Linnea Jarenbäck

Linnea Jarenbäck

Auto-generated profile, based on publicly available information

Linnea Jarenbäck

Department of Clinical Sciences, Lund, Respiratory medicine, allergology and palliative medicine, Lund University, Lund, Sweden

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2014 in Annals of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MBMarika Bajc
Marika Bajc
HMHanna Markstad
Hanna Markstad
LJLinnea Jarenbäck
Linnea Jarenbäck
ETEllen Tufvesson
Ellen Tufvesson
LBLeif Bjermer
Leif Bjermer
JJJonas Jögi
Jonas Jögi
The severity of chronic obstructive lung disease (COPD) is defined by the degree of flow limitation measured as forced expiratory volume in 1 s, which mainly reflects impairment of large and intermediate airways. However, COPD is primarily a small airways disease. Therefore, better diagnostic tools are needed. Ventilation-Perfusion (V/P) SPECT is a sensitive method to detect obstructive lung changes but criteria for staging airway obstruction are missing.

1 January 2013 in Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
LJLinnea Jarenbäck
Linnea Jarenbäck
JAJaro Ankerst
Jaro Ankerst
LBLeif Bjermer
Leif Bjermer
ETEllen Tufvesson
Ellen Tufvesson
Classification of COPD into different GOLD stages is based on forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) but has shown to be of limited value. The aim of the study was to relate spirometry values to more advanced measures of lung function in COPD patients compared to healthy smokers. The lung function of 65 COPD patients and 34 healthy smokers was investigated using flow-volume spirometry, body plethysmography, single breath helium dilution with CO-diffusion, and impulse oscillometry. All lung function parameters, measured by body plethysmography, CO-diffusion, and impulse oscillometry, were increasingly affected through increasing GOLD stage but did not correlate with FEV1within any GOLD stage. In contrast, they correlated fairly well with FVC%p, FEV1/FVC, and inspiratory capacity. Residual volume (RV) measured by body plethysmography increased through GOLD stages, while RV measured by helium dilution decreased. The difference between these RV provided valuable additional information and correlated with most other lung function parameters measured by body plethysmography and CO-diffusion. Airway resistance measured by body plethysmography and impulse oscillometry correlated within COPD stages. Different lung function parameters are of importance in COPD, and a thorough patient characterization is important to understand the disease.

11 November 2015 in Respiratory Medicine
Verified
Journal Article
Open access
PDF file
LJLinnea Jarenbäck
Linnea Jarenbäck
JAJaro Ankerst
Jaro Ankerst
LBLeif Bjermer
Leif Bjermer
ETEllen Tufvesson
Ellen Tufvesson
• Acinar ventilation heterogeneity is increased with increasing COPD degree. • Ventilation heterogeneity in conductive airways was not affected in COPD. • Sacin in COPD is strongly related to diffusion capacity. • Sacin in COPD is associated with airway resistance and reactance measured by IOS.

1 November 2016 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
LJLinnea Jarenbäck
Linnea Jarenbäck
GEGöran Eriksson
Göran Eriksson
SPStefan Peterson
Stefan Peterson
JAJaro Ankerst
Jaro Ankerst
LBLeif Bjermer
Leif Bjermer
ETEllen Tufvesson
Ellen Tufvesson
Background: COPD is defined as partly irreversible airflow obstruction. The response pattern of bronchodilators has not been followed in advanced lung function parameters. Purpose: The aim of this study was to investigate bronchodilator response pattern in advanced lung function parameters in a continuous fashion along forced expiratory volume in 1 second (FEV1) percent predicted (%p) in COPD patients and controls. Patients and methods: Eighty-one smokers/ex-smokers (41 controls and 40 COPD) performed spirometry, body plethysmography, impulse oscillometry and single-breath helium dilution carbon monoxide diffusion at baseline, after salbutamol inhalation and then after an additional inhalation of ipratropium. Results: Most pulmonary function parameters showed a linear increase in response to decreased FEV1%p. The subjects were divided into groups of FEV1%p 65, and the findings from continuous analysis were verified. The exceptions to this linear response were inspiratory capacity (IC), forced vital capacity (FVC), FEV1/FVC and expiratory resistance (Rex), which showed a segmented response relationship to FEV1%p. IC and FVC, with break points (BP) of 57 and 58 FEV1%p respectively, showed no response above, but an incresed slope below the BP. In addition, in patients with FEV1%p 65, response of FEV1%p did not correlate to response of volume parameters. Conclusion: Response of several advanced lung function parameters differs depending on patients’ baseline FEV1%p, and specifically response of volume parameters is most pronounced in COPD patients with FEV1%p <65. Volume and resistance responses do not follow the flow response measured with FEV1 and may thus be used as a complement to FEV1 reversibility to identify flow, volume and resistance responders.

