Nagaraju Konda

Nagaraju Konda

Auto-generated profile, based on publicly available information

Nagaraju Konda

School of Medical Sciences, Science Complex, University of Hyderabad, C.R Rao Road, Telangana, 500046 Gachibowli, Hyderabad, India

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
PKParthasarathi Kalaiselvan
Parthasarathi Kalaiselvan
DDDebarun Dutta
Debarun Dutta
FBFaiza Bhombal
Faiza Bhombal
NKNagaraju Konda
Nagaraju Konda
PVPravin Krishna Vaddavalli
Pravin Krishna Vaddavalli
Mark WillcoxMark Willcox
Mark Willcox

14 January 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
PKParthasarathi Kalaiselvan
Parthasarathi Kalaiselvan
DDDebarun Dutta
Debarun Dutta
NKNagaraju V. Konda
Nagaraju V. Konda
SSSavitri Sharma
Savitri Sharma
Naresh KumarNaresh Kumar
Naresh Kumar
Mark WillcoxMark Willcox
Mark Willcox
A clinical study of antimicrobial contact lenses containing the cationic peptide Mel4 was conducted. The few adverse events that occurred with this lens occurred on or after 13 nights of wear. The current study examined whether the Mel4 contact lenses lost activity during wear and the mechanism of this loss. Participants wore contact lenses for up to 13 nights. Lenses were tested for their ability to reduce the adhesion of Pseudomonas aeruginosa and Staphylococcus aureus. The amount of protein and lipid extracted from lenses was measured. The ability of trypsin to affect the antimicrobial activity of Mel4-coated contact lenses was measured. Mel4-coated contact lenses lost their antimicrobial activity at six nights of wear for both bacteria. The amount of lipids (13 ± 11 vs. 21 ± 14 μg/lens at 13 nights wear) and proteins (8 ± 4 vs. 10 ± 3 mg/lens at 13 nights of wear) extracted from lenses was not different between Mel4-coated and uncoated lenses, and was not different after three nights when antimicrobial activity was maintained and thirteen nights when they had lost activity (lipid: 25 ± 17 vs. 13 ± 11, p = 0.2; protein: 8 ± 1 vs. 8 ± 4 mg/lens, p = 0.4). Trypsin digestion eliminated the antimicrobial activity of Mel4-coated lenses. In summary, Mel4-coated contact lenses lost antibacterial activity at six nights of wear, and the most likely reason was proteolytic digestion of the peptide. Future studies will design and test proteolytically stable peptide mimics as coatings for contact lenses.

1 March 2025 in Clinical Optometry
Verified
Journal Article
Open access
PDF file
AKAnantha Krishnan
Anantha Krishnan
ADAnanya Dutta
Ananya Dutta
ASAlok Srivastava
Alok Srivastava
NKNagaraju Konda
Nagaraju Konda
RPRuby Kala Prakasam
Ruby Kala Prakasam
With the global shortage of eye care professionals and the increasing burden of vision impairment, particularly in low- and middle-income countries, there is an urgent need for innovative solutions to bridge gaps in eye care services. Advances in artificial intelligence (AI) over recent decades have significantly impacted healthcare, including the field of optometry. When integrated into optometric workflows, AI has the potential to streamline decision-making processes and enhance system efficiency. To realize this potential, it is essential to develop AI models that can improve each stage of the patient care workflow, including screening, detection, diagnosis, and management. This review explores the application of AI in optometry, focusing on its potential to optimize various aspects of patient care. We examined AI models across key areas in optometry. Our analysis considered crucial parameters, including model selection, sample sizes for training and validation, evaluation metrics, and the explainability of the models. This comprehensive review identified both the strengths and weaknesses of existing AI models. The majority of image-based studies utilized CNN or transfer learning models, while clinical data-based studies primarily employed RF, SVM, and XGBoost. In general, AI models trained on large datasets achieved higher accuracy. However, many optometry-focused models faced limitations due to insufficient sample sizes— 28% of studies were trained on fewer than 500 samples, 18% used fewer than 200 samples, and over half validated their models on fewer than 500 samples, with 38% validating on fewer than 200. Additionally, some studies that used the same data for both training and validation experienced overfitting, leading to reduced accuracy. Notably, 20% of the included studies reported accuracy below 80%, limiting their practical applicability in clinical settings. This review provides optometrists with valuable insights into the strengths and weaknesses of AI models in the field, aiding in their informed implementation in clinical settings.

