Fan Pu

Fan Pu

Auto-generated profile, based on publicly available information

Fan Pu

School of Materials Science and Engineering, East China University of Science and Technology, Mei Long Road 130, Shanghai 200237, P.R. China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2014 in Carbon
Verified
Journal Article
Closed access
MZMin Zhou
Min Zhou
FPFan Pu
Fan Pu
ZWZhao Wang
Zhao Wang
SGShiyou Guan
Shiyou Guan

10 April 2013 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
MZMin Zhou
Min Zhou
TCTingwei Cai
Tingwei Cai
FPFan Pu
Fan Pu
HCHao Chen
Hao Chen
ZWZhao Wang
Zhao Wang
SGShiyou Guan
Shiyou Guan

3 December 2018 in The Analyst
Verified
Journal Article
Closed access
PDF file
FPFan Pu
Fan Pu
SCSpencer Chiang
Spencer Chiang
WZWenpeng Zhang
Wenpeng Zhang
ZOZheng Ouyang
Zheng Ouyang
Direct sampling mass spectrometry enables high-performance clinical analysis, such as imaging, drug monitoring and point-of-care testing.

20 May 2013 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
MZMin Zhou
Min Zhou
FPFan Pu
Fan Pu
ZWZhao Wang
Zhao Wang
TCTingwei Cai
Tingwei Cai
HCHao Chen
Hao Chen
SGShiyou Guan
Shiyou Guan
Improving the Li storage properties of a Si negative electrode is of great significance for Li-ion batteries. A major challenge is to fabricate Si-based active materials with good electronic conduction and structural integrity in the process of discharging and charging. In this study, novel Si nanoparticles–graphene composites have been synthesized by hybrid electrostatic assembly between positively charged aminopropyltriethoxysilane modified Si nanoparticles and negatively charged graphene oxide, followed by thermal reduction. Commercially available Si nanoparticles are well embedded and uniformly dispersed into the graphene sheets, and the typically wrinkled graphene sheets form a network and cover the highly dispersed Si nanoparticles well. No any obvious aggregation of the Si nanoparticles can be found and many nanospaces exist around the Si nanoparticles, which provide buffering spaces needed for volume changes of Si nanoparticles during insertion/extraction of Li. High capacity and long cycle life (822 mA h g−1 after 100 cycles at a current density of 0.1 A g−1) have been realized in the novel Si nanoparticles–graphene composites for Li-ion batteries. The excellent electrochemical performance is ascribed to the uniform distribution of Si nanoparticles and graphene, which effectively prevents aggregation and pulverization of Si nanoparticles, keeps the overall electrode highly conductive, and maintains the stability of the structure.

21 September 2022 in Analytical Chemistry
Verified
Journal Article
Open access
FPFan Pu
Fan Pu
SUScott A. Ugrin
Scott A. Ugrin
ARAndrew J. Radosevich
Andrew J. Radosevich
DCDavid Chang-Yen
David Chang-Yen
JSJames W. Sawicki
James W. Sawicki
JWJon D. Williams
Jon D. Williams
Mass spectrometry (MS) is the primary analytical tool used to characterize proteins within the biopharmaceutical industry. Electrospray ionization (ESI) coupled to liquid chromatography (LC) is the current gold standard for intact protein analysis. However, inherent speed limitations of LC/MS prevent analysis of large sample numbers (>1000) in a day. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI-MS), an ambient ionization MS technology, has recently been established as a platform for high-throughput small molecule analysis. Here, we report the applications of such a system for the analysis of intact proteins commonly performed within the drug discovery process. A wide molecular weight range of proteins 10-150 kDa was detected on the system with improved tolerance to salts and buffers compared to ESI. With high concentrations and model proteins, a sample rate of up to 22 Hz was obtained. For proteins at low concentrations and in buffers used in commonly employed assays, robust data at a sample rate of 1.5 Hz were achieved, which is ∼22× faster than current technologies used for high-throughput ESI-MS-based protein assays. In addition, two multiplexed plate-based high-throughput sample cleanup methods were coupled to IR-MALDESI-MS to enable analysis of samples containing excessive amounts of salts and buffers without fully compromising productivity. Example experiments, which leverage the speed of the IR-MALDESI-MS system to monitor NISTmAb reduction, protein autophosphorylation, and compound binding kinetics in near real time, are demonstrated.

21 November 2019 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
HBHannah Marie Brown
Hannah Marie Brown
FPFan Pu
Fan Pu
MDMahua Dey
Mahua Dey
JMJames Miller
James Miller
MSMitesh V. Shah
Mitesh V. Shah
RCR. Graham Cooks
R. Graham Cooks