RRRainer Raupach
Rainer Raupach
MUMichael Uder
Michael Uder
MLMichael Lell
Michael Lell

20 March 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MLMichael M. Lell
Michael M. Lell
UFUlrike Fleischmann
Ulrike Fleischmann
HPHubertus Pietsch
Hubertus Pietsch
JKJohannes G. Korporaal
Johannes G. Korporaal
UHUlrike Haberland
Ulrike Haberland
GJGregor Jost
Gregor Jost
Very short acquisition times and the use of low-kV protocols in CTA demand modifications in the contrast media (CM) injection regimen. The aim of this study was to optimize the use of CM delivery parameters in thoraco-abdominal CTA in a porcine model. Six pigs (55–68 kg) were examined with a dynamic CTA protocol (454 mm scan length, 2.5 s temporal resolution, 70 s total acquisition time). Four CM injection protocols were applied in a randomized order. 120 kV CTA protocol: (A) 300 mg iodine/kg bodyweight (bw), IDR = 1.5 g/s (flow = 5 mL/s), injection time (ti) 12 s (60 kg bw). 70 kV CTA protocols: 150 mg iodine/kg bw: (B) IDR = 0.75 g/s (flow = 2.5 mL/s), ti = 12 s (60 kg bw); (C) IDR = 1.5 g/s (flow = 5 mL/s), ti = 12 s (60 kg bw); (D) IDR = 3.0 g/s (flow = 10 mL/s), ti = 3 s (60 kg bw). The complete CM bolus shape was monitored by creating time attenuation curves (TAC) in different vascular territories. Based on the TAC, the time to peak (TTP) and the peak enhancement were determined. The diagnostic window (relative enhancement > 300 HU), was calculated and compared to visual inspection of the corresponding CTA data sets. The average relative arterial peak enhancements after baseline correction were 358.6 HU (A), 356.6 HU (B), 464.0 HU (C), and 477.6 HU (D). The TTP decreased with increasing IDR and decreasing ti, protocols A and B did not differ significantly (systemic arteries, p = 0.843; pulmonary arteries, p = 0.183). The delay time for bolus tracking (trigger level 100 HU; target enhancement 300 HU) for single-phase CTA was comparable for protocol A and B (3.9, 4.3 s) and C and D (2.4, 2.0 s). The scan window time frame was comparable for the different protocols by visual inspection of the different CTA data sets and by analyzing the TAC. All protocols provided sufficient arterial enhancement. The use of a 70 kV CTA protocol is recommended because of a 50% reduction of total CM volume and a 50% reduced flow rate while maintaining the bolus profile. In contrast to pulmonary arterial enhancement, the systemic arterial enhancement improved only slightly increasing the IDR from 1.5 g/s to 3 g/s because of bolus dispersion of the very short bolus (3s) in the lungs.

22 June 2004 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
RSR. Schulz-Wendtland
R. Schulz-Wendtland
KHK.-P. Hermann
K.-P. Hermann
MLM. Lell
M. Lell
CBC. Böhner
C. Böhner
EWE. Wenkel
E. Wenkel
WBW. Bautz
W. Bautz
Ziel: Experimentelle Phantomstudie zur Detektion simulierter Läsionen an fünf verschiedenen digitalen und einem konventionellen Mammographiesystem. Material und Methoden: Es wurden je 3 Phantomaufnahmen bei unterschiedlicher Phantomkonfiguration mit einem konventionellen Film-Folien-System (Mammomat 3000 N, Fa. Siemens) und 5 digitalen Mammographie-Systemen (hochauflösendes Speicherfoliensystem, Fa. Fuji/Siemens; a-Si Detektor, Fa. GE Medical Systems; a-Se Detektoren, Fa. Siemens, Fa. Hologic/Lorad; und CCD-Detektor, Fa. Fischer Imaging) bei gleichen Aufnahmeparametern angefertigt. Testobjekt war das Wisconsin-Mammographic-Random-Phantom, Modell 152 A. Fünf Untersuchern mit unterschiedlicher Mammographieerfahrung (3 Monate bis mehr als 4 Jahre) wurden die 18 Aufnahmen in willkürlicher Reihenfolge (Zufallsgenerator) zur Auswertung vorgelegt. Ergebnisse: Es ergaben sich für die konventionelle Film-Folien-Mammographie (84,9 %), die hochauflösende Speicherfolientechnik (86,7 %) und die digitale Mammographie mit a-Si-Detektor (89,8 %) keine signifikanten Unterschiede bezüglich der Detektion der simulierten Mammaläsionen. Die digitalen a-Se-Systeme (97,3 %) und das CCD-System (100 %) erreichten hochsignifikant bessere Detektionsraten (p < 0,001). Schlussfolgerung: Die konventionelle Film-Folien-Mammographie kann durch die digitale Mammographie mit hochauflösenden Speicherfolien und durch die digitale Mammographie mit a-Si-, a-Se- und CCD-Detektoren ersetzt werden - dies müssen jedoch weitere klinische Studien zeigen. Purpose: Experimental phantom study for the detection of simulated lesions with five different digital and one conventional screen-film mammography system. Materials and Methods: Three radiographs were obtained at various configurations of the phantom with one conventional screen-film system (Mammomat 3000 N) (Siemens), five digital systems (high resolution computed radiography system [Fuji/Siemens], one a-Si detector [GE Medical Systems], two a-Se detectors [Siemens; Hologic / Lorad] and one CCD detector [Fischer Imaging]), applying the same exposure parameters. The Wisconsin Mammographic Random Phantom, Model 152 A, was used. Five investigators with different experience in mammography (3 months to more than 4 years) evaluated the 18 randomly selected radiographs. Results: No significant differences were found in the detection rate of simulated breast lesions for conventional screen-film mammography (84.9 %), high resolution computed radiography (86.7 %) and digital mammography with an a-Si detector (89.8 %). Highly significantly better results (p < 0.001) were found with the two a-Se systems (97.3 %) and the CCD system (100 %). Conclusion: Conventional screen-film mammography can be replaced by high resolution computed radiography and digital mammography with a-Si-, a-Se- and CCD-detectors. This has to be confirmed in further clinical studies.

13 May 2021 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
EGEwald Guni
Ewald Guni
IHIngo Hellmann
Ingo Hellmann
MWMichael Wucherer
Michael Wucherer
PKPetra Knappe-Kagan
Petra Knappe-Kagan
JHJosefin Hartmann
Josefin Hartmann
RARalf Adamus
Ralf Adamus