1 October 2015 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
GEGoran Eriksson
Goran Eriksson
LJLinnea Jarenbäck
Linnea Jarenbäck
SPStefan Peterson
Stefan Peterson
JAJaro Ankerst
Jaro Ankerst
LBLeif Bjermer
Leif Bjermer
ETEllen Tufvesson
Ellen Tufvesson
Purpose: COPD is a progressive disease, which can take different routes, leading to great heterogeneity. The aim of the post-hoc analysis reported here was to perform continuous analyses of advanced lung function measurements, using linear and nonlinear regressions. Patients and methods: Fifty-one COPD patients with mild to very severe disease (Global Initiative for Chronic Obstructive Lung Disease [GOLD] Stages I–IV) and 41 healthy smokers were investigated post-bronchodilation by flow-volume spirometry, body plethysmography, diffusion capacity testing, and impulse oscillometry. The relationship between COPD severity, based on forced expiratory volume in 1 second (FEV1), and different lung function parameters was analyzed by flexible nonparametric method, linear regression, and segmented linear regression with break-points. Results: Most lung function parameters were nonlinear in relation to spirometric severity. Parameters related to volume (residual volume, functional residual capacity, total lung capacity, diffusion capacity [diffusion capacity of the lung for carbon monoxide], diffusion capacity of the lung for carbon monoxide/alveolar volume) and reactance (reactance area and reactance at 5Hz) were segmented with break-points at 60%–70% of FEV1. FEV1/forced vital capacity (FVC) and resonance frequency had break-points around 80% of FEV1, while many resistance parameters had break-points below 40%. The slopes in percent predicted differed; resistance at 5 Hz minus resistance at 20 Hz had a linear slope change of -5.3 per unit FEV1, while residual volume had no slope change above and -3.3 change per unit FEV1 below its break-point of 61%. Conclusion: Continuous analyses of different lung function parameters over the spirometric COPD severity range gave valuable information additional to categorical analyses. Parameters related to volume, diffusion capacity, and reactance showed break-points around 65% of FEV1, indicating that air trapping starts to dominate in moderate COPD (FEV1 =50%–80%). This may have an impact on the patient’s management plan and selection of patients and/or outcomes in clinical research.

21 April 2022 in ERJ Open Research
Verified
Journal Article
Open access
PDF file
LJLinnea Jarenbäck
Linnea Jarenbäck
SFSophia Frantz
Sophia Frantz
JWJulie Weidner
Julie Weidner
JAJaro Ankerst
Jaro Ankerst
UNUlf Nihlén
Ulf Nihlén
ETEllen Tufvesson
Ellen Tufvesson
Single nucleotide polymorphisms (SNPs) in various genes have been shown to associate with COPD, suggesting a role in disease pathogenesis. Sulfatase modifying factor (SUMF1) is a key modifier in connective tissue remodelling, and we have shown previously that several SNPs inSUMF1are associated with COPD. The aim of this study was to investigate the association betweenSUMF1SNPs and advanced lung function characteristics.Never-, former and current smokers with (n=154) or without (n=405) COPD were genotyped for 21 SNPs inSUMF1and underwent spirometry, body plethysmography, diffusing capacity of the lung for carbon monoxide (DLCO) measurement and impulse oscillometry.Four SNPs (rs793391, rs12634248, rs2819590 and rs304092) showed a significantly decreased odds ratio of having COPD when heterozygous for the variance allele, together with a lower forced expiratory volume in 1 s (FEV1) and FEV1/forced vital capacity (FVC) ratio and an impaired peripheral resistance and reactance. Moreover, individuals homozygous for the variance allele of rs3864051 exhibited a strong association to COPD, a lower FEV1/FVC, FEV1andDLCO, and an impaired peripheral resistance and reactance. Other SNPs (rs4685744, rs2819562, rs2819561 and rs11915920) were instead associated with impaired lung volumes and exhibited a lower FVC, total lung capacity and alveolar volume, in individuals having the variance allele.Several SNPs in theSUMF1gene are shown to be associated with COPD and impaired lung function. These genetic variants ofSUMF1may cause a deficient sulfation balance in the extracellular matrix of the lung tissue, thereby contributing to the development of COPD.