Valérie Malfroy Camine

Valérie Malfroy Camine

Auto-generated profile, based on publicly available information

Valérie Malfroy Camine

Laboratory of Biomechanical Orthopedics, Ecole Polytechnique Fédérale de Lausanne, Station 19, 1015 Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2013 in Clinical Biomechanics
Verified
Journal Article
Closed access
PDF file
ATAlexandre Terrier
Alexandre Terrier
XLX. Larrea
X. Larrea
VCV. Malfroy Camine
V. Malfroy Camine
DPDominique Pioletti
Dominique Pioletti
AFA. Farron
A. Farron

1 January 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
MMMohamadreza Nassajian Moghadam
Mohamadreza Nassajian Moghadam
Philippe Abdel-SayedPhilippe Abdel-Sayed
Philippe Abdel-Sayed
VCValérie Malfroy Camine
Valérie Malfroy Camine
DPDominique Pioletti
Dominique Pioletti

1 December 2016 in Journal of Biomechanics
Verified
Journal Article
Closed access
VCV. Malfroy Camine
V. Malfroy Camine
HRH.A. Rüdiger
H.A. Rüdiger
DPD.P. Pioletti
D.P. Pioletti
ATAlexandre Terrier
Alexandre Terrier

4 April 2014 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
CEChristoph Engelhardt
Christoph Engelhardt
VCValérie Malfroy Camine
Valérie Malfroy Camine
DIDavid Ingram
David Ingram
PMPhilippe Müllhaupt
Philippe Müllhaupt
AFAlain Farron
Alain Farron
ATAlexandre Terrier
Alexandre Terrier
The estimation of muscle forces in musculoskeletal shoulder models is still controversial. Two different methods are widely used to solve the indeterminacy of the system: electromyography (EMG)-based methods and stress-based methods. The goal of this work was to evaluate the influence of these two methods on the prediction of muscle forces, glenohumeral load and joint stability after total shoulder arthroplasty. An EMG-based and a stress-based method were implemented into the same musculoskeletal shoulder model. The model replicated the glenohumeral joint after total shoulder arthroplasty. It contained the scapula, the humerus, the joint prosthesis, the rotator cuff muscles supraspinatus, subscapularis and infraspinatus and the middle, anterior and posterior deltoid muscles. A movement of abduction was simulated in the plane of the scapula. The EMG-based method replicated muscular activity of experimentally measured EMG. The stress-based method minimised a cost function based on muscle stresses. We compared muscle forces, joint reaction force, articular contact pressure and translation of the humeral head. The stress-based method predicted a lower force of the rotator cuff muscles. This was partly counter-balanced by a higher force of the middle part of the deltoid muscle. As a consequence, the stress-based method predicted a lower joint load (16% reduced) and a higher superior–inferior translation of the humeral head (increased by 1.2 mm). The EMG-based method has the advantage of replicating the observed cocontraction of stabilising muscles of the rotator cuff. This method is, however, limited to available EMG measurements. The stress-based method has thus an advantage of flexibility, but may overestimate glenohumeral subluxation.

8 March 2017 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
VCValérie Malfroy Camine
Valérie Malfroy Camine
ATAlexandre Terrier
Alexandre Terrier
DPDominique Pioletti
Dominique Pioletti
Micromotion-induced interstitial fluid flow at the bone-implant interface has been proposed to play an important role in aseptic loosening of cementless implants. High fluid velocities are thought to promote aseptic loosening through activation of osteoclasts, shear stress induced control of mesenchymal stem cells differentiation, or transport of molecules. In this study, our objectives were to characterize and quantify micromotion-induced fluid flow around a cementless femoral stem using finite element modeling. With a 2D model of the bone-implant interface and full-factorial design, we first evaluated the relative influence of material properties, and bone-implant micromotion and gap on fluid velocity. Transverse sections around a femoral stem were built from computed tomography images, while boundary conditions were obtained from experimental measurements on the same femur. In a second step, a 3D model was built from the same data-set to estimate the shear stress experienced by cells hosted in the peri-implant tissues. The full-factorial design analysis showed that local micromotion had the most influence on peak fluid velocity at the interface. Remarkable variations in fluid velocity were observed in the macrostructures at the surface of the implant in the 2D transverse sections of the stem. The 3D model predicted peak fluid velocities extending up to 2.2 mm/s in the granulation tissue and to 3.9 mm/s in the trabecular bone. Peak shear stresses on the cells hosted in these tissues ranged from 0.1 to 12.5 Pa. These results offer insight into mechanical stimuli encountered at the bone-implant interface.

31 July 2015 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
VCV. M. Camine
V. M. Camine
HRH. Rüdiger
H. Rüdiger
DPDominique Pioletti
Dominique Pioletti
ATAlexandre Terrier
Alexandre Terrier
(2015). Distribution of gap and micromotion during compressive loading around a cementless femoral stem. Computer Methods in Biomechanics and Biomedical Engineering: Vol. 18, French Society of Biomechanics, pp. 1896-1897.