Yu. A. Pustov

Yu. A. Pustov

Auto-generated profile, based on publicly available information

Yu. A. Pustov

Department of Steel Metallurgy, New Production Technologies and Protection of Metals, National University of Science and Technology “MISiS”, 119049 Moscow, Russia

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
SPSergey Prokoshkin
Sergey Prokoshkin
YPYury Pustov
Yury Pustov
YZYulia Zhukova
Yulia Zhukova
PKPulat Kadirov
Pulat Kadirov
MKMaria Karavaeva
Maria Karavaeva
SDSergey Dubinskiy
Sergey Dubinskiy
The Fe-Mn-Si shape memory alloys are considered promising materials for the biodegradable bone implant application since their functional properties can be optimized to combine bioresorbability with biomechanical and biochemical compatibility with bone tissue. The present study focuses on the fatigue and corrosion fatigue behavior of the thermomechanically treated Fe-30Mn-5Si (wt %) alloy compared to the conventionally quenched alloy because this important functionality aspect has not been previously studied. Hot-rolled and water-cooled, cold-rolled and annealed, and conventionally quenched alloy samples were characterized by X-ray diffraction, transmission electron microscopy, tensile fatigue testing in air atmosphere, and bending corrosion fatigue testing in Hanks’ solution. It is shown that hot rolling at 800 °C results in the longest fatigue life of the alloy both in air and in Hanks’ solution. This advantage results from the formation of a dynamically recrystallized γ-phase grain structure with a well-developed dislocation substructure. Another important finding is the experimental verification of Young’s modulus anomalous temperature dependence for the studied alloy system, its minimum at a human body temperature, and corresponding improvement of the biomechanical compatibility. The idea was realized by lowering Ms temperature down to the body temperature after hot rolling at 800 °C.

1 May 2018 in Protection of Metals and Physical Chemistry of Surfaces
Verified
Journal Article
Closed access
PDF file
YPYu. A. Pustov
Yu. A. Pustov
YZYulia Zhukova
Yulia Zhukova
PMP. E. Malikova
P. E. Malikova
SPS. D. Prokoshkin
S. D. Prokoshkin
SDS. M. Dubinskii
S. M. Dubinskii
The structural state under varied conditions of thermal and thermomechanical treatment, the possibility of realization of a reversible martensitic transformation, and electrochemical behavior and...

24 May 2012 in Protection of Metals and Physical Chemistry of Surfaces
Verified
Journal Article
Closed access
PDF file
YZYulia Zhukova
Yulia Zhukova
YPYu. A. Pustov
Yu. A. Pustov
MFM. R. Filonov
M. R. Filonov
Chronopotentiometry and potentiodynamic voltammetry simulated were used to study the electrochemical behavior of the new pseudoelastic medical Ti-Nb-Ta alloy in simulated physiological media (neutral and acidified Hank’s solution, artificial saliva) at temperatures of 37 and 50°C as compared to titanium and nitinol. The mechanism of formation of protective passive films on the alloy surface is proposed on the basis of analysis of kinetic regularities used to establish steady-state potentials during exposure to the corresponding solutions. X-ray photoelectron spectroscopy technique was used to study the composition of passivating layers on the surface of the Ti-Nb-Ta alloy after corrosion tests. It is found that the new alloy is as good as titanium as regards its corrosion-electrochemical characteristics and is not subjected to pitting corrosion, as opposed to nitinol.

29 July 2014 in Protection of Metals and Physical Chemistry of Surfaces
Verified
Journal Article
Closed access
PDF file
YPYu. A. Pustov
Yu. A. Pustov
YZYulia Zhukova
Yulia Zhukova
MFM. R. Filonov
M. R. Filonov
The effect of cyclic dynamic loading on the kinetics of changes in the electrode potentials of Ti-22Nb-6Ta and Ti-22Nb-6Zr (at %) superelastic medical alloys in a model solution simulating the bone tissue environment in a living organism is studied with the use of electrochemical chronopotentiometry. An increase in the applied load from 450 to 780 MPa is found to affect dramatically the character of changes in the electrode potentials of the alloys during exposure. Ti-22Nb-6Ta alloy exhibits higher resistance to corrosion fatigue cracking than does Ti-22Nb-6Zr alloy. It is shown that the superelasticity of the alloys is responsible for the deceleration of the corrosion fatigue cracking due to the blocking effect of martensite crystals formed in the structure during the loading half-cycle, which is confirmed by the low rate of the potential decrease after the nucleation of corrosion fatigue cracks.

24 May 2014 in Journal of Materials Engineering and Performance
Verified
Journal Article
Closed access
PDF file
YZYulia Zhukova
Yulia Zhukova
YPYu. A. Pustov
Yu. A. Pustov
AKAnton Konopatsky
Anton Konopatsky
MFM. R. Filonov
M. R. Filonov
SPSergey Prokoshkin
Sergey Prokoshkin

27 July 2019 in Materials
Verified
Journal Article
Open access
PDF file
YZYulia Zhukova
Yulia Zhukova
AKAnastasia Korobkova
Anastasia Korobkova
SDSergey Dubinskiy
Sergey Dubinskiy
YPYury Pustov
Yury Pustov
AKAnton Konopatsky
Anton Konopatsky
VBVladimir Brailovski
Vladimir Brailovski
Titanium alloys are well recognized as appropriate materials for biomedical implants. These devices are designed to operate in quite aggressive human body media, so it is important to study the corrosion and electrochemical behavior of the novel materials alongside the underlying chemical and structural features. In the present study, the prospective Ti‒Zr-based superelastic alloys (Ti-18Zr-14Nb, Ti-18Zr-15Nb, Ti-18Zr-13Nb-1Ta, atom %) were analyzed in terms of their phase composition, functional mechanical properties, the composition and structure of surface oxide films, and the corresponding corrosion and electrochemical behavior in Hanks’ simulated biological solution. The electrochemical parameters of the Ti-18Zr-14Nb material in bulk and foam states were also compared. The results show a significant difference in the functional performance of the studied materials, with different composition and structure states. In particular, the positive effect of the thermomechanical treatment regime, leading to the formation of a favorable microstructure on the corrosion resistance, has been revealed. In general, the Ti-18Zr-15Nb alloy exhibits the optimum combination of functional characteristics in Hanks’ solution, while the Ti-18Zr-13Nb-1Ta alloy shows the highest resistance to the corrosion environment. The Ti-18Zr-14Nb-based foam material exhibits slightly lower passivation kinetics as compared to its bulk equivalent.