Background: Nonobstructive general angioscopy (NOGA) can identify vulnerable plaques in the aortic lumen that serve as potential risk factors for cardiovascular events such as embolism. However, the association between computed tomography (CT) images and vulnerable plaques detected on NOGA remains unknown. Methods and Results: We investigated 101 patients (67±11 years; women, 13.8%) who underwent NOGA and contrast‐enhanced CT before or after 90 days in our hospital. On CT images, the aortic wall thickness, aortic wall area (AWA), and AWA in the vascular area were measured at the thickest point from the 6th to the 12th thoracic vertebral levels. Furthermore, the association between these measurements and the presence or absence of NOGA‐derived aortic plaque ruptures (PRs) at the same vertebral level was assessed. NOGA detected aortic PRs in the aortic lumens at 145 (22.1%) of the 656 vertebral levels. The presence of PRs was significantly associated with greater aortic wall thickness (3.3±1.7 mm versus 2.1±1.2 mm), AWA (1.33±0.68 cm 2 versus 0.89±0.49 cm 2 ), and AWA in the vascular area (23.2%±9.3% versus 17.2%±7.6%) ( P <0.001 for all) on the CT scans compared with the absence of PRs. The frequency of PRs significantly increased as the aortic wall thickness increased. Notably, a few NOGA‐derived PRs were detected on CT in near‐normal intima. Conclusions: The presence of NOGA‐derived PRs was strongly associated with increased aortic wall thickness, AWA, and AWA in the vascular area, measured using CT. NOGA can detect PRs in the intima that appear almost normal on CT scans.
Stent fracture is one of the complications of drug-eluting stent implantation. An 84-year-old man underwent coronary angiography for unstable angina. He had diffuse severe stenosis and calcified plaque in the left anterior descending artery and underwent percutaneous coronary intervention (PCI) in the left anterior descending artery for severe stenosis with chest pain. Thereafter, two subsequent stent fractures occurred, so the patient underwent another PCI to cover them. However, a stent fracture was found again one year later. The patient was asymptomatic and PCI was avoided due to the risk of further stent fracture. When a stent fracture occurs, it is important to provide appropriate treatment according to the anatomical findings of the vessel, symptoms and the presence of ischemia.
2 May 2024 in European Heart Journal - Case Reports
Retinal artery occlusion (RAO) typically occurs as a result of embolization from various potential sources including the ipsilateral internal carotid artery, aortic arch, and the heart. However, direct visualization of the embolic source is uncommon.
17 November 2022 in Journal of Interventional Cardiology
Background. The effect of left subclavian artery tortuosity during percutaneous coronary intervention (PCI) in patients with acute coronary syndrome (ACS) remains unclear. Methods. Of 245 ACS patients (from November 2019 and May 2021), 79 who underwent PCI via a left radial approach (LRA) were included. We measured the angle of the left subclavian artery in the coronal view on CT imaging as an indicator of the tortuosity and investigated the association between that angle and the clinical variables and procedural time. Results. Patients with a left subclavian artery angle of a median of <70 degrees (severe tortuosity) were older (75.4 ± 11.7 vs. 62.9 ± 12.3 years, ) and had a higher prevalence of female sex (42.1% vs. 14.6%, ), hypertension (94.7% vs. 75.6%, ), and subclavian artery calcification (73.7% vs. 34.2%, ) than those with that ≥70 degrees. The left subclavian artery angle correlated negatively with the sheath cannulation to the first balloon time (ρ = −0.51, ) and total procedural time (ρ = −0.32, ). A multiple linear regression analysis revealed that the natural log transformation of the sheath insertion to first balloon time was associated with a subclavian artery angle of <70 degrees (β = 0.45, ). Conclusion. Our study showed that lower left subclavian artery angles as a marker of the tortuosity via the LRA were strongly associated with a longer sheath insertion to balloon time and subsequent entire procedure time during the PCI.