25 May 2016 in Journal of Physics: Conference Series
26 September 2016 in Physical Review E
We report on experiments irradiating isolated plastic spheres with a peak laser intensity of . With a laser focal spot size of full width half maximum (FWHM) the sphere diameter was varied between 520 nm and . Maximum proton energies of MeV are achieved for targets matching the focal spot size of in diameter or being slightly smaller. For smaller spheres the kinetic energy distributions of protons become nonmonotonic, indicating a change in the accelerating mechanism from ambipolar expansion towards a regime dominated by effects caused by Coulomb repulsion of ions. The energy conversion efficiency from laser energy to proton kinetic energy is optimized when the target diameter matches the laser focal spot size with efficiencies reaching the percent level. The change of proton acceleration efficiency with target size can be attributed to the reduced cross-sectional overlap of subfocus targets with the laser. Reported experimental observations are in line with 3D3V particle in cell simulations. They make use of well-defined targets and point out pathways for future applications and experiments.
21 October 2019 in IEEE Transactions on Radiation and Plasma Medical Sciences
The dosimetric advantages of ion therapy come at the cost of an increased sensitivity to range inaccuracies in the treatment planning and delivery stages. This prompts the development of imaging techniques capable of an accurate assessment of the relative stopping power (RSP). We investigate carbon ion imaging based on a prototype integration-mode detector working as range telescope. Experiments were conducted at the Heidelberg Ion-Beam Therapy Center with active pencil beam scanning. The aim of this work was to experimentally operate the imaging system in low-dose regimes. Therefore, an adjustment of the synchronization mechanism between beam delivery and data acquisition was required. Different from previous studies, this work investigated unexplored dosimetric scenarios and faced the related technological challenges. Radiographic and tomographic images of two tissue-equivalent phantoms were acquired and the image quality was evaluated. Relying on dedicated signal processing to solve the range mixing problem, the tomographic images showed an RSP accuracy of better than 0.6%. The presented study evaluates the imaging performance with low dose exposure, focusing on the technological requirements and pointing out the current limitations. Hence, this work supports the development of upgraded integration-mode ion imaging systems for reducing range uncertainties in particle therapy.