William D. Blincoe

William D. Blincoe

Auto-generated profile, based on publicly available information

William D. Blincoe

Process Analytical Technology, MMD, Merck & Co., Inc., West Point, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2018 in Science
Verified
Journal Article
Closed access
PDF file
SLShishi Lin
Shishi Lin
SDSergei Dikler
Sergei Dikler
WBWilliam D. Blincoe
William D. Blincoe
RFRonald D. Ferguson
Ronald D. Ferguson
RSRobert P. Sheridan
Robert P. Sheridan
SDSpencer D. Dreher
Spencer D. Dreher
A rapid screen for complex reactants: Chemists engaged in reaction discovery tend to report outcomes involving a few, relatively simple reactants. It remains a major challenge to fine-tune reported conditions when the reactants become more structurally complex, as often happens in pharmaceutical research. Lin et al. developed a protocol for rapidly screening different catalytic conditions for C–N coupling across a wide range of complex substrates. The product detection scheme relies on mass spectrometry of nanomole-scale reaction mixtures without any need for intervening chromatography. Science , this issue p. eaar6236

2 August 2024 in The AAPS Journal
Verified
Journal Article
Open access
PDF file
MLMichel Louge
Michel Louge
JMJasdeep Mandur
Jasdeep Mandur
PGPlamen Grigorov
Plamen Grigorov
WBWilliam Blincoe
William Blincoe
DLDavid Lamberto
David Lamberto
RMRobert F. Meyer
Robert F. Meyer
A non-invasive capacitance instrument was embedded in the base of a vacuum-drying tray to monitor continuously the residual amount of solvent left in a pharmaceutical powder. Proof of concept was validated with Microcrystalline Cellulose laced with water, as well as water/acetone mixtures absorbed in a spray-dried Copovidone powder. To illustrate the role of impermeability of the base, we derive a model of vapor sorption that reveals the existence of a kinetic limit when solids are thinly spread, and a diffusion limit with greatly diminished effective diffusivity at large powder thickness. By monitoring the residual solvent content of powders, this new in situ technique offers advantages over indirect methods like mass spectrometry of vapor effluents, but without complications associated with probe fouling. To prescribe design guidelines and interpret signals, we model the electric field shed by the probe when a powder holds variable solvent mass fraction in the vertical direction. Graphical