As a wear particle detection technology for machinery, electrostatic monitoring has broad application prospects However, there is currently a lack of a comprehensive method for achieving precise wear particle detection through electrostatic signals. This study proposes a wear particle detection method based on coaxial array electrostatic probes and a VMD-SR-DTW algorithm model. Firstly, a joint signal processing model is constructed using Variational Mode Decomposition (VMD) and Sparse Representation (SR) to reduce noise interference and enhance the signals triggered by wear particles. Furthermore, an algorithm model based on sliding windows and Dynamic Time Warping (DTW) is developed by utilizing the multi-channel signals from the coaxial array electrostatic sensor. The overall algorithm flow is analyzed in detail. Simulations and experiments are conducted to validate the effectiveness of the proposed method. The results demonstrate that the method effectively detects the signal pulses triggered by wear particles and provides a reliable approach for the engineering application of online monitoring.
Heavy equipment gear transmission system require monitoring of wear particles in lubricating oil to assess the degree of wear and predict failure. Compared to the traditional detection method, electrostatic sensor is an innovative online sensor for wear particle monitoring due to its high sensitivity and strong capability of early fault warning. This study presents a new spiral-shaped probe electrostatic sensor (S.P.E.S) and derives an analytical mathematical model of point charges on a spiral-shaped probe based on the physical model. To obtain a deeper understanding of the spiral-shaped probe, a finite element model was developed by using COMSOL software to explore the sensing characteristics and spatial static sensitivity of the spiral probe. Furthermore, experimental studies were conducted to investigate the dynamic sensitivity. The findings indicate that the sensitivity distribution of SPES is asymmetric due to the asymmetric structure of the probe. The simulation analysis and experimental provide a scientific basis for the design of spiral-probe sensor.