Subrat Kumar Barik

Subrat Kumar Barik

Auto-generated profile, based on publicly available information

Subrat Kumar Barik

Kalinga Institute of Industrial Technology (KIIT) Deemed to be University 1 , Bhubaneswar

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
PDP.K. Dash
P.K. Dash
MPMalhar Padhee
Malhar Padhee
SBS.K. Barik
S.K. Barik

14 September 2021 in Journal of The Institution of Engineers (India): Series B
Verified
Journal Article
Closed access
PDF file
Bibhu Prasad GanthiaBibhu Prasad Ganthia
Bibhu Prasad Ganthia
SBSubrat Kumar Barik
Subrat Kumar Barik

1 July 2014 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
PDP. K. Dash
P. K. Dash
SBS. K. Barik
S. K. Barik
RPR. K. Patnaik
R. K. Patnaik

1 October 2015
Verified
Conference Paper
Closed access
SCSheetal Chandak
Sheetal Chandak
SDSnehamoy Dhar
Snehamoy Dhar
SBS K Barik
S K Barik
This paper presents a new study on active islanding detection method for grid connected photovoltaic (PV) based voltage source converter (VSC) system. The VSC system is basically controlled by positive sequence P-Q loop, where point of common coupling (PCC) power components are measured parameters. But during grid disconnection an islanding detection loop is further implemented with existing control, based on negative sequence voltage ( neg dq V , ) at PCC. The threshold for the feedback sequence voltage is determined to maintain a negligible non detection zone (NDZ) and to avoid false detection during other power quality issues. Worst case scenario is considered by implementing a PV based VSC system from IEEE UL 1741 standard. Performance of the proposed islanding detection loop is investigated in MATLAB/ Simulink environment. The efficient detection of islanding with less than a cycle Run on time is ensured by the result analysis, where no significant effect in power quality during normal operating condition has been maintained.

2 October 2015 in Australian Journal of Electrical and Electronics Engineering
Verified
Journal Article
Closed access
SBS. K. Barik
S. K. Barik
PDP. K. Dash
P. K. Dash
SDS. Dhar
S. Dhar
A new direct power control formulation for the voltage source converter (VSC) in a grid-connected photovoltaic (PV) array is discussed in this paper. Instead of controlling the direct- and quadrature-axis currents of the VSC through the use of a phase-locked loop system (PLL), the instantaneous real- and reactive-power components are used as control variables. This approach, therefore, does not take into account the unmodelled dynamics of the PLL resulting in a robust control of the active, reactive powers while maintaining the photovoltaic (PV) array voltage at a constant value. Further, the stability of the grid-connected PV array is enhanced by designing a Lyapunov’s function-based finite-time non-linear reactive power and dc-link voltage controller, which essentially uses the terminal sliding mode approach. To prove the robustness of the proposed approach, several system disturbances like changes in solar insolation and active and reactive power references, islanding conditions, converter parametric changes, and faults on the converter and inverter buses are considered. In all these cases, the new controller is found to enhance overall system stability in comparison to the inferior performance by the proportional-integral controller

26 May 2022
Verified
Conference Paper
Closed access
SPSudhansu Bhusan Pati
Sudhansu Bhusan Pati
SBSubrat Kumar Barik
Subrat Kumar Barik
SKSubhasri Kundu
Subhasri Kundu
RDRitesh Dash
Ritesh Dash
ABAdithya Ballajhi
Adithya Ballajhi
Power electronic best components are most sensitive to variation in voltage and current. therefore these components when connected to a DC microgrid needs more attention and protection against a different type of circuit faults like short circuit and open circuit condition. During short circuit condition the flow of heavy current will damage the electronic devices and thereby in order to achieve the protection these electronic devices may trip themselves. sudden tripping of the devices will have an adverse negative impact on the DC microgrid. This paper presents a new ANN-enabled bat algorithm to detect the DC fault and to isolate the fault from the rest part of the system. Matlab simulink based model has been developed to test the prototype and to compare the ANN enabled bat algorithm with other algorithm for comparing the efficiency of the proposed algorithm.