Joao Luis Toste Azevedo

Joao Luis Toste Azevedo

Auto-generated profile, based on publicly available information

Joao Luis Toste Azevedo

Technical University of Lisbon; Dep. Eng. Mecanica, Instituto Superior Técnico, Av. Rovisco Pais, 1049-001 Lisboa, Portugal

Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2005 in Biomass and Bioenergy
Verified
Journal Article
Closed access
CSChangdong Sheng
Changdong Sheng
JAJ.L.T. Azevedo
J.L.T. Azevedo

1 January 2014 in Fuel
Verified
Journal Article
Closed access
GWGongliang Wang
Gongliang Wang
RSR.B. Silva
R.B. Silva
JAJ.L.T. Azevedo
J.L.T. Azevedo
SMS. Martins-Dias
S. Martins-Dias
Mário CostaMário Costa
Mário Costa

30 July 2007 in Combustion Science and Technology
Verified
Journal Article
Closed access
Mário CostaMário Costa
Mário Costa
JAJ. L. T. Azevedo
J. L. T. Azevedo
Measurements have been performed in a 300 MWe, front-wall-fired, pulverized-coal, utility boiler. This boiler was retrofitted with boosted over fire air injectors that allowed the operation of the furnace under deeper staging conditions. New data are reported for local mean gas species concentration of O2, CO, CO2, NOx, gas temperatures and char burnout measured at several ports in the boiler including those in the main combustion and staged air regions. Comparisons of the present data with our previous measurements in this boiler, prior to the retrofitting with the new over fire system, show lower O2 and higher CO concentrations for the new situation as a consequence of the lower stoichiometry in the main combustion zone associated with the present boiler operating condition. Consistently, the measured mean NOx concentrations in the main combustion zone are now lower than those obtained previously, yielding emissions below 500 mg/Nm3@6%O2. Finally, the measured values of particle burnout at the furnace exit are acceptable being those measured in the main combustion zone comparable with those obtained with the conventional over fire system.

1 January 2002 in Proceedings of the Combustion Institute
Verified
Journal Article
Closed access
CSChandong Sheng
Chandong Sheng
JAJ.L.T. Azevedo
J.L.T. Azevedo

28 July 2004 in Biomass and Bioenergy
Verified
Journal Article
Closed access
JDJoão Dias
João Dias
Mário CostaMário Costa
Mário Costa
JAJ.L.T. Azevedo
J.L.T. Azevedo

1 February 2003 in Combustion Science and Technology
Verified
Journal Article
Closed access
Mário CostaMário Costa
Mário Costa
PSP. Silva
P. Silva
JAJ. L. T. Azevedo
J. L. T. Azevedo
Measurements have been performed in a 300-MW e , front-wall-fired, pulverized-coal utility boiler. New data are reported for local mean gas species concentrations of O 2 , CO, CO 2 , and NO x , gas temperatures, and charburnout measured at several ports in the boiler including those in the burner region. They complement previously obtained data in the same utility boiler before being retrofitted with low-NO x burners and over-fire air ports. During the current experimental work, a considerable effort was made to assure minimum variations on boiler operating conditions and coal chemical and particle size characteristics so that the data presented are especially useful for three-dimensional mathematical model evaluation and development. The main conclusions are as follows: (1) As compared with our previousmeasurementsin this boiler, prior to the retrofitting, the results show lower local mean O 2 and higher CO concentrations and temperatures in the boiler as a consequence of the lower stoichiometry in the main combustion zone, after retrofitting. (2) At the lower levels of the boiler the measured NO x concentrations are comparable with those obtained prior to the retrofitting but they are inferior at the upper levels of the boiler, which is consistent with the lower NO x emissions observed at the boiler exit, after retrofitting; specifically, 620 compared with 997 mg/Nm 3 prior to the retrofitting. (3) At the lower levels of the boiler, the high local mean char burnout values measured are due to the combined effects of significant presence of O 2 and relatively large residence times of the particles, while at the upper levels of the boiler the particles' residence time is the critical quantity influencing char burnout. (4) Results indicate that carbon isreleased at about the same rate as total coal mass release while both hydrogen and nitrogen are released more rapidly.