1 December 2020 in Electric Power Systems Research
HSH.M. Jeewantha De Silva
21 May 2020 in IET Generation, Transmission & Distribution
Grounding electrodes have an important role in electric power transmission and distribution systems. They are used to prevent excessive hazardous voltages due to ground potential rise in the case of system faults or lightning surges. The electrical properties of soil, which vary substantially with geographical location and time of year, affect the process considerably along with the properties of the grounding electrode itself, such as its dimensions. To have an accurate estimation of the induced overvoltages due to lightning strike, one has to take into account the effect of the value of the soil electrical parameters, such as the electrical conductivity and dielectric constant. This study investigates the high frequency behaviour of the grounding electrodes by solving a full‐wave electromagnetic problem using the finite element method. The focus of this paper is on the effect of the variation of soil relative permittivity on the induced transient voltage in grounding electrodes. This allows an evaluation of the response of grounding systems due to seasonal changes, which would cause its electrical properties to vary significantly. This study demonstrates the importance of considering the variation of relative permittivity of the soil especially in the modelling of electrodes buried in highly resistive soil.
1 September 2021 in Electric Power Systems Research
17 June 2020 in IEEE Transactions on Power Delivery
When lightning strikes a transmission line tower or shield wires, electromagnetic waves propagate through the tower back and forth, increasing the voltage across insulator strings. To calculate the over-voltages, an accurate model of the tower and its grounding system is needed in electromagnetic transient (EMT) type simulators. There are a number of theoretical models for the equivalent circuit of a tower. However, they either are not accurate enough or they are derived for a certain type of transmission tower, which limits their applicability. Numerical electromagnetic analyses have less simplifications compared to the theoretical solutions and are less expensive than field measurements. In this paper, the direct method for the measurement of tower impedance is implemented by NEC4 and applied to a 400-kV double circuit tower. The process of obtaining the wire network of the tower used in this paper is completely automated and it can be applied to any other type of transmission tower. The results of the numerical simulations are compared to those obtained with existing tower models. The developed model is capable of considering all the details of the tower and including the finite resistance of the ground and grounding electrodes.
1 October 2021 in Electric Power Systems Research