Qian Zhang

Qian Zhang

Auto-generated profile, based on publicly available information

Qian Zhang

Laboratory of Applied Research on Electromagnetics (ARE), Zhejiang University, Hangzhou, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2024 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
FPFangyun Peng
Fangyun Peng
QZQian Zhang
Qian Zhang
XLXiaobo Liu
Xiaobo Liu
Zhengpeng WangZhengpeng Wang
Zhengpeng Wang
Xiaoming ChenXiaoming Chen
Xiaoming Chen
A spherical sparse sampling near-field measurements method based on the compressed sensing (CS) approach is proposed in this letter. Since the energy of the spherical wave expansion coefficients (SWECs) of the antenna is concentrated in a limited set of coefficients, sparse optimization sampling becomes a viable choice. To minimize the testing time, non-uniform or adaptive sampling has been extensively explored. However, in practical testing scenarios, these sampling methods fail to guarantee a reduction in the mechanical motion time of the sampling path, making the CS approaches a huge challenge. The proposed uniform undersampling method based on the two-step iterative shrinkage/thresholding (TwIST) algorithm ensures a reduction in sampling time and is suitable for both single-probe and multi-probe sampling systems. A comparison of the near-field to far-field transformation (NFFFT) accuracy between the classical CS methods and the proposed scheme validates its effectiveness. The proposed method achieves a truncation mode number of only one-third of that required by traditional FFT methods at the same error level. Simulation and measurement results verify the feasibility of this method.

31 May 2024 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
QZQian Zhang
Qian Zhang
JWJie Wang
Jie Wang
HYHuilong Yu
Huilong Yu
JLJianpeng Liu
Jianpeng Liu
JWJun Wang
Jun Wang
LRLixin Ran
Lixin Ran
Recently, computational microwave imaging (CMI) based on randomized measurements has been validated effective to achieve low-cost, high-resolution imaging. In this work, we present a CMI system with a phase-reconfigurable transmitarray (PRTA). The main contributions are threefold. First, a low-cost PRTA capable of achieving 1-bit, 0/ $\pi$ phase modulation is realized for optimal imaging with a minimal insertion loss of 0.5 dB. Second, a discrete-dipole approximation model of the PRTA is derived to predict the fields radiated onto the imaging plane. By doing so, the transfer matrix can be quickly established by numerical calculations, eliminating the need of time-consuming calibration measurements, and enabling real-time and flexible experimental imaging with desired imaging distance and resolution. Third, a randomly focused field illumination strategy was used for CMI in this work, reducing the interference reflections from surrounding objects and improving the signal-to-noise ratio (SNR) of measured signals. An experimental prototype working at 24 GHz with a 16 $\times$ 16-element PRTA was realized, showing imaging results that capable of distinguishing two objects separated by 4 mm (about 0.32 $\lambda)$ , indicating a sub-wavelength scale imaging resolution.

27 May 2021 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
QZQian Zhang
Qian Zhang
QXQiangli Xi
Qiangli Xi
CMChao Ma
Chao Ma
BZBin Zhang
Bin Zhang
TZTianyi Zhou
Tianyi Zhou
LRLixin Ran
Lixin Ran
Recently, microwave imaging based on randomized illuminations has demonstrated promising potentials. The key to realize such imaging is to implement an imager with a reconfigurable, randomized aperture. In this work, we discuss the theory and the guidelines for implementing such an imager and demonstrate an experimental prototype working in the 24-GHz ISM band. It is realized with a board-integrated, space-fed, 400-element phased array capable of realizing independent 1-bit phase modulations for each element. The fields transmitting through this aperture can be deterministically randomized by simply controlling direct current bias voltages. Assisted by optimized system calibration and standard $\ell _{1}$ -norm regularization, experimental imaging with a notably improved quality can be obtained. The proposed solution can be used in wide applications, especially suitable for the massive personal security screenings in common public, government, and military areas.

24 September 2024 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
XZXiaoli Zhi
Xiaoli Zhi
KHKe Huang
Ke Huang
QZQian Zhang
Qian Zhang
BZBin Zhang
Bin Zhang
ZZZhongbo Zhu
Zhongbo Zhu
LRLixin Ran
Lixin Ran
In practical applications, a highly flexible conformal phased array will experience inevitable deformations during severe weather conditions. This will distort radiating beams, especially beam directions. To overcome this technical challenge, we propose and experimentally demonstrate a self-adaptive phased array printed on a highly flexible, strongly deformable aperture. The unique novelty of this study is the use of a single six-axis inertial measurement unit (IMU) for each array element to measure the element positions in real time during deformations, and the derivation of a dedicated algorithm integrating accelerations, angular velocities, and phases of elements to compensate for the deterioration of radiating patterns due to deformations. Microwave vector multipliers (VMs) are further used to control the phases continuously. Finally, an experimental prototype operating in S-band is implemented, validating the effectiveness of the proposed approach.

15 February 2023 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
QZQian Zhang
Qian Zhang
QXQiangli Xi
Qiangli Xi
CZChengkai Zhu
Chengkai Zhu
BZBin Zhang
Bin Zhang
JWJie Wang
Jie Wang
LRLixin Ran
Lixin Ran
Microwave imaging under the illumination of randomized fields has demonstrated promising potential. Recent results showed that based on a phase-reconfigurable frequency-selective surface (PFSS), a cost-effective 24-GHz imager can be implemented, showing a wavelength-scale resolution. In this work, we further improve this imager by realizing duplexed random phase modulations. Numerical and experimental results showed that based on the same PFSS, the proposed duplex imager can significantly increase the number of available independent measurements (AIMs) and the sensing capacity. As the result, the error of the reconstructed image can be reduced by 49%, and the imaging resolution reaches 6.25 mm, that is, a half wavelength at 24 GHz. The aperture of the proposed duplex imager can be conveniently extended, exhibiting a promising potential in low-cost security scanning applications, especially for large objects such as human bodies.

10 October 2023 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
YWYuting Wu
Yuting Wu
HMHongbin Ma
Hongbin Ma
YZYinger Zhang
Yinger Zhang
QZQian Zhang
Qian Zhang
ZWZhouyi Wu
Zhouyi Wu
Jiangtao HuangfuJiangtao Huangfu
Jiangtao Huangfu
Based on a reconfigurable spatial dispersive radiation antenna, a microwave compressive sensing imaging method is proposed in this article. According to theoretical analysis, it cannot improve lateral resolution without reducing range resolution in a traditional dispersion-based microwave imaging system. In this work, the issue is addressed by the proposed tunable traveling wave antenna (T-TWA) and variable spatial dispersion compressed sensing (CS) imaging. The T-TWA realizes mechanical, spatial dispersion radiation reconfiguration within the 6.5–10.5 GHz frequency band while maintaining the radiation surface position fixed. Then, the CS algorithm is applied to implement 2-D imaging and positioning on a 5 mm side length target. Simulation and experiment demonstrate that the proposed system attains a lateral resolution of 2 mm (about 1/20 central wavelength) and a range resolution of 7 mm (about 1/5 central wavelength), exhibiting a tenfold and a fivefold enhancement compared to theoretical, respectively. Compared with the imaging system based on a nonadjustable dispersion antenna, the imaging resolution is improved by more than twice in the lateral direction. The proposed imaging system and the tunable dispersive antenna are applicable in fields like vehicle radar, indoor electromagnetic positioning, etc.