3 January 2022 in Antibiotics
Verified
Journal Article
Open access
PDF file
PKParthasarathi Kalaiselvan
Parthasarathi Kalaiselvan
DDDebarun Dutta
Debarun Dutta
NKNagaraju Konda
Nagaraju Konda
PVPravin Krishna Vaddavalli
Pravin Krishna Vaddavalli
SSSavitri Sharma
Savitri Sharma
Mark WillcoxMark Willcox
Mark Willcox
(1) Purpose: This study aimed to investigate the effects of Mel4 antimicrobial contact lenses (MACL) on the ocular surface and comfort during extended wear. (2) Methods: A prospective, randomised, double-masked, contralateral clinical trial was conducted with 176 subjects to evaluate the biocompatibility of contralateral wear of MACL. The wearing modality was 14-day extended lens wear for three months. The participants were assessed at lens dispensing, after one night, two weeks, one month and three months of extended wear and one month after study completion. (3) Results: There were no significant differences (p > 0.05) in ocular redness or palpebral roughness between Mel4 and control eyes at any of the study visits. There was no significant difference (p > 0.05) in corneal staining between Mel4 and control eyes. There were no significant differences in front surface wettability or deposits or back surface debris (p > 0.05). No statistically significant differences (p > 0.05) were found in comfort, dryness, CLDEQ-8 scores lens or edge awareness. There was no evidence for delayed reactions on the ocular surface after cessation of lens wear. (4) Conclusion: The novel MACLs showed similar comfort to control lenses and were biocompatible during extended wear. Thus, these lenses were compatible with the ocular surface.

14 July 2022 in Experimental Eye Research
Verified
Journal Article
Closed access
AFAsra Fatima
Asra Fatima
PVPavani Vadla
Pavani Vadla
NKNagaraju Konda
Nagaraju Konda

20 November 2022 in Pathogens
Verified
Journal Article
Open access
PDF file
NKNagaraju Konda
Nagaraju Konda
SCSubhabrata Chakrabarti
Subhabrata Chakrabarti
PGPrashant Garg
Prashant Garg
Mark WillcoxMark Willcox
Mark Willcox
Background: To examine the relationship between single-nucleotide polymorphisms (SNPs) in interleukin (IL) genes and keratitis and its clinical manifestations. Methods: SNPs in IL1B, IL6, CXCL8, IL10, and IL12B were analysed. Differences in frequencies of alleles, genotypes and haplotypes between cases and controls as well as associations between SNPs and clinical variables were calculated by χ2 tests with odds ratios. Results: The minor homologous genotype in IL1B rs16944 (p = 0.036; odds ratio (OR) = 2.063, 95% confidence interval (CI): 1.048–4.061) and CXCL8 rs4073 (p = 0.041; OR = 0.463, 95% CI: 0.224–0.956) and the heterologous genotypes in IL6 rs1800795 (p = 0.046; OR = 0.563, 95% CI: 0.326–0.972) and IL12B rs2569254 (p = 0.0446; OR = 0.557, 95% CI: 0.314–0.989) or rs730691 (p = 0.0051; OR = 0.451, 95% CI: 0.260–0.784) were associated with keratitis. The minor genotype of rs16944 was associated with severe infection (p = 0.046). The heterologous genotype in rs2569254 was associated with hospital admission, photophobia, and mode of contact lens wear (p ≤ 0.041). The heterologous genotype in rs730691 was associated with blurred vision, discharge, anterior chamber reaction, and mode of wear (p ≤ 0.047). Conclusions: This study demonstrates that SNPs in IL1B and CXCL8 are associated with risk of developing keratitis. The study also found relationships between SNPs and clinical measures of keratitis. The potential for ethnic differences in frequency of SNPs and their association with keratitis should be followed up using different populations.