Lukas B. Gromann

Lukas B. Gromann

Auto-generated profile, based on publicly available information

Lukas B. Gromann

Department of Physics, Chair of Biomedical Physics, Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LGLukas B. Gromann
Lukas B. Gromann
FMFabio De Marco
Fabio De Marco
KWKonstantin Willer
Konstantin Willer
PNPeter B. Noël
Peter B. Noël
KSKai Scherer
Kai Scherer
JHJulia Herzen
Julia Herzen
X-ray chest radiography is an inexpensive and broadly available tool for initial assessment of the lung in clinical routine, but typically lacks diagnostic sensitivity for detection of pulmonary diseases in their early stages. Recent X-ray dark-field (XDF) imaging studies on mice have shown significant improvements in imaging-based lung diagnostics. Especially in the case of early diagnosis of chronic obstructive pulmonary disease (COPD), XDF imaging clearly outperforms conventional radiography. However, a translation of this technique towards the investigation of larger mammals and finally humans has not yet been achieved. In this letter, we present the firstin-vivoXDF full-field chest radiographs (32 × 35 cm2) of a living pig, acquired with clinically compatible parameters (40 s scan time, approx. 80 µSv dose). For imaging, we developed a novel high-energy XDF system that overcomes the limitations of currently established setups. Our XDF radiographs yield sufficiently high image quality to enable radiographic evaluation of the lungs. We consider this a milestone in the bench-to-bedside translation of XDF imaging and expect XDF imaging to become an invaluable tool in clinical practice, both as a general chest X-ray modality and as a dedicated tool for high-risk patients affected by smoking, industrial work and indoor cooking.

24 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KSKai Scherer
Kai Scherer
AYAndre Yaroshenko
Andre Yaroshenko
DBDeniz Ali Bölükbas
Deniz Ali Bölükbas
LGLukas B. Gromann
Lukas B. Gromann
KHKatharina Hellbach
Katharina Hellbach
JHJulia Herzen
Julia Herzen
Accounting for about 1.5 million deaths annually, lung cancer is the prevailing cause of cancer deaths worldwide, mostly associated with long-term smoking effects. Numerous small-animal studies are performed currently in order to better understand the pathogenesis of the disease and to develop treatment strategies. Within this letter, we propose to exploit X-ray dark-field imaging as a novel diagnostic tool for the detection of lung cancer on projection radiographs. Here, we demonstrate in living mice bearing lung tumors, that X-ray dark-field radiography provides significantly improved lung tumor detection rates without increasing the number of false-positives, especially in the case of small and superimposed nodules, when compared to conventional absorption-based imaging. While this method still needs to be adapted to larger mammals and finally humans, the technique presented here can already serve as a valuable tool in evaluating novel lung cancer therapies, tested in mice and other small animal models.

8 February 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KHKatharina Hellbach
Katharina Hellbach
ABAndrea Baehr
Andrea Baehr
FMFabio De Marco
Fabio De Marco
KWKonstantin Willer
Konstantin Willer
LGLukas B. Gromann
Lukas B. Gromann
MRMaximilian F. Reiser
Maximilian F. Reiser
The aim of this study was to assess the diagnostic value of x-ray dark-field radiography to detect pneumothoraces in a pig model. Eight pigs were imaged with an experimental grating-based large-animal dark-field scanner before and after induction of a unilateral pneumothorax. Image contrast-to-noise ratios between lung tissue and the air-filled pleural cavity were quantified for transmission and dark-field radiograms. The projected area in the object plane of the inflated lung was measured in dark-field images to quantify the collapse of lung parenchyma due to a pneumothorax. Means and standard deviations for lung sizes and signal intensities from dark-field and transmission images were tested for statistical significance using Student’s two-tailed t-test for paired samples. The contrast-to-noise ratio between the air-filled pleural space of lateral pneumothoraces and lung tissue was significantly higher in the dark-field (3.65 ± 0.9) than in the transmission images (1.13 ± 1.1; p = 0.002). In case of dorsally located pneumothoraces, a significant decrease (−20.5%; p > 0.0001) in the projected area of inflated lung parenchyma was found after a pneumothorax was induced. Therefore, the detection of pneumothoraces in x-ray dark-field radiography was facilitated compared to transmission imaging in a large animal model.

7 January 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
LGLukas B. Gromann
Lukas B. Gromann
DBDirk Bequé
Dirk Bequé
KSKai Scherer
Kai Scherer
KWKonstantin Willer
Konstantin Willer
LBLorenz Birnbacher
Lorenz Birnbacher
CCCristina Cozzini
Cristina Cozzini
Differential phase-contrast X-ray imaging using a Talbot-Lau interferometer has recently shown promising results for applications in medical imaging. However, reducing the applied radiation dose remains a major challenge. In this study, we consider the realization of a Talbot-Lau interferometer in a high Talbot order to increase the signal-to-noise ratio for low-dose applications. The quantitative performance of π and π/2 systems at high Talbot orders is analyzed through simulations, and the design energy and X-ray spectrum are optimized for mammography. It is found that operation even at very high Talbot orders is feasible and beneficial for image quality. As long as the X-ray spectrum is matched to the visibility spectrum, the SNR continuously increases with the Talbot order for π-systems. We find that the optimal X-ray spectra and design energies are almost independent of the Talbot order and that the overall imaging performance is robust against small variations in these parameters. Discontinuous spectra, such as that from molybdenum, are less robust because the characteristic lines may coincide with minima in the visibility spectra; however, they may offer slightly better performance. We verify this hypothesis by realizing a prototype system with a mean fringe visibility of above 40% at the seventh Talbot order. With this prototype, a proof-of-principle measurement of a freshly dissected breast at reasonable compression to 4 cm is conducted with a mean glandular dose of only 3 mGy but with a high SNR.

30 November 2023 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
FMFabio De Marco
Fabio De Marco
JAJana Andrejewski
Jana Andrejewski
TUTheresa Urban
Theresa Urban
KWKonstantin Willer
Konstantin Willer
LGLukas Gromann
Lukas Gromann
FPFranz Pfeiffer
Franz Pfeiffer
X-ray dark-field imaging enables a spatially-resolved visualization of ultra-small-angle X-ray scattering. Using phantom measurements, we demonstrate that a material’s effective dark-field signal may be reduced by modification of the visibility spectrum by other dark-field-active objects in the beam. This is the dark-field equivalent of conventional beam-hardening, and is distinct from related, known effects, where the dark-field signal is modified by attenuation or phase shifts. We present a theoretical model for this group of effects and verify it by comparison to the measurements. These findings have significant implications for the interpretation of dark-field signal strength in polychromatic measurements.